background image

                                                                                                                                                        

 10

2.  Installation of the unit 

 

 2.1  Suspension of the CDF 10 unit 

 
The wall suspension bar supplied with the unit is fixed to the wall and the dehumidifier is hung up on it. It is 
important to mount the unit in a horizontal position to secure correct outflow of the condensate water. 
 
The dehumidifier must be placed in a way that allows unimpeded air intake through the front and outlet through the 
grill on the sides. Be sure always to leave at least 100 mm free space around the unit for optimum operation. 
 
 
 

            

 

 
 
 
It is important that the dehumidifier is not installed near a source of heat as for example a radiator, and doors and 
windows must be kept closed when the dehumidifier is in function. 
 
                                                                                                            

2.2  Condensate outlet 

 
The condensate outlet is located at the bottom of the dehumidifier. The unit has a drain spigot intended for 
connection of a ½’’ flexible or fixed water connection. If  water drain through the wall is chosen, a suitable hole is 
made in the wall and the condensate hose is led out through this hole, before suspending the dehumidifier on the 
wall suspension bar. 
   
As an alternative a condensate pump can be fitted at the water outlet to pump the water to a drain. 
 
The placing of the condensate outlet is shown on the drawing below.       
                                                               

NOTE!  On the rear of the unit a cable binder protects the compressor 

during transport. This cable binder 

must

 be removed before 

suspension and power connection. 

Summary of Contents for CDF 10

Page 1: ...GES 8 13 DEUTSCH SEITE 14 20 FRANCAIS PAGES 21 27 Der tages forbehold for trykfejl og ndringer Dantherm can accept no responsibility for possible errors and changes Irrt mer und nderungen vorbehalten...

Page 2: ...control 10 3 Connection of power supply 11 4 Operation 11 4 1 LED indication Switch 11 4 2 Built in hygrostat 11 4 3 Defrosting 12 4 4 Safety circuit 12 4 5 Compressor control 12 5 Maintenance 12 5 1...

Page 3: ...ng turned into heat energy more heat is returned to the air than was previously extracted This extra heat corresponds to an approximate increase in temperature of 5 C The repeated circulation of air t...

Page 4: ...le a radiator and doors and windows must be kept closed when the dehumidifier is in function 2 2 Condensate outlet The condensate outlet is located at the bottom of the dehumidifier The unit has a dra...

Page 5: ...it dehumidifies The dehumidifier is switched on and off by the switch on the side 4 2 Built in hygrostat The dehumidifier is controlled by a built in hygrostat that is set to approx 50 RH When the hyg...

Page 6: ...rom overheating The unit will automatically start again when the room temperature is within the working range 4 5 Compressor control The number of compressor starting is limited by a 6 minutes timer w...

Page 7: ...erwards check the following 5 Check that the fan is running when the unit starts after 45 minutes 6 Check whether the condensor coil is dirty 7 Check whether the filter is dirty 8 Check whether the ro...

Page 8: ...vaporator Verdampfer vaporateur 3 Luftk let kondensator air cooled condensor luftgek hlter Kondensator condenseur air 4 Kapillarr r capillary tube Kapillarrohr tubes capillaires 5 T rfilter liquid lin...

Page 9: ...29 8 El diagram Wiring diagram Schaltplan Sch ma lectrique CDF 10 1 x 230V 50Hz...

Page 10: ...Designation Beschreibung D signation TS1 Kondensatorf ler Condenser sensor Kondensatorf hler Sonde du condenseur TS1 Fordamperf ler Evaporator sensor Verdampferf hler Sonde d vaporateur M2 Ventilator...

Page 11: ...31 CDF 10 1 x 230V 50Hz...

Page 12: ...teur basculant 18 084751 19 600990 Kondensatorflade Condensor Kondensator Condenseur 20 084752 21 516350 Hygrostat Hygrostat Hygrostat Hygrostat 22 293646 Holder for hygrostat Retainer for hygrostat H...

Page 13: ...33...

Page 14: ...34...

Page 15: ...35...

Page 16: ...36...

Reviews: