background image

                                                                                                                                                        

 32

CDF 10  -  1 x 230V / 50Hz 

 

Pos. Dantherm. 

no. 

Beskrivelse 

Designation 

Beschreibung 

Description 

084767 

Vægbeslag 

Wall suspension bar 

Wandkonsole 

Barre d’ancrage 

293647 

Kabinet kpl. 

Housing, cpl. 

Gehäuse, kpl. 

Carrosserie cpl. 

3 601933 

Kompressor 

Compressor 

Kompressor 

Compresseur 

3a 

510051 

Startrelæ 

Starting relay 

Startrelais 

Relais de démarrage 

3b 

510052 

Beskyttelse for relæ 

Overload protector for relay 

Schutz für Relais 

Protection du relais 

4 084766 

 

 

 

 

5 084753 

 

 

 

 

532480 

Ventilatormotor 

Fan motor 

Ventilatormotor 

Moteur de ventilateur 

532520 

Ventilatorvinge 

Fan blade 

Ventilatorflügel 

Ailette du ventilateur 

8 084764 

 

 

 

 

9 084765 

 

 

 

 

10 

517581 

Printkort 

Printed circuit board 

Printplatte 

Platine électronique 

11 

517599 

Diodeprint 

Diode print 

Diodenprint 

Platine de diode 

12 

605440 

Spole for magnetventil 

Coil for solenoid valve 

Spule für Magnetventil 

Bobine de la vanne magnétique 

13 605470 

Magnetventil 

Solenoid 

valve 

Magnetventil 

Vanne 

magnétique 

14 

517802 

Føler, metalnæse, 1150mm 

Sensor, metal nose, 1150 mm 

Fühler, Metallnase, 1150 mm 

Sonde, nez métallique, 1150 mm 

15 

517804 

Føler, 1250mm 

Sensor, 1250 mm 

Fühler, 1250 mm 

Sonde, 1250 mm 

16 084750 

 

 

 

 

17 515081 

Vippeafbryder 

Toggle 

switch 

Kippschalter 

Interrupteur 

basculant 

18 084751 

 

 

 

 

19 600990 

Kondensatorflade 

Condensor 

Kondensator 

Condenseur 

20 084752 

 

 

 

 

21 516350 

Hygrostat 

Hygrostat 

Hygrostat 

Hygrostat 

22 

293646 

Holder for hygrostat 

Retainer for hygrostat 

Halter für Hygrostat 

Support de l’hygrostat 

22a 

921343 

Skala for hygrostat 

Scale for hygrostat 

Skala für Hygrostat 

Cadran de l’hygrostat 

23 

541774 

Drejeknap 

Adjusting knob 

Drehknopf 

Bouton rotatif 

24 

607410 

Tørrefilter 

Liquid line drier 

Trockenfilter 

Filtre anti-humidité 

25 

435620 

Kapillarrør 

Capillary tube 

Kapillarrohr 

Tubes capillaires 

26 198332 

Fordamper 

Evaporator Verdampfer  Evaporateur 

27 

293645 

Drypbakke, kpl. 

Condensate tray, complete 

Kondensatschale, kpl. 

Bac à eau, cpl. 

28 

544150 

Afløbsstuds 

Drain spigot 

Ablaufstutzen 

Orifice d’écoulement 

29 

524890 

Tilslutningskabel 

Connection cable 

Anschlusskabel 

Câble de raccordement 

30 

540131 

Afstandsstykke 

Spacing piece 

Distanzrohr 

Pièce d’écartement 

31 

293644 

Front, kpl. 

Front panel, complete 

Deckplatte vorne, kpl. 

Tôle frontale, cpl. 

31a 

528117 

Skilt – Dantherm logo 

Label – Dantherm logo 

Aufkleber – Dantherm Logo 

Etiquette – Dantherm logo 

31b 

528627 

Skilt – CDF 10 

Label – CDF 10 

Aufkleber – CDF 10 

Etiquette – CDF 10 

31c 084771 

Filter 

Filter 

Filter 

Filtre 

32 527500 

Kontramøtrik 

Counter 

nut 

Gegenmutter 

Contre-écrou 

33 

526900 

Kabelforskruning 

Screwed cable entry 

Kabelverschraubung 

Raccord à vis pour le cable 

34 084772 

Isolering 

Insulation 

Isolierung 

Isolant 

 

Summary of Contents for CDF 10

Page 1: ...GES 8 13 DEUTSCH SEITE 14 20 FRANCAIS PAGES 21 27 Der tages forbehold for trykfejl og ndringer Dantherm can accept no responsibility for possible errors and changes Irrt mer und nderungen vorbehalten...

Page 2: ...control 10 3 Connection of power supply 11 4 Operation 11 4 1 LED indication Switch 11 4 2 Built in hygrostat 11 4 3 Defrosting 12 4 4 Safety circuit 12 4 5 Compressor control 12 5 Maintenance 12 5 1...

Page 3: ...ng turned into heat energy more heat is returned to the air than was previously extracted This extra heat corresponds to an approximate increase in temperature of 5 C The repeated circulation of air t...

Page 4: ...le a radiator and doors and windows must be kept closed when the dehumidifier is in function 2 2 Condensate outlet The condensate outlet is located at the bottom of the dehumidifier The unit has a dra...

Page 5: ...it dehumidifies The dehumidifier is switched on and off by the switch on the side 4 2 Built in hygrostat The dehumidifier is controlled by a built in hygrostat that is set to approx 50 RH When the hyg...

Page 6: ...rom overheating The unit will automatically start again when the room temperature is within the working range 4 5 Compressor control The number of compressor starting is limited by a 6 minutes timer w...

Page 7: ...erwards check the following 5 Check that the fan is running when the unit starts after 45 minutes 6 Check whether the condensor coil is dirty 7 Check whether the filter is dirty 8 Check whether the ro...

Page 8: ...vaporator Verdampfer vaporateur 3 Luftk let kondensator air cooled condensor luftgek hlter Kondensator condenseur air 4 Kapillarr r capillary tube Kapillarrohr tubes capillaires 5 T rfilter liquid lin...

Page 9: ...29 8 El diagram Wiring diagram Schaltplan Sch ma lectrique CDF 10 1 x 230V 50Hz...

Page 10: ...Designation Beschreibung D signation TS1 Kondensatorf ler Condenser sensor Kondensatorf hler Sonde du condenseur TS1 Fordamperf ler Evaporator sensor Verdampferf hler Sonde d vaporateur M2 Ventilator...

Page 11: ...31 CDF 10 1 x 230V 50Hz...

Page 12: ...teur basculant 18 084751 19 600990 Kondensatorflade Condensor Kondensator Condenseur 20 084752 21 516350 Hygrostat Hygrostat Hygrostat Hygrostat 22 293646 Holder for hygrostat Retainer for hygrostat H...

Page 13: ...33...

Page 14: ...34...

Page 15: ...35...

Page 16: ...36...

Reviews: