05776-1198 <90-00124>

21.

Remove the termination from the dB meter and verify a level of 0
dB at the front panel blue XMT LVL test points for both channels 1
and 2.

22.

Terminate the meter with 600 ohms and verify a level of +7 dB at
the front panel RCV DROP jack of channel 1.

23.

With the meter still terminated, verify the level at the front panel
RCV DROP jack of channel 2 is -40 dB or more negative.

24.

Move the signal generator to C2 pins 20 and 45.

25.

Move the level meter to C2 pins 19 and 45

26.

Verify a level of +7 dBm

27.

Remove the signal generator and dB meter.

28.

Using connector C2 connect the A18-05776-XX assembly to two
B11-46105-00 systems that are in the working in the terminal
mode. One will be connected to channel 1 and the other to
channel 2.

29.

On the C2 connector of the A18-05776-00 that is used to connect
to the terminal mode 46105 modules, jumper pins 12 to 37 and
11 to 36.

30.

Talk through the system in both directions and verify the module
works properly.

31.

Verify that the green LEDs on the front panel light steadily for the
channel(s) that you are using.  When a light is on, it means the
framing bit is being detected by the digital section of that channel
of the module, indicating synchronization of data transmitted to it.

32.

Operation of the 46105 module consists of talking through the sys-
tem in either direction. The front panel RCV SYNC LED for the
channel that you are using lights steadily if the data being received
is in synchronization with the transmitting unit.

33.

If the module is working in the repeater mode and the synchroniza-
tion signal is lost in either direction, the unit automatically reverts
to the terminal mode, allowing continued communications in the
direction from which the synchronization is still being received.
When synchronization is re-established, repeater operation re-
sumes. Verify that that a loss of a terminal from one direction has
no effect on the opposite direction of the system.

34.

With the Order Wires talking to one another, remove the handset
and hit the Touch Tone pad on the A18-05775-00 and verify that
the tones can be heard at the other OW sites.

35.

Hang up the handset.

36.

At the remote location, on the Channel 1 side of the 46105, remove
a handset and verify that C2 Pins 39 and 40 of the A18-05776-01
are closed.

ALIGNMENT PROCEDURES

CONTINUED

 . . .

Summary of Contents for B18-05776 Series

Page 1: ...ION OPERATION MANUAL 05776 1198 90 00124 B18 05776 XX UNIVERSAL ORDER WIRE ASSEMBLY About this Practice This practice has been reissued to Document B18 release with new M Lead Interface Module Update...

Page 2: ...unit DTMF signaling is only used to get access to the VNET interface to the PBX The unit is designed as a party line system so that a caller on the OW channel will simply speak into the handset and c...

Page 3: ...ne Interface 46105 Dual VF 64Kb Channel EQUIPMENT MOUNTING Install the shelf in an equipment rack using the hardware provided Refer to Fig 1 FIG 1 MOUNTING DIMENSIONS WIRING Wire the shelf as required...

Page 4: ...PAGE 4 05776 1198 90 00124 FIG 2 FUNCTIONAL SCHEMATIC 05776 SHELF INSTALLATION UPDATED...

Page 5: ...Tables A through C and Fig 4 through 6 to set the straps and switches on the modules TABLE A SWITCH AND STRAP SETTINGS 44118 BRIDGE NOTE All switches straps and levels are factory set UPDATED 1 2 3 4...

Page 6: ...for order wire applications 2 WIRE 4 WIRE DROP 4 Wire SIDETONE 4 Wire with sidetone 4 WIRE DROP RCV IMPEDANCE 600 ohms Ring Generator OPTION GP ALL RCV PAD OUT XMT PAD OUT IN PRIVACY OUT 4W Straps ho...

Page 7: ...are not in use Select this position when the channels are bridged together in the repeater mode BRDG switch also must be in the RPTR position STRAP XMT CLK RCV CLK 1 RCV DATA 1 XMT CLK 2 RCV CLK 2 RC...

Page 8: ...LLATION MODE E LEAD TERM RPTR NO YES LPBK 1 OFF ON LPBK 2 BRDG CHANNEL 2 CHANNEL 1 M LEAD 2 OFF ON DATA CLK CLK RCV RCV XMT NO NC TERM TTL TM T T TM T T TERM RPTR S101 S2 S1 T T L T E R M RCV DATA T T...

Page 9: ...00 ohm termination to the DROP RE CEIVE jack 6 Read 13 dBm Adjust the RECEIVE level control as required RCV PAD is set for 3 to 16 dBm range 7 When finished setting levels press the TEST RST button Th...

Page 10: ...nnected to the RJ 1 connector of the A18 05776 00 The RJ plug would connect as follows 17 Select the number one OW by pushing in the number one switch of the A18 05775 00 18 Remove the handset of the...

Page 11: ...INE RCV PORT 3 level control R38 for reading of 10 dBm 14 Move signal generator to the LINE RCV PORT 4 jack J7 15 Read distribution level on meter Adjust the LINE RCV PORT 4 level control R54 for read...

Page 12: ...d and it should read 16 dBm 30 Move the 1 KHz tone to Port 3 RCV input and verify that the tone can be seen at C1 Pins 27 and 2 at a 16 dBm level 31 Connect the level meter terminated to the summing d...

Page 13: ...L test points for channel 2 If the level is not correct adjust the front panel transmit potentiometer 11 Install a 600 ohm termination on the dB meter and connect the meter to the DROP RCV jack for ch...

Page 14: ...el s that you are using When a light is on it means the framing bit is being detected by the digital section of that channel of the module indicating synchronization of data transmitted to it 32 Opera...

Page 15: ...with the appropriate button selected for the OW that is going to be seized 3 The LED on the associated button on the 05775 will light indicating that the unit is seized 4 If the OW unit is equipped wi...

Page 16: ...24VDC Idle Full Load 48VDC Idle Full Load Heat Dissipation 24VDC Idle Full Load 48VDC Idle Full Load Physical Dimensions 19 23 Weight Operating Temperature Range VALUE 21 to 56 VDC 164 mA 174 mA 85 mA...

Page 17: ...05776 1198 90 00124 PAGE 17 NOTES...

Page 18: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...

Reviews: