background image

41096-0597 <90-00042>

 P

AGE

 11

6. Install the assembled unit into the rack.

7. Connect supply leads.

8. Connect input and/or output ports.

Connect the appropriate input and/or output ports on each order

wire (see the 00330 DTSS3A and subassembly documentation.)

9. Set the straps.

Refer to Table B and Fig. 4.

INSTALLATION

I

nitiate a call by pressing the desired channel push-button,

 lifting the handset (or plugging in a headset) and dialing the

desired station code. Answer an incoming call by pressing the

channel push-button below the flashing CALL LAMP LED and

lifting the handset (or plugging in a headset).
Monitor all three order wire channels by turning the ALL CHAN

SPEAKER VOLUME CONTROL clockwise until a sufficient

level is heard.
Monitor a single channel by pressing the desired SPEAKER

MONITOR CHAN SELECT push-button and turning the CHAN

SELECT SPEAKER VOLUME CONTROL clockwise until a

sufficient level is heard.
Reduce the level of other channel traffic by turning down the

ALL CHAN SPEAKER VOLUME CONTROL. A limit resistor

prevents other channel traffic from being completely turned off.

This limit resistor can be bypassed with a bypass strap.
Monitor two channels at once by pressing two SPEAKER MONI-

TOR CHANNEL SELECT push-buttons. When channel monitor-

ing is no longer desired, return to all-channel monitoring by

pressing and releasing the SPEAKER MONITOR CHANNEL

SELECT push-button(s).

OPERATION

Summary of Contents for 41096

Page 1: ...fields For more complete information on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1997 by Dantel Inc Dantel is a registered trademark o...

Page 2: ...nitor Panel with 3 DTSS3A Terminals 3 digit dialing A13 41096 05 Speaker Monitor Panel with 1 DTSS3A Terminal 6 digit dialing A13 41096 06 Speaker Monitor Panel with 2 DTSS3A Terminals 6 digit dialing...

Page 3: ...aker with amplifier Two volume controls A fuse A fuse alarm LED The control section includes A push button channel selector DTMF dial Handset Handset cradle Headset jacks Table A shows standard 41096...

Page 4: ...potentiometer This option allows the selected channel s to be monitored at a louder level The unselected channels are still available for monitoring at a quieter level A fuse and fuse alarm indicator...

Page 5: ...O 56VDC 10 VDC SPKR MON CHAN SELECT LAMP LAMP S3 4 1 2 5 6 3 4 1 2 5 4 1 2 5 R T T R 6 3 6 3 LAMP LAMP LAMP LAMP LAMP DIAL HEADSET J8 J9 4 1 4 1 A B 1 2 3 1 2 3 4 5 6 1 2 3 4 HANDSET JACK RCV XMT RCV...

Page 6: ...Order Wire terminals INSTALLING WITH DTSS3A ORDER WIRE TERMINALS When the 41096 Panel is purchased with DTSS3A Order Wire terminals the 41096 Panel comes with the terminals mounted and wired to the pa...

Page 7: ...ove mounting brackets Remove the mounting brackets from the order wire terminal s and replace them with the mounting brackets supplied with the 41096 panel Install the brackets in the flush mount posi...

Page 8: ...BRACKET ATTACH ANGLE POSITIONS INSTALLATION SIDE VIEW FRONT TOP VIEW FRONT 19 STANDARD MOUNT SIDE VIEW FRONT 19 FLUSH MOUNT TOP VIEW FRONT 23 STANDARD MOUNT TOP VIEW FRONT SIDE VIEW FRONT 23 FLUSH MOU...

Page 9: ...Table C Fig 4 and Fig 5 Use wire wrap terminals and leave the modular type telephone jacks available for connecting extensions Dress the wiring across the rear of the 41096 Panel and through the wire...

Page 10: ...CHANNEL 2 P3 1 P3 2 P3 3 P3 4 P3 5 P3 6 P1 3 P1 4 CHANNEL 3 P4 1 P4 2 P4 3 P4 4 P4 5 P4 6 P1 5 P1 6 TB1 1 TB1 3 TB1 2 TABLE C INTER PANEL WIRING FIG 5 WIRING DIAGRAM DTSS3A 41096 PANEL WIREWRAP TERMI...

Page 11: ...itor all three order wire channels by turning the ALL CHAN SPEAKER VOLUME CONTROL clockwise until a sufficient level is heard Monitor a single channel by pressing the desired SPEAKER MONITOR CHAN SELE...

Page 12: ...requency Response Input Impedance VALUE 21 to 56 VDC 75 mA 56 VDC 250 mA 56 VDC 14 3 BTU Hr 56 VDC 47 7 BTU Hr 56 VDC 4 lb 2 oz 8 lb 10 oz 13 lb 2 oz 17 lb 10 oz 17 1 4 W plus mounting hardware x 3 1...

Page 13: ...41096 0597 90 00042 PAGE 13 NOTES...

Page 14: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...