Dante DNA1982 Web Operation Manual Download Page 5

                                                                           

 

 

2

2222

 

Main Interface Introduction

Main Interface Introduction

Main Interface Introduction

Main Interface Introduction    

2.1

2.1

2.1

2.1

 

Log in 

Log in 

Log in 

Log in     

Open IE and input speed dome address in the address bar.  

For example, if your device IP is 192.168.1.108, then please input http:// 192.168.1.108 in IE address 

bar. See Figure 2-1. 

 

 

Figure 2-1 IE 

The login interface is shown as below. See Figure 2-2. 

Please input your user name and password.  

Default factory name is 

admin

 and password is 

admin

.  

Note: For security reasons, please modify your password after you first login. 

Input your IP 

address here 

Summary of Contents for DNA1982

Page 1: ...DNA1982 85 90 IP PTZ Domes Web Operations Manual Model Number DNA1982 DNA1985 DNA1990 Description IP D1 and MP PTZ Domes 18x 20 28x 36x Optical Zoom...

Page 2: ...stem Menu 5 2 5 Video Window Function Option 5 2 6 Video Window Setup 6 3 PTZ Control 8 4 Setup 12 4 1 Camera 12 4 1 1 Video 12 4 1 2 Audio 17 4 2 IVS 18 4 2 1 Global Setup 18 4 2 2 Scene Setup 19 4 2...

Page 3: ...0 4 6 System 61 4 6 1 General 61 4 6 2 Account 63 4 6 3 PTZ 67 4 6 4 Default 68 4 6 5 Import Export 69 4 6 6 Auto maintenance 70 4 6 7 Firmware update 70 4 7 Information 71 4 7 1 Version 71 4 7 2 Log...

Page 4: ...itor channel preview PTZ control system configuration alarm and etc Please follow the steps listed below for network connection Make sure the speed dome has connected to the network properly Speed dom...

Page 5: ...s in the address bar For example if your device IP is 192 168 1 108 then please input http 192 168 1 108 in IE address bar See Figure 2 1 Figure 2 1 IE The login interface is shown as below See Figure...

Page 6: ...b or not Please click OK button system can automatically install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether...

Page 7: ...Live Interface There are four sections Section 1 Encode setup bar Section 2 System menu Section 3 Window function option bar Section 4 Window adjust bar 2 3 2 3 2 3 2 3 Encode Setup Encode Setup Enco...

Page 8: ...e chapter 3 PTZ chapter 4 Setup chapter 5 Alarm chapter 6 Log out for detailed information Figure 2 6 System Menu 2 5 2 5 2 5 2 5 Video Window Function Option Video Window Function Option Video Window...

Page 9: ...ect in the specified area Please note you need to go to IVS Global setup to enable IVS function first See Chapter 4 2 1 Global Setup 2 6 2 6 2 6 2 6 Video Window Setup Video Window Setup Video Window...

Page 10: ...setup It is to adjust monitor video brightness Note All the operations here apply to WEB end only It is to adjust monitor video contrast ness It is to adjust monitor video saturation It is to adjust...

Page 11: ...System PTZ to set Here you can view direction keys speed zoom focus iris preset tour pan scan pattern aux close PTZ setup button and 3D positioning button See Figure 3 1 PTZ direction PTZ supports eig...

Page 12: ...igure 3 2 PTZ Control Interface Click PTZ set button the interface is shown as in Figure 3 3 You can click this icon to display or hide the PTZ control platform After click the icon 3D positioning but...

Page 13: ...to move the device to your desired location and then input preset value Click add button you have set one preset The preset value ranges from 1 to 80 It may vary due to different protocols Tour Input...

Page 14: ...record button in Figure 3 3 Now you have set one pattern Assistant The assistant items include BLC Digital zoom night vision camera brightness flip You can select one option and then click start or s...

Page 15: ...tion Main stream Bit stream type It includes general stream motion stream and alarm stream You can select different encode frame rates form different recorded events System supports active control fra...

Page 16: ...CBR Please note you can set video quality in VBR mode Recommended Bit Recommended bit rate value according to the resolution and frame rate you have set Bit Rate In CBR the bit rate here is a relative...

Page 17: ...esolutions You can select from the dropdown list For each resolution the recommended bit stream value is different Frame Rate PAL 1 25f s NTSC 1 30f s The frame rate may vary due to different resoluti...

Page 18: ...wo modes general schedule and Event activation Image size It is the same with the resolution of the main stream Quality It is to set the image quality There are six levels Interval It is to set snapsh...

Page 19: ...video window You can use the mouse to drag the time tile position Channel Title You can enable this function so that system overlays channel information in video window You can use the mouse to drag...

Page 20: ...lowing sheet for detailed information Parameter Function Audio enable Main stream Recorded file only contains video by default You need to check the audio box here to enable audio function Sub Extra s...

Page 21: ...l setup interface is shown as in Figure 4 6 Figure 4 6 Please refer to the following sheet for detailed information Parameter Function IVS track enable Check the box here to enable this IVS function A...

Page 22: ...tour function Track dealy After system recognized the tracing object it can delay a period of time to enable the alarm track Please note it is for panorama track mode only Track time You can set the...

Page 23: ...track speed for selected scene PTZ Click PTZ button to adjust scene position Speed It is to set PTZ movement speed The value ranges from 1 to 8 Limit track Check the box here to set limit track of cu...

Page 24: ...scene track interface is shown as in Figure 4 9 Figure 4 9 In Figure 4 9 click Add scene button you can set tour point during the scene tour process Move the mouse to the Scene name list you can selec...

Page 25: ...ted scene Rule enable Check the box here to enable the rule Rule name Move you mouse to the rule name column to set a name Rule type Move you mouse to the Rule type column to set the rule type The opt...

Page 26: ...Here you can set the alarm activation position of the target frame There are five options Centre Left centre Right centre Top centre Bottom centre Direction It is to set tripwire direction The option...

Page 27: ...24 Figure 4 13 4 2 3 2 Cross Warning Zone The cross warning zone interface is shown as in Figure 4 14 Figure 4 14...

Page 28: ...he zone System will not generate an alarm when the object amount in the zone is more than the threshold you set here Min target No It is for the In area option in the Detect action list item It is to...

Page 29: ...ion of the target frame There are five options Centre Left centre Right centre Top centre Bottom centre Direction It is to set cross perimeter direction The option includes From left to right From rig...

Page 30: ...on Here you can set the alarm activation amount System will not generate an alarm if the person amount is below the threshed you set here Min last time Here is to set the min time between the target i...

Page 31: ...of the target frame There are five options Centre Left centre Right centre Top centre Bottom centre Min last time It is to set the min time between the abandoned object occurrence and alarm activatio...

Page 32: ...ation position of the target frame There are five options Centre Left centre Right centre Top centre Bottom centre Min last time It is to set the min time between the missing object occurrence and ala...

Page 33: ...tion position of the target frame There are five options Centre Left centre Right centre Top centre Bottom centre Min last time It is to set the min time between the illegal parking occurrence and ala...

Page 34: ...arming zone Activate alarm position Here you can set the alarm activation position of the target frame There are five options Centre Left centre Right centre Top centre Bottom centre Sensitivity Here...

Page 35: ...that the device can output an alarm when alarm activation occurred Send e mail Check the box here so that the device can send out an email when alarm activation occurred Please note current function...

Page 36: ...he same time the error detect may become more Anti disturbance mode It is to control the random disturbance in the scene Backlight scene enable Check the box here so that the device can have higher re...

Page 37: ...r Function Host Name It is to set current host device name It max supports 32 digit character Ethernet Card Please select the Ethernet port It is for the wire LAN by default Please note for the W seri...

Page 38: ...DHCP mode to the static mode you need to reset the IP parameters Besides IP submask gateway and DHCP are read only when the PPPoE dial is OK Mac Address It is to display hose Mac address IP Version I...

Page 39: ...ess from the label of the speed dome Step 3 Go to the Run interface and then input the following commands arp s IP Address MAC ping l 480 t IP Address Such as arp s 192 168 0 125 11 40 8c 18 10 11 pin...

Page 40: ...annel 1 subtype 1 You need to input the following four items manually Username password IP and port The IP is device IP and the port default value is 554 You can leave it in blank if it is the default...

Page 41: ...gure 4 26 The DDNS is to set to connect the various servers so that you can access the system via the server Please go to the corresponding service website to apply a domain name and then access the s...

Page 42: ...r IP DDNS server IP address Server Port DDNS server port Domain Name Your self defined domain name User The user name you input to log in the server Password The password you input to log in the serve...

Page 43: ...40 You can add IP address or IP address section If you do not check the box here it means there is on access limit Figure 4 27 4 3 6 SMTP e mail The SMTP interface is shown as in Figure 4 28...

Page 44: ...if necessary Anonymity For the server supports the anonymity function You can auto login anonymously You do not need to input the user name password and the sender information User Name The user name...

Page 45: ...test email to check the connection is OK or not Please check the box to enable this function and then set the corresponding interval System can send out the email regularly as you set here Email test...

Page 46: ...the communication between the network management work station software and the proxy of the managed device Please install the software such as MG MibBrowser 8 0c software or establish the SNMP servic...

Page 47: ...ation access control and the management relationship between one proxy and one group of the managers Please make sure the device and the proxy are the same The read community will read all the objects...

Page 48: ...The Bonjour interface is shown as below See Figure 4 31 Bonjour is based on the multicast DNS service from the Apple The Bonjour device can automatically broadcast its service information and listen...

Page 49: ...elow See Figure 4 33 Qos Quality of Service is network security mechanism It is a technology to fix the network delay and jam problem and etc For the network service the quality of service includes th...

Page 50: ...63 The router or the switcher can provide different service for various data packets Command The value ranges from 0 to 63 The router or the switcher can provide different service for various data pac...

Page 51: ...48 Figure 4 34 Figure 4 35...

Page 52: ...ction zone setup Working Period Motion detection function becomes activated in the specified periods See Figure 4 35 There are six periods in one day Please draw a circle to enable corresponding perio...

Page 53: ...time after alarm ended The value ranges from 10s to 300s Send Email If you enabled this function System can send out email to alert you when alarm occurs and ends PTZ Here you can set PTZ movement whe...

Page 54: ...day Please draw a circle to enable corresponding period Select date If you do not select current setup applies to today only You can select all week column to apply to the whole week Click OK button s...

Page 55: ...rs PTZ Here you can set PTZ movement when alarm occurs Such as go to preset x when there is an alarm The event type includes preset tour and pattern Capture You need to input capture channel number so...

Page 56: ...rface here is for reference only The alarm output number may vary due to different series products Alarm Delay System can delay the alarm output for specified time after alarm ended The value ranges f...

Page 57: ...then trigger Please note the interface here is for reference only The alarm output number may vary due to different series products Trigger When the alarm output channel is open the output port can i...

Page 58: ...55 Figure 4 41 Figure 4 42...

Page 59: ...56 Figure 4 43 Figure 4 44...

Page 60: ...e only See Figure 4 45 You need to check the box to enable this function Record Delay System can delay the record for specified time after alarm ended The value ranges from 10s to 300s Relay Out The c...

Page 61: ...from the color bar Green color stands for the general record snapshot Yellow color stands for the motion detect record snapshot Red color stands for the alarm record snapshot Figure 4 46 4 5 2 Destin...

Page 62: ...t Type It includes general motion detect and alarm Local It saved in the SD card FTP It saved in the FTP server The local interface is shown as in Figure 4 48 Here you can view local SD card or disk i...

Page 63: ...on When network disconnect occurred or there is malfunction Emergency storage can save the record snapshot picture to the local SD card Figure 4 49 4 5 3 Record control The record control interface is...

Page 64: ...ecording or overwrite the previous files when HDD is full Stop Current working HDD is overwriting or current HDD is full it will stop record Overwrite Current working HDD is full it will overwrite the...

Page 65: ...ge from the dropdown list Please note the device needs to reboot to get the modification activated 4 6 1 2 Date and time The date and time interface is shown as in Figure 4 52 Figure 4 52 Please refer...

Page 66: ...count Note For the character in the following user name or the user group name system max supports 6 digits The space in the front or at the end of the string is null The valid string includes charact...

Page 67: ...lt is for system interior use only and can not be deleted When there is no login user hidden user default automatically login You can set some rights such as monitor for this user so that you can view...

Page 68: ...the user password You need to input the old password and then input the new password twice to confirm the new setup Please click the OK button to save Please note the password ranges from 1 digit to...

Page 69: ...s corresponding rights See Figure 4 58 Please input the group name and then check the box to select the corresponding rights It includes shutdown reboot device live view record control PTZ control and...

Page 70: ...wo interfaces 4 6 3 1 Network PTZ The network PTZ interface is shown as in Figure 4 59 Figure 4 59 Please refer to the following sheet for detailed information Parameter Function Protocol Select the c...

Page 71: ...ult value is 1 Baud Rate Set the baud rate you can control the speed dome via the RS485 Default setup is 9600 Data Bit Default setup is 8 Stop bit Default setup is 1 Parity Set the parity you can cont...

Page 72: ...69 Figure 4 61 4 6 5 Import Export The interface is shown as in Figure 4 62 Figure 4 62 Please refer to the following sheet for detailed information...

Page 73: ...re 4 63 Here you can select auto reboot and auto delete old files interval from the dropdown list If you want to use the auto delete old files function you need to set the file period Figure 4 63 4 6...

Page 74: ...rmation Information Information 4 7 1 Version The version interface is shown as in Figure 4 65 Here you can view system hardware features software version release date and etc Please note the followin...

Page 75: ...ta operation event operation record operation and user management log clear Start time Set the start time of the requested log End time Set the end time of the requested log Search You can select log...

Page 76: ...Parameter Function Clear You can click this button to delete all displayed log files Please note system does not support clear by type Backup You can click this button to backup log files to current...

Page 77: ...ction System alarms when motion detection alarm occurs Disk full System alarms when disk is full HDD malfunction System generates an alarm when HDD is malfunction Camera masking System alarms when cam...

Page 78: ...only Slight difference may be found in user interface All the designs and software here are subject to change without prior written notice All trademarks and registered trademarks are the properties...

Reviews: