27
Figure 4-16
Please refer to the following sheet for detailed informaiton.
Parameter
Function
Object
type
supported
You can select an object type here. The default setup is unknown.
Activate alarm
position
Here you can set the alarm activation position of the target frame.
There are five options: Centre/Left centre/Right centre/Top centre/Bottom centre.
Alarm
activation
number
(Person)
Here you can set the alarm activation amount. System will not generate an alarm if
the person amount is below the threshed you set here.
Min last time
Here is to set the min time between the target in the zone and an alarm activation
occurrence.
Report interval
It is to set alarm period. System just alarms once if the value is 0 here.
Target
size
filter
Click button
,
you can set the target filter model in this scene. Click the
button
,
you can remove selected target filter model.
4.2.3.5
Abandoned Object Detection
The abandoned object detection interface is shown as in Figure 4-17.