34
34
34
34
3.2.3. Sensor
User can install multiple sensors on the system to get the pre & post alarm recording and
intensive recording function as well.
ON/OFF
Turn on or turn off the sensor
CAM
Select the associated camera
OUT
Select the associated alarm output
Caution
Relay contact can stand up to 24V/1A. In case that it is connected to the external
circuit which is over 24V/1A, it can cause a problem on the system.
INTENSIVE RECODING
When alarm is triggered, system instantly assigns “remained fps” to alarm-triggered channel and
increases recording speed during the selected dwell time, and also will trigger alarm signal via
the selected sensor-out channel. The recording speed of all other channel will remain
unchanged.
PRESET
User can select the camera to move to preset position, once the sensor is triggered. (User should
setup preset position in PTZ menu 4.2.6 in advance)
DWELL (Post Alarm)
Set the recording period from the start of sensor input activation. During this period, the
corresponding camera image will record according to the frame and alarm (relay) output set. The
recording stops and alarm output is turned off when the setting period is elapsed.
Summary of Contents for DLW5400