System setting
MAIN MENU
SYSTEM SETTING
CAMERA SETTING
FUNCTION SETTING
WINDOW BLANKING
EXIT
S/N:
4JKAA7824000058
CONF:
SITE ID
001
COMM SPEED 4800BPS
PROTOCOL
VIDO B02
BACK
EXIT
4JKAA7824000058
COMM SETTING
SYSTEM SETTING
EDIT DOME LABEL
INITIAL INFO
DISPLAY SETUP
MOTION
CLEAR
PASSWORD SETTING
CLOCK SETTING
COMM SETTING
BACK
EXIT
1. The system enters into the main menu by calling 95 preset or by calling 9 preset
twice within 3 second.
2.
SYSTEM SETTING
, and pressing
OPEN
to enter into the next menu.
3.
COMM SETTING
, and pressing
OPEN
to enter into Dome parameter setup menu.
: Show Series NO. of the dome ex-work.
: Using to edit, the series NO. of the dome is the same as S/N
series Numer.
: Setting up the ID Number of the dome, address scope (001-255).
: Baud rate setup. The user can choose 4 kinds of Baud
rate (2400 BPS, 4800 BPS, 9600 BPS, 19200 BPS).
: set protocol, the user can choose 16 kinds of protocol:
PELCO, FACTORY, DYNACOLOR, ISD, HUNDA, VIDO B02, LILIN,
KALATEL, DIAMOND, SAMSUNG, PANASONIC, SANTACHI, VICON,
MOLYNX, VCL , SAE.
S/N
CONF
SITE ID
COMM SPEED
PROTOCOL
Operate joystick
move the cursor to
Operate joystick
move the cursor to
and
and
5. 9 COMM Setting
1. below operation can not be continue when above
two series Number are not the same.
2. The setting is effective while restart the dome
after finishing dome parameter setting
18
NOTICE