Page 42 of 65
Example of Printout from the Memory:
AIS-Auto # 1 Time/date: 11:55:47 / 16-12-2020
Message ID: 1 MMSI: 219015521
Position: 57d12.3688 N 9d41.0159 E Pos. accuracy: 1 Navigational status: 0
COG: NA SOG: 0.1 Knots ROT: NA HDT: NA Time stamp: 49
AIS1 RF: 161,974.7 kHz Fwd.: 11.7 Watt Rev.: 0.6 Watt VSWR: 1.63
AIS-Auto # 1 Time/date: 11:56:39 / 16-12-2020
Message ID: 11 MMSI: 219015521
Position: 57d12.3679 N 9d41.0167 E Electronic position fixing device: 15
Date: 16-12-2020 Time: 10:56:42
AIS2 RF: 162,024.6 kHz Fwd.: 11.7 Watt Rev.: 0.6 Watt VSWR: 1.63
AIS-Auto # 1 Time/date: 11:56:57 / 16-12-2020
Message ID: 1 MMSI: 219015521
Position: 57d12.3675 N 9d41.0163 E Pos. accuracy: 1 Navigational status: 0
COG: NA SOG: 0.0 Knots ROT: NA HDT: NA Time stamp: 00
AIS2 RF: 162,024.8 kHz Fwd.: 11.7 Watt Rev.: 0.6 Watt VSWR: 1.63
AIS-Auto # 1 Time/date: 11:57:08 / 16-12-2020
Message ID: 5 MMSI: 219015521
C.SIGN: XPE3261 IMO: 219015521 Name: DANPHONE@@@@@@@@@@@@
Type of ship: 30 Dimension of ship: A: 5 m B: 65 m C: 4 m D: 6 m
Electronic position fixing device: 15
Draught of ship: 8.0 m Destination: PANDRUP@@@@@@@@@@@@@
ETA: MMDD 12-01 HHMM 05:05
AIS1 RF: 161,975.2 kHz Fwd.: 11.8 Watt Rev.: 0.6 Watt VSWR: 1.63
AIS-Auto # 1 Time/date: 11:57:09 / 16-12-2020
Message ID: 8 MMSI: 219015521
AI: 10 ENI: 12301552 Length: 70.0 m Beam: 10.0 m
Type: 1000 H.Cargo: 5 Draught: 8.00 m Loaded: 0 Quality: 1 0 1
AIS1 RF: 161,975.0 kHz Fwd.: 11.7 Watt Rev.: 0.6 Watt VSWR: 1.63
AIS-Auto # 1 Time/date: 11:58:38 / 16-12-2020
Simulate ships: Received ok
AIS-Auto # 1 Time/date: 11:58:50 / 16-12-2020
Message ID: 12 MMSI: 219015521
Dest. MMSI: 999999999
TEST
AIS1 RF: 161,979.2 kHz Fwd.: 11.8 Watt Rev.: 0.6 Watt VSWR: 1.63
Receive AIS loop
In the Receive AIS loop mode the test box will receive and display the MMSI number and
message ID continuously from all AIS transponders within reach
– one at a time. The result is
kept in the display until the next is received. Results are displayed only, not stored in the
memory.
In this mode you also have a choice between AIS1 and AIS2.
Use setup 1, 2 or 5 from “Setup for AIS tests”.
Summary of Contents for Futronic MKII
Page 58: ...Page 58 of 65 Example of Test Report based on the default HTML design ...
Page 63: ...Page 63 of 65 ...
Page 64: ...Page 64 of 65 ...
Page 65: ......