D4-9 / D4-9X Four-Post Lifts
17
P/N 5900251 — Rev. A1— August 2021
Planning for Electrical Work
You will need to have a licensed, certified Electrician available at some point during the installation.
⚠
DANGER
All wiring
must
be performed by a licensed, certified Electrician in accordance with
local and national electrical codes.
Notify your Electrician in advance so that they come with a Power Disconnect Switch and a Thermal
Disconnect Switch. If you ordered a 220 VAC Power Unit, they will also need to bring appropriate
components.
Your Electrician needs to:
•
Install a Power Disconnect Switch
. Ensures you can quickly and completely interrupt
electrical power to the Lift in the event of an electrical circuit fault, emergency situation, or when
equipment is undergoing service or maintenance. Put it within sight and reach of the Lift operator.
•
Install a Thermal Disconnect Switch
. Ensures the equipment shuts down in the event of an
overload or an overheated motor.
•
Connect an electric power source to the Power Unit for 220 VAC Power Units
. If
you are using a 220 VAC Power Unit—instead of the standard 110 VAC Power Unit—your
Electrician will need to bring and install appropriate components. Refer to
Important
:
The standard 110 VAC Power Units come with a power cord and appropriate plug.
Just plug it in to a 110 VAC outlet.
Unloading and Unpacking
Once the components are unloaded, they are your responsibility to move around. As the Lift includes a
number of heavy pieces, the closer you unload them to the installation location, the better off you are.
⚠
CAUTION
Some Lift components are very heavy
; if handled incorrectly, they can
damage materials like tile, sandstone, and brick. Try to handle the Lift components
twice: once when delivered and once when moved into position. You must have a
Forklift or Shop Crane to move them into position. Use care when moving them.
⚠
WARNING
The Lift is delivered with stabilizing structures on each end. Be
very
careful when
removing these stabilizing structures; the Posts and Runways can shift or even fall.
If they fall on a person, they could cause serious injury.
Important Note
:
Before removing the Powerside Runway (the Runway with the Hydraulic Cylinder and the Lifting
Cables under it), remove the four Runway Sheaves on one end of the Powerside Runway and the two
Runway Sheaves on the other end.
Pay attention to the order in which the Runway Sheaves come off; later in the
installation you will need to put them back into place in the reverse order from how
you took them off
.
Summary of Contents for D4-9
Page 10: ...D4 9 D4 9X Four Post Lifts 10 P N 5900251 Rev A1 August 2021 Specifications Side View Top View...
Page 60: ...D4 9 D4 9X Four Post Lifts 60 P N 5900251 Rev A1 August 2021...
Page 71: ...D4 9 D4 9X Four Post Lifts 71 P N 5900251 Rev A1 August 2021 Labels...
Page 72: ...D4 9 D4 9X Four Post Lifts 72 P N 5900251 Rev A1 August 2021...
Page 73: ...D4 9 D4 9X Four Post Lifts 73 P N 5900251 Rev A1 August 2021...
Page 74: ...D4 9 D4 9X Four Post Lifts 74 P N 5900251 Rev A1 August 2021...
Page 75: ...D4 9 D4 9X Four Post Lifts 75 P N 5900251 Rev A1 August 2021 Parts Drawings...
Page 76: ...D4 9 D4 9X Four Post Lifts 76 P N 5900251 Rev A1 August 2021...
Page 77: ...D4 9 D4 9X Four Post Lifts 77 P N 5900251 Rev A1 August 2021...
Page 78: ...D4 9 D4 9X Four Post Lifts 78 P N 5900251 Rev A1 August 2021...
Page 79: ...D4 9 D4 9X Four Post Lifts 79 P N 5900251 Rev A1 August 2021...
Page 80: ...D4 9 D4 9X Four Post Lifts 80 P N 5900251 Rev A1 August 2021...
Page 81: ...D4 9 D4 9X Four Post Lifts 81 P N 5900251 Rev A1 August 2021 Maintenance Log...
Page 82: ...D4 9 D4 9X Four Post Lifts 82 P N 5900251 Rev A1 August 2021 Maintenance Log...
Page 83: ...D4 9 D4 9X Four Post Lifts 83 P N 5900251 Rev A1 August 2021 Maintenance Log...
Page 85: ...1645 Lemonwood Drive Santa Paula CA 93060 USA 2021 BendPak Inc All rights reserved dannmar com...