System components 

The  CU  6005/6010  Central  Unit  supports  all 
available units in the DCS 6000 series: 

Central equipment etc. 

EX 6010 

Extension Unit 

PS 6000 

Power Supply 

AO 6004 

Audio Output box 

AO 6008 

Audio Output box 

RP 6004 

Repeater for four chains 

JB 6002 

Junction Box with 2 outputs 

JB 6004 

Junction Box with 4 outputs 

Interpreter equipment 

IS 6132P 

Interpreter Set  

LS 6132P 

Interpreter Loudspeaker 

Voting equipment 

DV 6501F 

Voting Unit 

 
 
 
 
 
 

Conference equipment and channel 
selectors
 

CS 6032FV/H 

Channel Selector (flush mounted) 

CM/DM 6010P  Conference Unit (portable) 
DM 6060P 

Conference  Unit  (portable)  with 
one built-in channel selector 

CM/DM 6070P  Conference  Unit  (portable)  with 

two built-in channel selectors  

CM/DM 6090P  Conference  Unit  (portable)  with 

two built-in channel selectors and 
XLR microphone connector 

CM/DM 6060F   Conference Unit (flush mounted) 

with 

one 

built-in 

channel 

selectors 

CM/DM 6510F  Conference Unit (flush mounted) 

with  Chip-card  and  3  voting 
buttons 

CM/DM 6560F  Conference Unit (flush mounted) 

with 

one 

built-in 

channel 

selector,  Chip-card  and  3  voting 
buttons 

MU 6040C/D  

Microphone  Unit  for  use  with 
customised  front  plate  with 
Loudspeaker,  Microphone  and 
Buttons.  Available  in  Delegate 
(D) and Chairman (C) version 

MU 6042D  

Dual Microphone Unit for use 
with FD/FC front plate with 
Loudspeaker, Microphone and 
two delegate Buttons

 

AM 6040 

Ambient Noise Microphone 

 

 

Summary of Contents for DCS 600

Page 1: ...DCS 6000 User Manual Danish Interpretation Systems DIS Digital Conference System AO 6008 Audio Output Unit with firmware 5 3 5 or later...

Page 2: ...pretation Systems User Manual Copyright 2007 DIS AO6008 REV M DOC 16 01 2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from th...

Page 3: ...6000 system 5 Features 5 System components 6 Central equipment etc 6 Interpreter equipment 6 Voting equipment 6 Conference equipment and channel selectors 6 Operating instructions 7 AO 6008 Audio Outp...

Page 4: ...ions You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment Installation precautions Do not install the unit in a...

Page 5: ...reened CAT5 or CAT5e cabling FTP or STP ensuring a very cost effective installation and easy set up of portable systems Firmware in Delegate units Interpreter Units Central Units etc upgradeable throu...

Page 6: ...portable DM 6060P Conference Unit portable with one built in channel selector CM DM 6070P Conference Unit portable with two built in channel selectors CM DM 6090P Conference Unit portable with two bu...

Page 7: ...e 8 decoded channels are available on 8 analogue outputs XLR connectors A number of AO 6008 can be combined to decode more channels Up to 20 pieces AO 6008 can be connected and configured in one syste...

Page 8: ...placed on the left hand side of the display Each button is associated with a line pointing towards a text line in the display This indicates that pushing the button selects the functionality Enter bu...

Page 9: ...lying transformer balanced audio signal from each of the 8 channels The outputs can be used for tape recording purpose i e or for connecting a digital infrared transmitter like DT6008 DT 6032 or analo...

Page 10: ...ed so the user can check the volume level while adjusting it The last item on the volume menu list is All by selecting this item the user can change the volume setting for all the outputs simultaneous...

Page 11: ...user presses ENTER the settings of the unit are replaced by the settings stored in the clipboard The settings stored in the clipboard are Channel settings for all 8 outputs Volume settings for all 8 o...

Page 12: ...e lock status is being saved in the CU 6010 and retransmitted to the unit after power up Normal operation Normal Operation Display In normal operation the user must be able to check the language setti...

Page 13: ...th in one chain is 200 m without repeater This includes interconnection cables between the units The max usable cable length depends on the units connected and length of feeding cables etc Maximum cab...

Page 14: ...recorders for recording the interpreted channels or to IT6008 Infrared Transmitter s for transmitting the interpreted channels wireless Using AO 6008 with IT 6108 IR Transmitter When using the AO 6008...

Page 15: ...the DT 60xx Infrared Transmitter the audio output level on the AO 6008 has to be set to match the sensitivity on the transmitter The correct level to be set on each connected channel on the AO 6008 is...

Page 16: ...follows Pair 1 Pin 1 2 Pair 2 Pin 3 6 Pair 3 Pin 4 5 Pair 4 Pin 7 8 The phase of the pairs must be correct and the wiring spec as stated in CAT5 EIA 568 B have to be followed Note CAT6 cables can norm...

Page 17: ...er manual Connectors DCS LAN network 2 pieces RJ45 Analogue outputs connectors 8 XLR3 male connectors Remote Control commands in out By using SW 6000 the user can control the AO 6008 through the CU 60...

Page 18: ...Danish Interpretation Systems User Manual Manual 01 18 04440 18...

Reviews: