Danish Interpretation Systems DCS 600 User Manual Download Page 4

Danish Interpretation Systems 

 

User Manual 

 

Manual 01 18 04440

 

4

Important 

Compliancy 

The equipment has been tested and found to comply 
with the limits of the following standards for digital 
devices: 

 

EN55103-1 (Emission) 

 

EN55103-2 (Immunity)  

 

FCC rules part 15, class A (Emission) 

This device complies with part 15 of the FCC rules. 
Operation is subject to the following conditions: (1) 
This  device  may  not  cause  harmful  interference, 
and  (2)  this  device  must  accept  any  interference 
received,  including  interference  that  may  cause 
undesired operation. 

These  limits  are  designed  to  provide  reasonable 
protection  against  harmful  interference  when  the 
equipment  is  operated  in  a  commercial  or  light 
industrial  environment.  The  equipment  generates, 
uses, and can radiate radio frequency energy and if 
not  installed  and  used  in  accordance  with  the  user 
manual  it  may  cause  harmful  interference  to  radio 
communications. 

You 

are 

cautioned 

that 

any 

changes 

or 

modifications not expressly approved in this manual 
could void your authority to operate this equipment. 

Installation precautions 

Do  not  install  the  unit  in  a  location  near  heat 
sources such as radiators or air ducts, or in a place 

exposed  to  direct  sunlight,  excessive  dust  or 
humidity, mechanical vibration or shock. 

To  avoid  moisture  condensations  do  not  install  the 
unit where the temperature may rise rapidly. 

Cleaning 

To  keep  the  cabinet  in  its  original  condition, 
periodically  clean  it  with  a  soft  cloth.  Stubborn 
stains  may  be  removed  with  a  cloth  lightly 
dampened with a mild detergent solution. Never use 
organic  solvents  such  as  thinners  or  abrasive 
cleaners since these will damage the cabinet. 

Repacking 

Save  the  original  shipping  cardboard  box  and 
packing  material;  they  will  become  handy  if  you 
ever have to ship the unit. For maximum protection, 
re-pack  the  unit  as  originally  packed  from  the 
factory. 

Warranty 

The  individual  units  in  the  DCS  6000  system  are 
minimum  covered  by  12  months  warranty  against 
defects 

in 

materials 

or 

workmanship..

 

Summary of Contents for DCS 600

Page 1: ...DCS 6000 User Manual Danish Interpretation Systems DIS Digital Conference System AO 6008 Audio Output Unit with firmware 5 3 5 or later...

Page 2: ...pretation Systems User Manual Copyright 2007 DIS AO6008 REV M DOC 16 01 2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from th...

Page 3: ...6000 system 5 Features 5 System components 6 Central equipment etc 6 Interpreter equipment 6 Voting equipment 6 Conference equipment and channel selectors 6 Operating instructions 7 AO 6008 Audio Outp...

Page 4: ...ions You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment Installation precautions Do not install the unit in a...

Page 5: ...reened CAT5 or CAT5e cabling FTP or STP ensuring a very cost effective installation and easy set up of portable systems Firmware in Delegate units Interpreter Units Central Units etc upgradeable throu...

Page 6: ...portable DM 6060P Conference Unit portable with one built in channel selector CM DM 6070P Conference Unit portable with two built in channel selectors CM DM 6090P Conference Unit portable with two bu...

Page 7: ...e 8 decoded channels are available on 8 analogue outputs XLR connectors A number of AO 6008 can be combined to decode more channels Up to 20 pieces AO 6008 can be connected and configured in one syste...

Page 8: ...placed on the left hand side of the display Each button is associated with a line pointing towards a text line in the display This indicates that pushing the button selects the functionality Enter bu...

Page 9: ...lying transformer balanced audio signal from each of the 8 channels The outputs can be used for tape recording purpose i e or for connecting a digital infrared transmitter like DT6008 DT 6032 or analo...

Page 10: ...ed so the user can check the volume level while adjusting it The last item on the volume menu list is All by selecting this item the user can change the volume setting for all the outputs simultaneous...

Page 11: ...user presses ENTER the settings of the unit are replaced by the settings stored in the clipboard The settings stored in the clipboard are Channel settings for all 8 outputs Volume settings for all 8 o...

Page 12: ...e lock status is being saved in the CU 6010 and retransmitted to the unit after power up Normal operation Normal Operation Display In normal operation the user must be able to check the language setti...

Page 13: ...th in one chain is 200 m without repeater This includes interconnection cables between the units The max usable cable length depends on the units connected and length of feeding cables etc Maximum cab...

Page 14: ...recorders for recording the interpreted channels or to IT6008 Infrared Transmitter s for transmitting the interpreted channels wireless Using AO 6008 with IT 6108 IR Transmitter When using the AO 6008...

Page 15: ...the DT 60xx Infrared Transmitter the audio output level on the AO 6008 has to be set to match the sensitivity on the transmitter The correct level to be set on each connected channel on the AO 6008 is...

Page 16: ...follows Pair 1 Pin 1 2 Pair 2 Pin 3 6 Pair 3 Pin 4 5 Pair 4 Pin 7 8 The phase of the pairs must be correct and the wiring spec as stated in CAT5 EIA 568 B have to be followed Note CAT6 cables can norm...

Page 17: ...er manual Connectors DCS LAN network 2 pieces RJ45 Analogue outputs connectors 8 XLR3 male connectors Remote Control commands in out By using SW 6000 the user can control the AO 6008 through the CU 60...

Page 18: ...Danish Interpretation Systems User Manual Manual 01 18 04440 18...

Reviews: