Direct screw install
WS103 device direct screw install
1
2
kwa1459380563336
1. WS103
2. M4 screws with internal-6kt / DIN 912 - ISO 4762, length = at least 25 mm
The module can be installed directly with two M4 cylinder screws with indoor 6kt DIN 912 / ISO 4762,
length = at least 25 mm. Tighten the mounting screws of the module with a torque of M = 0.9 N•m to 1.1
N•m.
•
DIN 6797 - external tooth lock washer is recommended.
•
For the distances between the holes, see
WS103 dimensions
on page 57.
•
The module can be mounted in any position, in the case of outdoor installation, place it in a way that
does not allow water or liquid on to the connectors, see
Ingress protection rating
on page 58
Ingress protection rating
W
Warning
International Protection Marking of IP 67 rating is not ensured if all connectors are not plugged in. Before
exposing the device to dust and water, plug in all connectors. Do not immerse the device in water or
other liquids. Make sure that WS devices are stored and transported at a temperature between -40 °C and
+85 °C or -40 °F and +185 °F respectively.
User Manual
WS103 Remote Solution
Appendix B – Mounting
58 |
©
Danfoss | July 2016
AN00000339en-US0101