Instructions for installation and use
VXe Solo HT
© Danfoss | Produced by Danfoss Redan A/S | 2023.01 | 9
AQ440953137531en-010102
1
Plate heat exchanger HE, with insulation
5 Strainer
6 Non-return valve
7
Ball valve
8A Circulation pump, HE
8B Circulation pump, cylinder
11 Safety valve HE, 3 bar ½”
13 Thermometer
14 Pocket for pressure gauge
15 Manometer
16 Expansion vessel 12 l
17 Air valve
23 Sensor pocket ½” for heat meter
24 Fitting piece for heat meter 3/4” x 110 mm
25 Controller Danfoss ECL310/A337
29 Danfoss actuator AMV
30 Danfoss flow controller with integrated control valve AVQM
---------------------------------------------------------------------------------------
Option:
54 Safety thermostat, Jumo AT
Accessories available as extra equipment (mounting on site)
Thermostatic valve RAVK/VMA for DHW
Code No. 144B2021
NOTE!
Optionally, the VXe Solo HWS HT can be supplied with the control
valve AHQM instead of the AVQM.
Primary
HE r
etur
n
HE supply
DH supply
DH r
etur
n
Secondary
DHW
4. MAIN COMPONENTS / CONNECTION- VXE SOLO HWS HT ECL 310/A337
C
ylinder supply
C
ylinder r
etur
n
7
25
16
17
29
23
13
6
11
1
30
8A
8B
14
23
15
5
54
24
5
5
5