N O T I C E
After connection, tighten all 4 screws on the terminal box cover. The tightening torque is 3 Nm (26.6 in-lb).
5.5 CleanConnect® Connection
shows the connection power plug for VLT® OneGearDrive® Hygienic V210 with thermistors.
e30bb868.12
V1
W1
U1
U
V
W
2
3
D
C
A
B
1
4
T1
T2
Illustration 10: CleanConnect
®
OneGearDrive Connection Diagram
Table 11: CleanConnect
®
Connections
Description
Inverter output
Pin
Typical cross-section
Maximum cross-section
Motor winding
U
1
1.5 mm
2
/AWG 16
2.5 mm
2
/AWG 14
V
3
W
4
Protective earth
PE
2
1.5 mm
2
/AWG 16
2.5 mm
2
/AWG 14
Temperature protection
(1)
KTY 84-130
T1
A
0.75 mm
2
/AWG 20
1.5 mm
2
/AWG 16
T2
B
1
When connected to VLT® AutomationDrive FC 302 and VLT® Decentral Drive FCD 302, use analog input terminal 54, KTY sensor 1. For information
about parameter setting and programming, refer to the corresponding Operating Guides.
Table 12: Connections T1 and T2
T1
KTY 84-130
VLT® AutomationDrive FC 302
(1)
VLT® AutomationDrive FC 302
(1)
T2
KTY sensor 1
Analog input 54
1
Only if connected.
5.6 Overload Protection
).
For thermal protection, the built-in KTY sensor can be connected. Alternatively, the ETR function of the VLT
®
AutomationDrive
FC 302 or VLT® Decentral Drive FCD 302 can be used.
AQ347551551757en-000101 / 130R0239
20 | Danfoss A/S © 2020.12
Electrical Installation
VLT® OneGearDrive®
Operating Guide