1
Rotor width, minimum 5.5 mm (0.2 in)
2
Air gap, maximum 0.45 mm (0.02 in)
3
Fastening screws
4
Armature plate
5
Magnet
6
Springs
7
Hub for rotor
8
Rotor
9
Friction plate
10
Hollow screws
11
Brake cover, plastic disks, and nuts
Illustration 11: Brake and Rotor
Procedure
Disconnect the brake from the rectifier (see
).
Open the brake completely by turning the brake cover nuts [11] counterclockwise.
Loosen the fastening screws [3] completely by turning them counterclockwise.
Remove the installed brake and rotor from the hub of the rotor [7].
Assemble the new brake and rotor on the hub of the rotor [7].
Tighten the fastening screws [3].
Check the brake cover seal and exchange it if any damage is detected.
Close the brake cover and tighten the covering nuts [11] with tightening torque 2.3 Nm (20.36 in-lb). Always replace the
plastic disks with new ones.
Connect the brake to the rectifier (see
AQ347551551757en-000101 / 130R0239 | 25
Danfoss A/S © 2020.12
Maintenance, Decommissioning,
and Disposal
VLT® OneGearDrive®
Operating Guide
Summary of Contents for VLT OneGearDrive
Page 1: ...Operating Guide VLT OneGearDrive drives danfoss com...
Page 2: ......