6.14.9.2 Configuring the Update Time
Procedure
1. Open the
HW Config
tool.
2. Select the path for the PROFINET
®
I/O system.
3. Select the menu [Edit
→
Object properties].
4. In the next window, open the
Update Time
tab, highlight the I/O device and click on the
Edit
button.
5. In the next window (
Edit Update Time/Mode
), select the
Update Time
and click on
OK
.
e
3
0
b
g
3
6
6
.1
0
Illustration 95: Set Update Time
NOTICE
-
The system cycle clocks of the PLC program must be the same as the PROFINET
®
send clock, otherwise data may be
lost and performance reduced.
6.14.10 Accessing Inputs and Outputs
Context:
SIMOTION SCOUT
®
provides access to the device inputs and outputs of the SIMOTION device via the process image of cyclic tasks using
I/O variables.
Commissioning
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 127
Danfoss A/S © 2019.10