N O T I C E
See the back of the terminal cover for outlines of control terminals and switches.
N O T I C E
Do not operate switches with power on the drive.
N O T I C E
Set
parameter 6-19 Terminal 53 Mode
according to Switch 4 position.
Table 5: Settings for S200 Switches 1–4
Switch 1
Off=PNP terminals 29
(1)
On=NPN terminals 29
Switch 2
Off=PNP terminal 18, 19, 27, and 33
(1)
On=NPN terminal 18, 19, 27, and 33
Switch 3
No function
Switch 4
Off=Terminal 53 0–10 V
(1)
On=Terminal 53 0/4-20 mA
1
This is the default setting.
e3
0b
a4
74
.1
0
ON
OFF
1
2
4
3
PN
P/
N
PN
PN
P/
N
PN
U
/I
Illustration 4: S200 Switches 1–4
The following illustration shows all control terminals of the drive. Applying start (terminal 18) and an analog reference (terminal 53
or 60) make the drive run.
AQ348848915086en-000101 / 130R0943 | 13
Danfoss A/S © 2020.09
Installation
VLT® Micro Drive FC 51
Operating Guide