N710
N800
Normal load
NO
NO
(Normal overload=110% current during 60 s)
Typical shaft output at 550 V [kW]
560
670
Typical shaft output at 575 V [hp]
750
950
Typical shaft output at 690 V [kW]
710
800
Enclosure size
E2h/E4h
E2h/E4h
Output current (3-phase)
Continuous (at 550 V) [A]
763
889
Intermittent (60 s overload) (at 550 V) [A]
839
978
Continuous (at 575/690 V) [A]
730
850
Intermittent (60 s overload) (at 575/690 V) [A]
803
935
Continuous kVA (at 550 V) [kVA]
727
847
Continuous kVA (at 575 V) [kVA]
727
847
Continuous kVA (at 690 V) [kVA]
872
1016
Maximum input current
Continuous (at 550 V) [A]
735
857
Continuous (at 575 V) [A]
704
819
Continuous (at 690 V) [A]
704
819
Maximum number and size of cables per phase (E2h)
- Mains and motor without brake [mm
2
(AWG)]
1)
6x240 (6x500 mcm)
6x240 (6x500 mcm)
- Mains and motor with brake [mm
2
(AWG)]
1)
5x240 (5x500 mcm)
5x240 (5x500 mcm)
- Brake or regeneration [mm
2
(AWG)]
1)
2x185 (2x350 mcm)
2x185 (2x350 mcm)
Maximum number and size of cables per phase (E4h)
- Mains and motor [mm
2
(AWG)]
1)
6x240 (6x500 mcm)
6x240 (6x500 mcm)
- Brake [mm
2
(AWG)]
1)
2x185 (2x350 mcm)
2x185 (2x350 mcm)
- Load share or regeneration [mm
2
(AWG)]
1)
4x185 (4x350 mcm)
4x185 (4x350 mcm)
Maximum external mains fuses [A]
2)
1200
1200
Estimated power loss at 600 V [W]
3)4)
10346
12723
Estimated power loss at 690 V [W]
3)4)
10066
12321
Efficiency
4)
0.98
0.98
Output frequency [Hz]
0–590
0–590
Heat sink overtemperature trip [
°
C (
°
F)]
110 (230)
110 (230)
Control card overtemperature trip [
°
C (
°
F)]
80 (176)
80 (176)
Power card overtemperature trip [
°
C (
°
F)]
85 (185)
85 (185)
Fan power card overtemperature trip [
°
C (
°
F)]
85 (185)
85 (185)
Active in-rush card overtemperature trip [
°
C (
°
F)]
85 (185)
85 (185)
Table 9.4 Technical Specifications, Mains Supply 3x525–690 V AC
1) American Wire Gauge.
2) For fuse ratings, see chapter 9.7 Fuses.
3) Typical power loss is at normal conditions and expected to be within
±
15% (tolerance relates to variety in voltage and cable conditions.) These
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to www.danfoss.com/vltenergyefficiency. Options and
customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add only 4 W.
4) Measured using 5 m shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficiency
class, see chapter 9.4 Ambient Conditions. For part load losses, see www.danfoss.com/vltenergyefficiency.
Specifications
Operating Guide
MG16O102
Danfoss A/S © 01/2017 All rights reserved.
77