6.
Press [
▲
] and [
▼
] to select correct parameter
setting. Or, to move to digits within a number,
press keys. cursor indicates digit selected to
change. [
▲
] increases the value, [
▼
] decreases the
value.
7.
Press [Cancel] to disregard change, or press [OK]
to accept change and enter new setting.
6.1.8 Changing a Text Value
If the selected parameter is a text value, change the text
value with the [
▲
]/[
▼
] keys.
[
▲
] increases the value, and [
▼
] decreases the value. Place
the cursor on the value to be saved and press [OK].
130BP068.10
740RPM
0 -01 Language
[0] English
10.64 A
1 [1]
0-0*
Basic Settings
Figure 6.20 Display Example
6.1.9 Changing a Group of Numeric Data
Values
If the selected parameter represents a numeric data value,
change the selected data value with the [
◄
] and [
►
] keys
as well as the up/down [
▲
] [
▼
] keys. Press [
◄
] and [
►
] to
move the cursor horizontally.
130BP069.10
1- 6*
113 RPM 1.78 A 1(1)
Load depen. setting
1 - 60 Low speed load
compensation
1
0
0%
Figure 6.21 Display Example
Press [
▲
] and [
▼
] to change the data value. [
▲
] increases
the data value, and [
▼
] decreases the data value. Place the
cursor on the value to be saved and press [OK].
130BP070.10
1 - 60 Low speed load
compensation
1 0%
Load depen. setting
1- 6*
729RPM
6.21A 1(1)
6
Figure 6.22 Display Example
6.1.10 Changing of Data Value, Step by
Step
Certain parameters can be changed step-by-step or by an
infinite number of variables. This applies to
parameter 1-20 Motor Power [kW]
and
parameter 1-23 Motor Frequency
.
The parameters are changed both as a group of numeric
data values, and as numeric data values using an infinite
number of variables.
6.1.11 Readout and Programming of
Indexed Parameters
Parameters are indexed when placed in a rolling stack.
Parameter 15-30 Alarm Log: Error Code
to
parameter 15-32 Alarm Log: Time
contain a fault log which
can be read out. Select a parameter, press [OK], and use
[
▲
] and [
▼
] to scroll through the value log.
Use
parameter 3-10 Preset Reference
as another example:
Select the parameter, press [OK], and use [
▲
] and [
▼
] to
scroll through the indexed values. To change the
parameter value, select the indexed value and press [OK].
Change the value by [
▲
] and [
▼
]. Press [OK] to accept the
new setting. Press [Cancel] to abort. Press [Back] to leave
the parameter.
6.2 Parameter Menu Structure
How to Program
VLT
®
HVAC Drive FC 102
108
Danfoss A/S © 08/2014 All rights reserved.
MG11F522
6
6
Summary of Contents for VLT HVAC Drive FC 102
Page 2: ......