4.2 Digital and Analog I/Os
4.2.1 MCO 352 I/O
X57/1 Input MCO352 Over/Under
Option:
Function:
Determines whether the winder will operate for over or under winding. The motor direction will need
to change depending on whether the material is wrapping over or under the winder core. The di-
rection selected will also affect the jog directions.
NB!
This input is scanned only when tension is OFF.
X57/2 Input MCO352 Winder Jog Reverse
Option:
Function:
Jogs winder in the reverse winding direction at the speed programmed in par. 19-07 (Winder Jog
Speed).
NB!
This input is scanned only when tension is OFF.
X57/3 Input MCO352 Winder Jog Forward
Option:
Function:
Jogs winder in Forward winding direction at the speed programmed in par. 19-07 (Winder Jog
Speed).
NB!
This input is scanned only when tension is OFF.
X57/4 Input MCO352 Partial Roll Select
Option:
Function:
Selects new setting in parameter 19-04 as the preset starting diameter when the Diameter Reset
(Input 8) is energized, rather than using one of the two preset core diameters. If the initial diameter
is to be measured by an analog signal, this input must be held ON along with the correct setting in
parameters 19-13 to 19-16.
NB!
This input is scanned only when tension is OFF.
VLT
®