AHF 005/010

Specifications

Dimensions/weight

The AHF-modules are available in six frame sizes (size B to G).
For dimensions see the drawings on the following pages

AHF 010, 380 – 415 V AC, 50Hz

AHF 010, 440 – 480 V AC, 60Hz

I

AHF,N

Frame

size

Weight

I

AHF,N

Frame

size

Weight

10 A

B

19 Kg (42 lbs)

19 A

B

21 Kg (46 lbs)

19 A

B

23 Kg (51 lbs)

26 A

B

22 Kg (48 lbs)

26 A

B

34 Kg (75 lbs)

35 A

B

31 Kg (68 lbs)

35 A

B

40 Kg (88 lbs)

43 A

C

38 Kg (84 lbs)

43 A

C

45 Kg (99 lbs)

72 A

D

56 Kg (123 lbs)

72 A

D

61 Kg (134 lbs)

101 A

D

69 Kg (152 lbs)

101 A

D

75 Kg (165 lbs)

144 A

D

97 Kg (214 lbs)

144 A

D

95 Kg (209 lbs)

180 A

E

103 Kg (227 lbs)

180 A

E

107 Kg (236 lbs)

217 A

E

112 Kg (247 lbs)

217 A

E

119 Kg (262 lbs)

289 A

F

135 Kg (298 lbs)

289 A

F

145 Kg (320 lbs)

324 A

F

180 Kg (397 lbs)

AHF 005, 380 – 415 V AC, 50Hz

AHF 005, 440 – 480 V AC, 60Hz

I

AHF,N

Frame

size

Weight

I

AHF,N

Frame

size

Weight

10 A

B

21Kg (46 lbs)

19 A

B

25 Kg (55 lbs)

19 A

B

29 Kg (64 lbs)

26 A

C

28 Kg (62 lbs)

26 A

C

40 Kg (88 lbs)

35 A

C

39 Kg (86 lbs)

35 A

C

50 Kg (110 lbs)

43 A

D

50 Kg (110 lbs)

43 A

D

52 Kg (115 lbs)

72 A

D

74 Kg (163 lbs)

72 A

D

89 Kg (196 lbs)

101 A

E

82 Kg (181 lbs)

101 A

E

150 Kg (331 lbs)

144 A

E

130 Kg (287 lbs)

144 A

E

169 Kg (373 lbs)

180 A

F

144 Kg (317 lbs)

180 A

F

178 Kg (392 lbs)

217 A

F

162 Kg (357 lbs)

217 A

F

225 Kg (496 lbs)

289 A

G

201 Kg (443 lbs)

289 A

G

273 Kg (602 lbs)

324 A

G

255 Kg (562 lbs)

MG.80.B2.02 - VLT is a registered Danfoss trademark

7

Summary of Contents for VLT AHF 005

Page 1: ...Drives Solutions www danfoss com drives InstructionManual Harmonic Filter AHF 005 010...

Page 2: ...ns weight 7 Dimension diagrams 8 Installation 10 Mechanical installation 10 Ventilation 10 Power wiring 10 Over temperature contactor 11 Power wiring size copper 12 Operation on different mains type 1...

Page 3: ...rrectly and used in accordance with their purpose Avoid filter module damage 1 The filter modules are to be used only with Danfoss frequency converters The usage with other electrical loads is not per...

Page 4: ...ortion to 10 AHF 005 reduces the total harmonic current distortion to 5 Current rating from 10A 324A For higher power modules can be paralleled One filter module can be used for several frequency conv...

Page 5: ...8150 289 A 132 160 175G6610 175G6632 5200 5250 6175 6225 8200 8250 324 A 175G6611 175G6633 Higher ratings can be achieved by paralleling the filter units 360 A 200 Two 180 A units 5300 6275 8300 434...

Page 6: ...rying from the input current ratings of VLT 5000 VLT 6000 and VLT 8000 series as stated in the respective operating instructions as these numbers are based on different operating conditions Calculatio...

Page 7: ...al load If these conditions are not or only partially fulfilled a significant reduction of the harmonic components can still be achieved but the rated THiD values may not be achieved Environmental dat...

Page 8: ...03 Kg 227 lbs 180 A E 107 Kg 236 lbs 217 A E 112 Kg 247 lbs 217 A E 119 Kg 262 lbs 289 A F 135 Kg 298 lbs 289 A F 145 Kg 320 lbs 324 A F 180 Kg 397 lbs AHF 005 380 415 V AC 50Hz AHF 005 440 480 V AC 6...

Page 9: ...AHF 005 010 Dimension diagrams Frame size B Frame size C Frame size D MG 80 B2 02 VLT is a registered Danfoss trademark 8...

Page 10: ...AHF 005 010 Specifications Frame size E Frame size F Frame size G MG 80 B2 02 VLT is a registered Danfoss trademark 9...

Page 11: ...536 W 43 A 463 W 72 A 898 W 72 A 776 W 101 A 1260 W 101 A 1089 W 144 A 1796 W 144 A 1553 W 180 A 2245 W 180 A 1941 W 217 A 2706 W 217 A 2340 W 289 A 3604 W 289 A 3116 W 324 A 3493 W NB If other heat s...

Page 12: ...lter becomes the sum of the individual current ratings Use cables complying with local regulations Over temperature contactor The Danfoss harmonic filter AHF 005 and AHF 010 is equipped with a galvani...

Page 13: ...This type of termination imposes no specifications of the minimum and maximum cable size suitable for connection Power terminal details regarding the bus bars can be found in the figures below Frame...

Page 14: ...m or thick grounding tapes Use copper or tinned copper screened wires only as steel screened wires are not suitable for high frequency applications Connect the screen with metal clamps or metal glands...

Page 15: ...t correct a non intended operation of controller and or filter module is possible First powering up 1 Switch on mains supply The filter module is ready for operation at once 2 Check the readiness of t...

Page 16: ...In particular during transport and handling no components are allowed to be bend and or isolating distances may not be altered The units are equipped with electrostatic sensitive devices which may be...

Page 17: ...ecause of possibly charged capacitors During operation all covers and doors must be closed 7 Maintenance and service The manufacturer s documentation must be observed This safety information must be k...

Page 18: ......

Reviews: