VLT® 2800 Series
■
Connection examples
■
Start/stop
Start/stop using terminal 18 and coasting
stop using terminal 27.
Par. 302
Digital input
=
Start
[7]
Par. 304
Digital input
=
Coasting stop inverted
[2]
For Precise start/stop the following settings are made:
Par. 302
Digital input
=
Precise start/stop
[27]
Par. 304
Digital input
=
Coasting stop inverted
[2]
■
Pulse start/stop
Pulse start using terminal 18 and pulse stop
using terminal 19. In addition, the jog frequency
is activated via terminal 29.
Par. 302
Digital input
=
Pulse start
[8]
Par. 303
Digital input
=
Stop inverted
[6]
Par. 304
Digital input
=
Coasting stop inverted
[2]
Par. 305
Digital input
=
Jog
[13]
■
Speed up/slow down
Speed up/slow down using terminals 29/33.
Par. 302
Digital input
=
Start
[7]
Par. 303
Digital input
=
Freeze reference
[14]
Par. 305
Digital input
=
Speed up
[16]
Par. 307
Digital input
=
Slow down
[17]
■
Potentiometer reference
Voltage reference via a potentiometer.
Par. 308
Analog input
=
Reference
[1]
Par. 309
Terminal 53, min. scaling
= 0 Volt
Par. 310
Terminal 53, max. scaling
= 10 Volt
■
Connection of a 2-wire transmitter
Connection of a 2-wire transmitter as feedback
to terminal 60.
Par. 314
Analog input
=
Feedback
[2]
Par. 315
Terminal 60, min. scaling
= 4 mA
MG.28.A8.22 - VLT is a registered Danfoss trademark