118
Resistor (9)
k
Ω
12V cut-out
V
12V cut-in
V
12V max.
Voltage
24V cut-out
V
24Vcut-in
V
24V max
Voltage
Resistore (9)
k
Ω
12V stacco
V
12V attacco
V
Max tensione
a 12V
24V stacco
V
24V attacco
V
Max tensione
A 24V
0
9.6
10.9
17.0
21.3
22.7
31.5
1.6
9.7
11.0
17.0
21.5
22.7
31.5
2.4
9.9
11.1
17.0
21.8
22.9
31.5
3.6
10.0
11.3
17.0
22.0
23.2
31.5
4.7
10.1
11.4
17.0
22.3
23.4
31.5
6.2
10.2
11.5
17.0
22.5
23.7
31.5
8.2
10.4
11.7
17.0
22.8
23.9
31.5
11
10.5
11.8
17.0
23.0
24.2
31.5
14
10.6
11.9
17.0
23.3
24.5
31.5
18
10.8
12.0
17.0
23.6
24.7
31.5
24
10.9
12.2
17.0
23.8
25.0
31.5
33
11.0
12.3
17.0
241
25.2
31.5
47
11.1
12.4
17.0
24.3
25.5
31.5
82
11.3
12.5
17.0
24.6
25.7
31.5
220
9.6
10.9
26.0
31.5
Fig.13
Wire dimensions
Dimensioni cavi
(Fig.11)
Cross section
mm²
Max length*
m 12V
operation
Max length* m
24V operation
Sezione mm²
Max.
lunghezza* m
funzionament
o a 12V
Max.
lunghezza* m
funzionamento
a 12V
2.5
4
6
10
2.5
4
6
10
5
8
12
20
Lenght between battery and electronic unit
Lunghezza tra la batteria e l’unità elettronica
Standard battery protection setting
Impostazioni standard protezione batteria
(Fig.12)
12V cut-
out
V
12V cut-in
V
24V cut-out
V
24V cut-in
V
12V stacco
V
12V attacco
V
24V stacco
V
24V attacco
V
10.4
11.7
22.8
24.2
Compressor speed
Velocità compressore
(Fig.14)
Resistor (8)
Ω
Motor speed
rpm
Contr.Circ.
Current mA
Resistore (8)
Ω
Velocità
motore
giri/min
Corrente
circuito
controllo mA
0
277
692
1523
2000
2500
3000
3500
5
4
3
2
Fig.10
Optional battery protection setting
Impostazioni opzionali protezione batteria
Summary of Contents for Vitrifrigo BD35
Page 113: ...113 ...
Page 114: ...114 ...
Page 115: ...115 ...
Page 116: ...116 ...
Page 117: ...117 ...