background image

11

GB - User Instructions

To convert to Thermostat mode 

 

Press & hold 

 and 

 together until 

display changes to colon blinking & 
default temperature (8°C).

Press 

 or 

 to alter temperature  

as required.

 

  

(If not already in Thermostat Mode, press 
& hold 

 and 

 together until display 

changes to colon blinking & 8°C)

Press 

DAY

 (display will show a suitcase 

and :00) 

Press 

+ and - 

to enter number of days 

of holiday (max.99)
 
Use 

 and 

 buttons to alter the 

constant temperature, if required.  

When selected number of days have 
elapsed, the unit will return to normal, 
controlling according to your set 
programmes. 

NOTE

: Press 

 and 

 buttons together 

to exit holiday mode if necessary

To programme Holiday Mode

(whilst in Thermostat Mode)  

The TP7000 can be converted to control at a constant user 
selected temperature, instead of following the set programme. 

!

NOTE:

 unit will remain in thermostat mode until the 

 and 

 buttons are pressed together again. 

The TP7000 can control at a constant low temperature while 
you are away on holiday, returning to your programmed settings 
after a specifi ed number of days (maximum 99 days). 

Summary of Contents for TP7000M

Page 1: ...sungen Inbetriebnahme Instruktion Instrucciones de instalaci n Instrucciones del usuario Instruktions vejledning Brugervejleding 7 day programmable room thermostat Installatie handleiding Instructiese...

Page 2: ...Instrucciones de instalaci n 33 36 Instrucciones del usuario 37 42 Instruktions vejledning 43 46 Brugervejleding 47 52 Installatie handleiding 53 56 Instructiesevoor Gebruik 57 62 63 66 67 72 Instruk...

Page 3: ...of output relay N A 1 x SPDT Type 1B Switch rating of relay contact voltage and current N A 3 1 A 230 volts Transmitter frequency RF only 433 92 MHz N A Transmitter range RF only 30 meters max N A Ra...

Page 4: ...the back of the unit From the top left hand corner of the wallplate there must be clearances of at least 140mm to the right 15mm to the left 30mm above and 100mm below in order to mount the plug in m...

Page 5: ...tain a set temperature achieving a constant ambient environment for the user L N M models only Setting Optimum Start Control 4 C 3 C 2 C 1 C A B C 120 min 90 min 60 min 30 min Event 1 time 0 D Set Sw2...

Page 6: ...for 3 seconds until green light ashes once 4 RX2 if applicable Stat 1 perform steps 1 3 Stat 2 wait 5 mins perform steps1 2 and then press PROG and CH2 on RX2 RX3 if applicable Stat 1 perform steps 1...

Page 7: ...s and temperatures which often suit most people If you want you can change any of these settings by following the instructions on pages 9 10 First follow the steps on page 8 to set your display prefer...

Page 8: ...10 min increments This display will ONLY appear if the OSC function has been enabled by your installer Use the or buttons to select the OSC period The choices are 0 30 30 mins 1 00 1 hr 1 30 and 2 00...

Page 9: ...NEXT to advance to next Event iv Repeat steps i ii iii above for Events 2 3 4 5 6 Programming in 7 day mode separate programmes for each day of the week 1 Before you change the preset programmes Your...

Page 10: ...ntil colon ashes in display Press PROG until Event 1 ashes then press DAY until display shows Day 1 5 Follow steps b c on page 9 10 to programme times temperatures for weekdays Press DAY to programme...

Page 11: ...ture if required When selected number of days have elapsed the unit will return to normal controlling according to your set programmes NOTE Press and buttons together to exit holiday mode if necessary...

Page 12: ...a hours and press 4 times to remove override To alter main LCD display to show either time or actual room temperature press NEXT COPY together Batteries will last in excess of two years Low battery in...

Page 13: ...Part No 37045 Issue 1 04 05 www danfoss com BusinessAreas Heating...