5.  Referring to the wiring diagrams on page 6-12, connect the unit as 

shown.

6.  The unit is supplied ready for use in systems having PUMPED 

primaries. 

 

Should the unit be required for use in a system having GRAVITY 
primaries, fi t the small plastic shorting link (which can be found 
taped below the left hand fi xing screw hole of the wallplate) over 
the two pins on the rear of the plug-in module. These pins can 
be found in the recess near to the bottom edge of the plug-in 
module. 

7.  Ensure all dust and debris are cleared from the area.

8.  Locate the module on the latches at the bottom of the wallplate 

and hinge upwards to fully engage the unit connectors into the 
wallplate. Tighten the two fi xing screws to secure the unit to the 
wallplate.

9.  Before setting the programme, check the unit and circuit. 

  Switch ON the mains supply and press both 

WATER

 and 

HEATING

 rocker switches to the

 CONSTANT

 position - both red 

LED’s should now be illuminated. Adjust any remote thermostat 
to check the services operate correctly.

Leave at least 
25mm below 
product

Rear entry 
cable access

Cable aperture 
knockouts

Wall or 
plasterbox 
fi xing

Terminal 
block

Outline of 
programmer

Leave suffi

  cient space 

for screwdriver access

C/L

Summary of Contents for SET3M

Page 1: ...SET3M Electro Mechanical 24 Hour Programmer for Heating and Hot Water Installation Guide Danfoss Heating MAKING MODERN LIVING POSSIBLE...

Page 2: ...n 0845 121 7400 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material All trademarks in this material are property of the respective companies Dan...

Page 3: ...ity DHW Pumped HTG 7 3 3 Typical Fully Pumped System with Spring Return Zone Valve in Heating 8 3 4 Typical Gravity DHW Pumped HTG with Spring Return Zone Valve in DHW 9 3 5 Typical Fully Pumped Syste...

Page 4: ...trician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations 1 Fix the wallplate to the wall or ush mounted box as required The connection...

Page 5: ...st and debris are cleared from the area 8 Locate the module on the latches at the bottom of the wallplate and hinge upwards to fully engage the unit connectors into the wallplate Tighten the two xing...

Page 6: ...of systems are shown on the following pages Note Whilst every attempt has been made to ensure the accuracy of this information it is recommended that the speci c information relating to the ancillary...

Page 7: ...r Danfoss Randall products suitable for use with above circuit RMT room thermostat 3 2 Typical Gravity DHW Pumped HTG Boiler Pump N N L 1 2 3 4 5 6 Terminals Mains Supply 3 amp fuse Room Stat N L D H...

Page 8: ...cts suitable for use with above circuit AT cylinder thermostat RMT room thermostat HP22 or HP28 motorised zone valve with spring return actuator and SPST auxiliary switch Boiler and Pump S R Z V in HT...

Page 9: ...all products suitable for use with above circuit AT cylinder thermostat RMT room thermostat HP28C motorised zone valve with spring return actuator and SPDT auxiliary switch S R Z V in DHW N L 1 2 3 4...

Page 10: ...products suitable for use with above circuit AT cylinder thermostat RMT room thermostat HS3 3 port mid position valve with spring return actuator Boiler and Pump 3 port mid position valve N N L 1 2 3...

Page 11: ...suitable for use with above circuit AT cylinder thermostat RMT room thermostat 2 x HP22 or HP28 motorised zone valve with spring return actuator and SPST auxiliary switch S R Z V in DHW N L 1 2 3 4 5...

Page 12: ...ach Service Other Danfoss Randall products suitable for use with above circuit AT cylinder thermostat RMT room thermostat F M Z V in DHW Boiler and Pump N N L 1 2 3 4 5 6 Terminals Mains Supply 3 amp...

Page 13: ...o determine how the SET3M programmer s GRAVITY or PUMPED link should be set If there is any doubt about the way in which the existing programmer is connected please contact our Technical Services Depa...

Page 14: ...methyst 7 10 2 3 1 5 4 7 6 8 Horstmann 424 GEM 2 3 1 1 0 4 5 6 7 8 9 Terminals 5 8 10 are linked Horstmann Leucite 423 424 2 1 3 5 4 6 7 8 Terminals 5 7 are linked Honeywell ST669 N L 6 8 7 3 5 4 Land...

Page 15: ...Centroller 90 1 2 5 4 3 6 Smith Ind Centroller 1000 N L 3 1 4 2 Pumped Gravity link is set to Pumped Switchmaster 800 805 N L 3 4 1 2 Switchmaster 900 9000 N L 3 4 1 2 Pumped Gravity link is set to P...

Page 16: ...Part No 3547v01 03 11 Danfoss Randall Ltd Ampthill Road Bedford MK42 9ER Tel 0845 1217 400 Fax 0845 1217 515 Email danfossrandall danfoss com Website www danfoss randall co uk...

Reviews: