Compensated high flow PVBZ with POC and manifold interface
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independence on the load pressure of other functions used
simultaneously.
The integrated LS
A/B
relief valve is used to limit the maximum work port build-up on the A/B-ports
individually.
The bleed-off will prevent pressure build-up on the work ports in neutral.
Features
•
Integrated LS shuttle network
•
Integrated high flow compensator with bleed-off
•
Integrated POC
•
T0 facility
•
Integrated adjustable LS
A/B
pressure relief valves
•
Optional thermo relief valve
Schematic
1
0
2
1
0
2
A
B
A
B
Technical specification for A/B-port
Max. continuous pressure
Max. intermittent pressure
Max. rated flow
350 bar [5076 psi]
420 bar [6090 psi]
125 l/min [33 US gal/min]
Technical specification
Parameter
Minimum
Recommended range
Maximum
Fluid temperature
-30°C [-22°F]
30 to 60°C [86 to 140°F]
90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS]
12 to 75 mm
2
/s [65 to 347 SUS]
460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Technical Information
PVG-EX 32 Proportional Valve Group
PVB Basic Modules
70 |
©
Danfoss | June 2019
BC290860493426en-000103