![Danfoss PVG-EX 32 Technical Information Download Page 42](http://html.mh-extra.com/html/danfoss/pvg-ex-32/pvg-ex-32_technical-information_507231042.webp)
Uncompensated PVB with load drop check valve
The uncompensated PVB is intended for controlling a work function where the function behavior in
terms of flow and pressures allows dependency on the load pressure of other functions used
simultaneously. The integrated load drop check valve prevents flow back from work ports influencing
other functions.
The Uncompensated PVB with load drop check valve features:
•
Integrated LS shuttle network
•
Load drop check valve
•
Optional shock/anti-cavitation valve facility (PVLP)
•
Optional LS
A/B
shuttle valve facility for float spool use
•
Optional T0 facility
Schematic
A
B
1
0
2
Technical specification for A/B-port
Max. continuous pressure
Max. intermittent pressure
Max. rated flow
350 bar [5076 psi]
420 bar [6090 psi]
125 l/min [33 US gal/min]
Technical specification
Parameter
Minimum
Recommended range
Maximum
Fluid temperature
-30°C [-22°F]
30 to 60°C [86 to 140°F]
90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS]
12 to 75 mm
2
/s [65 to 347 SUS]
460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Technical Information
PVG-EX 32 Proportional Valve Group
PVB Basic Modules
42 |
©
Danfoss | June 2019
BC290860493426en-000103