![Danfoss PVG-EX 32 Technical Information Download Page 49](http://html.mh-extra.com/html/danfoss/pvg-ex-32/pvg-ex-32_technical-information_507231049.webp)
Dampened Compensated PVB
The compensated PVB is intended for controlling a work function where the function behavior in terms
of flow and pressures requires independence on the load pressure of other functions used
simultaneously. The dampening of the compensator reaction will slow down the system thereby
removing instability.
The dampened compensated PVB features:
•
Integrated LS shuttle network
•
Integrated compensator
•
Optional shock/anti-cavitation valve facility (PVLP)
Compensated PVB schematic
A
B
1
0
2
T P LX
Pp
Technical specification for A/B-port
Max. continuous pressure
Max. intermittent pressure
Max. rated flow
*
350 bar [5076 psi]
420 bar [6090 psi]
125 l/min [33 US gal/min]
*
With turbo function spool @ max rated flow of 130 l/min is possible
Technical specification
Parameter
Minimum
Recommended range
Maximum
Fluid temperature
-30°C [-22°F]
30 to 60°C [86 to 140°F]
90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS]
12 to 75 mm
2
/s [65 to 347 SUS]
460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Technical Information
PVG-EX 32 Proportional Valve Group
PVB Basic Modules
©
Danfoss | June 2019
BC290860493426en-000103 | 49