background image

Technical Information

Proportional Valve Group

PVG-EX 32

www.danfoss.com

Summary of Contents for PVG-EX 32

Page 1: ...Technical Information Proportional Valve Group PVG EX 32 www danfoss com ...

Page 2: ... Rev June 2019 New EU Declaration of Conformity 0103 May 2019 Updated EU Declaration of Conformity and minor changes 0102 May 2019 First edition 0101 Technical Information PVG EX 32 Proportional Valve Group 2 Danfoss June 2019 BC290860493426en 000103 ...

Page 3: ... Dampened compensated PVB with LS A B 52 Compensated PVB with LS A B 55 Compensated high flow PVB 59 Compensated high flow PVB with LS A B 62 Compensated PVBZ with POC 66 Compensated high flow PVBZ with POC 68 Compensated high flow PVBZ with POC and manifold interface 70 PVB Basic Modules Accessories PVLP Shock and Anti Cavitation Valve 72 PVLA Suction Valve 74 PVBS Main Spools PVBS fluid flow cha...

Page 4: ...tion with B float 111 Pressure Flow Control Spools Throttled Open Neutral Position 111 Pressure Flow Control Spools Open Closed Neutral Position 112 Pressure Flow Control Spools Open Closed A and Closed B Position 112 PVBS for PVBZ Main Spools Part Numbers PVBZ Flow Control Spools Closed Neutral Position 113 PVBZ Flow Control Spools Closed Neutral Position with A float 114 PVBZ Flow Control Spools...

Page 5: ...cation The machine builder system integrator alone is responsible for making the final selection of the products and assuring that all performance safety and warning requirements of the application are met The process of choosing the control system and safety levels is governed by Machinery Directive 2006 42 EC and harmonized standard EN 13849 Safety related requirements for control systems W Warn...

Page 6: ...XXX 6 1 4 5 3 2 Nameplate legend Number Description 1 PVG Valve Group code number 2 Code number production date and serial number Example 42 12 C xxxxxx Week 42 Year 2012 Day C Wednesday A Monday Serial number 3 CE Conformity marking 4 EU marking per 80079 Standard part 5 Ambient temperature range 6 EU marking per 2014 34 EU Directive part Technical Information PVG EX 32 Proportional Valve Group P...

Page 7: ...lass T5 T4 Ex marking EU Directive part Description EU Marking CE conformity marking CE Explosion protection marking Equipment Group I II Equipment Category M2 2G EPL Equipment category EPL Equipment category Definition Level of protection Typical zone of application IEC EU EPL Group Category Group Mines Very high N A Ma I M1 I High Mb M2 Gas atmosphere Very high 0 Ga II 1G II High 1 Gb 2G Enhance...

Page 8: ...f this function Oil flow to one function is independent of the load pressure of other functions Good regulation characteristics Energy saving Up to 12 basic modules per valve group Several types of connection threads Low weight Compact design and installation Inlets The inlets include Built in pressure relief valve Pressure gauge connection Versions for different pump types Open Center systems wit...

Page 9: ...with lever Manual with friction detent Hydraulic Electro hydraulic ON OFF control Ratiometric proportional CANbus proportional PWM proportional Technical Information PVG EX 32 Proportional Valve Group General information Danfoss June 2019 BC290860493426en 000103 9 ...

Page 10: ...ompensator 5 Orifice closed center 15 LS connection port A 6 Pressure adjustment spool 16 LS connection port B 7 Plug closed center 17 Suction valve PVLA 8 LS connection 18 Load drop check valve 9 LS signal 19 Pilot oil supply for PVE 10 Shuttle valve 20 Maximum oil flow adjustment screws for A B ports Technical Information PVG EX 32 Proportional Valve Group General information 10 Danfoss June 201...

Page 11: ... PVP Inlet Modules on page 12 PVB Basic Modules on page 38 PVBS Main Spools on page 75 PVSKM Full Flow Cut Off Modules on page 126 PVAS Stay Bolts on page 131 Technical Information PVG EX 32 Proportional Valve Group General information Danfoss June 2019 BC290860493426en 000103 11 ...

Page 12: ...nds of any hydraulic system Open Center PVP on page 13 for fixed displacement pumps Open Center PVP with PPRV on page 16 for fixed displacement pumps Open center PVP with HPCO and PVE PPRV on page 19 for fixed displacement pumps Closed Center PVP on page 22 for variable displacement pumps Closed Center PVP with PPRV on page 24 for variable displacement pumps Closed center PVPV with PPRV on page 27...

Page 13: ...M actuation Open center PVP schematic LS T P M Technical specification for PVP Max P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 l min 37 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 39 SUS...

Page 14: ...ter PVP Part number P port T port LS M port LS1 T0 port Mounting 157B5000 G1 2 G3 4 G1 4 M8 157B5100 G3 4 157B5200 7 8 14 UNF 1 1 16 12 UNF 1 2 20 UNF 5 16 18 UNC 157B5300 1 1 16 UN 110088521 G1 2 G3 4 G1 4 G1 8 M8 11030545 G3 4 G3 4 G1 4 G1 4 G1 4 M8 11053974 G3 4 G3 4 G1 4 G1 4 G1 4 M8 11151852 1 1 16 12 UNF 1 1 16 12 UNF 9 16 18 UNF 9 16 18 UNF M8 157B5908 1 1 16 12 UNF 1 1 16 12 UNF 1 2 20 UNF...

Page 15: ... LS1 T0 port Mounting 157B5945 G1 2 G3 4 G1 4 G1 8 M8 157B59902 1 1 16 12 UNF 1 1 16 12 UNF M8 LS1 is an extra LS port 1 Dampened LS response 2 No relief valve Technical Information PVG EX 32 Proportional Valve Group PVP Inlet Modules Danfoss June 2019 BC290860493426en 000103 15 ...

Page 16: ...ssure port Pp All modules can be manually activated with the PVM actuation Open center PVP with PPRV schematic Pp LS T P M Technical specification for PVP Max P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 l min 37 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperat...

Page 17: ... by pass pressure drop characteristics l min US gal min 20 20 40 60 80 100 120 140 16 12 8 4 160 80 0 0 0 240 psi bar 4 8 12 16 20 24 28 32 36 0 Pilot pressure reduction valve characteristics l min US gal min 20 10 20 30 40 50 16 18 12 14 10 8 4 6 2 100 20 60 0 0 0 220 140 180 260 psi bar 6 12 2 4 8 10 0 Technical Information PVG EX 32 Proportional Valve Group PVP Inlet Modules Danfoss June 2019 B...

Page 18: ... G1 4 M8 11020964 PVE 1 1 16 12 UNF 1 1 16 12 UNF 1 2 20 UNF 1 2 20 UNF M8 110875901 PVH PVHC G3 4 G3 4 G1 4 G1 4 G1 4 M8 11090453 PVE JIS 3 4 JIS 3 4 JIS 1 4 JIS 1 4 JIS 1 4 JIS 1 4 M8 111194292 PVE G3 4 G3 4 G1 4 G1 4 G1 4 M8 11124966 PVH PVHC G3 4 G3 4 G1 4 G1 4 G1 4 M8 111309412 PVE 1 1 16 12 UNF 1 1 16 12 UNF 9 16 18 UNF 9 16 18 UNF 9 16 18 UNF 5 16 18 UNC 11196947 PVE G3 4 G3 4 G1 4 G1 4 G1 ...

Page 19: ...nd external T0 port Optional external pilot pressure port Pp Only applicable with PVST end plates with separate T port due to blocked T lines for HPCO functionality Open Center PVP with HPCO PVE PPRV schematic LS HPCO P M T0 Technical specification for PVP Max P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 ...

Page 20: ... by pass pressure drop characteristics l min US gal min 20 20 40 60 80 100 120 140 16 12 8 4 160 80 0 0 0 240 psi bar 4 8 12 16 20 24 28 32 36 0 Pilot pressure reduction valve characteristics l min US gal min 20 10 20 30 40 50 16 18 12 14 10 8 4 6 2 100 20 60 0 0 0 220 140 180 260 psi bar 6 12 2 4 8 10 0 Technical Information PVG EX 32 Proportional Valve Group PVP Inlet Modules 20 Danfoss June 201...

Page 21: ...4 G1 4 G1 4 M8 157B5340 1 1 16 12 UNF 1 1 16 12 UNF 1 2 20 UNF 1 2 20 UNF 1 2 20 UNF 1 2 20 UNF 5 16 18 UNC 157B5961 M27x2 M27x2 M14x1 5 M14x1 5 M14x1 5 M8 11101195 M22x1 5 M16x1 5 P2 M22x1 5 M12x1 5 M10x1 M16x1 5 M8 Technical Information PVG EX 32 Proportional Valve Group PVP Inlet Modules Danfoss June 2019 BC290860493426en 000103 21 ...

Page 22: ...schematic LS T P M Technical specification for PVP Max P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 l min 37 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 39 SUS 12 to 75 mm2 s 65 to 347 SU...

Page 23: ...1 4 G1 4 M8 157B5001 G1 2 G3 4 G1 4 G1 4 M8 157B5101 G3 4 G3 4 G1 4 G1 4 M8 157B5201 7 8 14 UNF 1 1 16 12 UNF 1 2 20 UNF 1 2 20 UNF 5 16 18 UNC 157B5301 1 1 16 12 UNF 1 1 16 12 UNF 1 2 20 UNF 1 2 20 UNF 5 16 18 UNC 15B5907 1 1 16 12 UNF 1 1 16 12 UNF 1 2 20 UNF 1 2 20 UNF M8 157B5922 JIS 1 2 JIS 3 4 JIS 1 4 JIS 1 4 M8 157B5927 JIS 3 4 JIS 3 4 JIS 1 4 JIS 1 4 M8 157B5946 G1 2 G3 4 G1 4 G1 8 G1 4 M8...

Page 24: ...external T0 port Closed center PVP with PPRV schematic Pp LS T P M Technical specification for PVP Max P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 l min 37 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid visc...

Page 25: ...T0 port Mounting 11051802 PVH PVHC 1 1 16 12 UNF 1 1 16 12 UNF 1 2 20 UNF 1 2 20 UNF 1 2 20 UNF 1 2 20 UNF 5 16 18 UNC 157B5011 PVE G1 2 G3 4 G1 4 G1 4 M8 157B5111 PVE G3 4 G3 4 G1 4 G1 4 M8 157B5131 PVE G3 4 G3 4 G1 4 G1 4 G1 4 G1 4 M8 157B5181 PVE G3 4 G3 4 G1 4 G1 4 G1 4 M8 157B5191 PVH PVHC G3 4 G3 4 G1 4 G1 4 G1 4 M8 157B5211 PVE 7 8 14 UNF 1 1 16 12 UNF 1 2 20 UNF 1 2 20 UNF 5 16 18 UNC 157B...

Page 26: ...dditional threaded ports for P2 T2 and T02 PVPV Schematic T LS P M Technical specification for PVP Max P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 l min 37 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid visc...

Page 27: ...P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 l min 37 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 39 SUS 12 to 75 mm2 s 65 to 347 SUS 460 mm2 s 2128 SUS Fluid cleanliness 23 19 16 accordi...

Page 28: ...8 G1 G1 G1 4 G1 4 G1 4 M8 157B5941 G1 G1 G1 4 G1 4 G1 4 M8 Yes 157B59483 G1 G1 G1 4 G1 4 G1 4 M8 Yes 157B59734 G1 G1 G1 4 G1 4 G1 4 M8 Yes 157B5978 M27x2 0 M33x2 0 M14x1 5 M14x1 5 G1 4 M8 11008856 PVH PVHC G1 G1 G1 4 G1 4 G1 4 M8 Yes 11051803 1 5 16 12 1 5 16 12 9 16 18 9 16 18 G1 4 5 16 18 Yes 157B5916 1 5 16 12 1 5 16 12 9 16 18 9 16 18 G1 4 5 16 18 157B5963 1 1 16 12 1 1 16 12 7 16 20 M18x1 5 9...

Page 29: ...ulic schematic T LS P M Technical specification for PVP Max P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 l min 37 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 39 SUS 12 to 75 mm2 s 65 to 3...

Page 30: ...G1 4 M8 157B5940 G1 G1 G1 4 G1 4 G1 4 M8 Yes 11083156 PVH PVHC 1 1 16 12 UNF 1 1 16 12 UNF 9 16 18 UNF 9 16 18 UNF G1 4 5 16 18 UNC Yes 157B5912 1 5 16 12 UNF 1 5 16 12 UNF 9 16 18 UNF 9 16 18 UNF G1 4 5 16 18 UNC 157B5986 G1 G1 G1 4 G1 4 G1 4 M8 Yes All modules can be manually activated with the PVM actuation Technical Information PVG EX 32 Proportional Valve Group PVP Inlet Modules 30 Danfoss Ju...

Page 31: ...r Integrated LS pressure relief valve Threaded ports for P T LS and M measuring gauge Integrated pilot pressure reducing valve PPRV for PVE or PVH PVHC Optional LS boost functionality Hydraulic schematic LS T P M OC CC Technical specification for PVP Max P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 l min ...

Page 32: ... by pass pressure drop characteristics l min US gal min 20 20 40 60 80 100 120 140 16 12 8 4 160 80 0 0 0 240 psi bar 4 8 12 16 20 24 28 32 36 0 Pilot pressure reduction valve characteristics l min US gal min 20 10 20 30 40 50 16 18 12 14 10 8 4 6 2 100 20 60 0 0 0 220 140 180 260 psi bar 6 12 2 4 8 10 0 Technical Information PVG EX 32 Proportional Valve Group PVP Inlet Modules 32 Danfoss June 201...

Page 33: ...4 G3 4 G1 4 M8 11119095 PVE 1 1 16 12 UNF 1 1 16 12 UNF 1 2 20 UNF 1 2 20 UNF M8 11131344 PVH PVHC G3 4 G3 4 G1 4 M8 Yes 111686081 PVE G3 4 G3 4 G1 4 M8 Yes LS1 is an extra LS port 1 Dampened LS response All modules can be manually activated with the PVM actuation Technical Information PVG EX 32 Proportional Valve Group PVP Inlet Modules Danfoss June 2019 BC290860493426en 000103 33 ...

Page 34: ...s for P T Pilot pressure and T0 lines through module Hydraulic schematic T P Technical specification for PVP Max P port continuous Max P port intermittent Max T port static dynamic Max rated flow 350 5076 psi 400 bar 5800 psi 25 40 bar 365 580 psi 140 l min 37 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F ...

Page 35: ...lve External pilot pressure adapters PVPC with or without check valve for all Open Center PVP with PPRV PVPC without Check Valve on page 36 PVPC with Check Valve on page 37 Technical Information PVG EX 32 Proportional Valve Group PVP Inlet Module Accessories Danfoss June 2019 BC290860493426en 000103 35 ...

Page 36: ...roup with oil from a manually operated emergency pump without directing oil flow to the PPRV When the main pump is running in its normal operation mode the oil is directed through the PVPC adapter via the PPRV to the PVE electrical actuators When the main pump flow fails the external shuttle valve ensures that the oil flow from the manually operated emergency pump is used to pilot open the over ce...

Page 37: ...rom the pressure side of the cylinder is fed via the PVPC through the PPRV to act as the pilot supply for the PVE electrical actuators This means that it is possible to lower a load by means of the PVE electrical actuators without starting the pump The built in check valve prevents the oil from flowing via the pressure adjustment spool to tank With the pump functioning normally the external soleno...

Page 38: ... hydraulic system The generic PVB basic module platform includes the following main variants Uncompensated PVB on page 39 Uncompensated PVB with load drop check valve on page 42 Uncompensated PVBZ with POC on page 45 Compensated PVB on page 46 Dampened Compensated PVB on page 49 Dampened compensated PVB with LS A B on page 52 Compensated PVB with LS A B on page 55 Compensated high flow PVB on page...

Page 39: ...n With PVSI end plate With PVS end plate max 300 4351 psi Intermittent pressure at max 250 000 cycles of full PVG life time cycles with PVSI end plate The maximum intermittent pressure at max 250 000 cycles stresses the need to confirm application duty cycle before proceeding with specification For further information contact Danfoss Product Application Engineering Technical specification Paramete...

Page 40: ... min 70 75 80 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 20 18 16 14 12 10 8 6 4 2 0 85 90 95 100 22 23 24 25 26 Q 28 26 24 22 P P 200 160 120 80 40 0 280 240 320 400 360 0 psi bar 0 Q 105 110 115 120 27 28 29 30 31 PVLP PVLA Part numbers for uncompensated PVB Part number A B port PVLP PVLA LS A B shuttle T0 facility 157B6000 G1 2 157B6010 Yes 157B6030 Yes 11071832 Yes Yes Technical Inf...

Page 41: ...B continued Part number A B port PVLP PVLA LS A B shuttle T0 facility 157B6400 7 8 14 UNF 157B6410 Yes 157B6430 Yes Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules Danfoss June 2019 BC290860493426en 000103 41 ...

Page 42: ...cility PVLP Optional LSA B shuttle valve facility for float spool use Optional T0 facility Schematic A B 1 0 2 Technical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 125 l min 33 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F F...

Page 43: ...4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 20 18 16 14 12 10 8 6 4 2 0 85 90 95 100 22 23 24 25 26 Q 28 26 24 22 P P 200 160 120 80 40 0 280 240 320 400 360 0 psi bar 0 Q 105 110 115 120 27 28 29 30 31 PVLP PVLA Part numbers for Uncomp PVB with load drop check valve Part number A B port PVLP PVLA LS A B shuttle T0 facility 157B6100 G1 2 157B6500 7 8 14 UNF 157B6110 G1 2 Yes 157B6909 7 8 14 UN...

Page 44: ...PVLA LS A B shuttle T0 facility 157B6130 G1 2 Yes 157B6530 7 8 14 UNF Yes 157B6140 G1 2 Yes Yes 157B6904 7 8 14 UNF Yes Yes 157B6136 G1 2 Yes Yes 157B6536 7 8 14 UNF Yes Yes Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules 44 Danfoss June 2019 BC290860493426en 000103 ...

Page 45: ...intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 125 l min 33 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 39 SUS 12 to 75 mm2 s 65 to 347 SUS 460 mm2 s 2128 SUS Fluid cleanliness 23 19 16 according to ISO 4406 Operating temperature Ambient 30 to 60 C 22 to 14...

Page 46: ...nical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5067 psi 420 bar 6090 psi 125 l min 33 US gal min With turbo function spool max rated flow of 130 l min is possible Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 39 SUS 12 to 75 mm2 s 65 t...

Page 47: ...00 2000 1000 0 6000 0 0 Load Independent Fluid Flow Pressure Compensated PVB 10 20 30 40 50 60 70 80 90 100 l min US gal min 2 4 6 8 9 12 14 16 18 20 22 24 26 250 225 200 175 150 125 100 75 50 25 0 275 P 2500 2000 1500 1000 500 0 3500 3000 bar psi 110 28 AA B C D A E Q Q Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules Danfoss June 2019 BC290860493426en 000103 47 ...

Page 48: ...0 400 360 0 psi bar 0 Q 105 110 115 120 27 28 29 30 31 PVLP PVLA Part numbers for compensated PVB Part number A B port PVLP PVLA T0 157B6200 G1 2 157B6210 Yes 157B6230 Yes 157B6240 Yes Yes 157B6600 7 8 14 UNF 157B6922 Yes 157B6630 Yes 157B6906 Yes Yes 157B6850 M22x1 5 Yes Yes 157B6849 None Machined top prepared for mounting of a PVBD diverter Technical Information PVG EX 32 Proportional Valve Grou...

Page 49: ... schematic A B 1 0 2 T P LX Pp Technical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 125 l min 33 US gal min With turbo function spool max rated flow of 130 l min is possible Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity...

Page 50: ...00 2000 1000 0 6000 0 0 Load Independent Fluid Flow Pressure Compensated PVB 10 20 30 40 50 60 70 80 90 100 l min US gal min 2 4 6 8 9 12 14 16 18 20 22 24 26 250 225 200 175 150 125 100 75 50 25 0 275 P 2500 2000 1500 1000 500 0 3500 3000 bar psi 110 28 AA B C D A E Q Q Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules 50 Danfoss June 2019 BC290860493426en 000103 ...

Page 51: ...5 90 95 100 22 23 24 25 26 Q 28 26 24 22 P P 200 160 120 80 40 0 280 240 320 400 360 0 psi bar 0 Q 105 110 115 120 27 28 29 30 31 PVLP PVLA Part numbers for damp compensated PVB Part number A B port PVLP PVLA 157B6206 G1 2 157B6236 Yes 11036629 7 8 14 UNF 11036630 Yes Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules Danfoss June 2019 BC290860493426en 000103 51 ...

Page 52: ...ef valves External LSA B port connection Optional shock anti cavitation valve facility PVLP Dampened compensated PVB with LS A B schematic 1 0 2 A B B LSA LS T P LS Technical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 125 l min 33 US gal min With turbo function spool max rated flow of 130 l min is possible Parameter...

Page 53: ...dent Fluid Flow Pressure Compensated PVB 5 10 15 20 25 30 35 40 45 50 55 60 65 l min US gal min 70 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 0 25 50 75 100 125 150 175 200 225 250 275 300 0 500 1000 1500 2000 2500 3000 3500 4000 P AA B C D A P bar psi A 10 l min B 15 l min AA 5 min C 25 l min D 40 l min Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules Danfoss June 2019...

Page 54: ...5 120 27 28 29 30 31 PVLP PVLA PVB pressure compensated for LS A B characteristics l min US gal min P Q P bar psi 5 10 15 20 25 30 35 40 45 50 55 60 65 70 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 250 225 200 175 150 125 100 75 50 25 0 350 325 300 275 2500 2000 1500 1000 500 0 3500 3000 4000 5000 4500 0 Part number A B port LS port PVLP PVLA 157B6208 G1 2 G1 4 157B6238 Yes Technical Information...

Page 55: ... shock anti cavitation valve facility PVLP Optional T0 facility Compensated PVB with LS schematic A Pp T0 LX P T B LSB LSA 1 0 2 Technical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 125 l min 33 US gal min With turbo function spool max rated flow of 130 l min is possible Technical specification Parameter Minimum Rec...

Page 56: ...00 2000 1000 0 6000 0 0 Load Independent Fluid Flow Pressure Compensated PVB 10 20 30 40 50 60 70 80 90 100 l min US gal min 2 4 6 8 9 12 14 16 18 20 22 24 26 250 225 200 175 150 125 100 75 50 25 0 275 P 2500 2000 1500 1000 500 0 3500 3000 bar psi 110 28 AA B C D A E Q Q Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules 56 Danfoss June 2019 BC290860493426en 000103 ...

Page 57: ...320 400 360 0 psi bar 0 Q 105 110 115 120 27 28 29 30 31 PVLP PVLA PVB pressure compensated for LS A B characteristics 10 20 30 40 50 60 70 80 90 100 l min US gal min 2 4 6 8 10 12 14 16 18 20 22 24 26 110 28 AA B C D A 250 225 200 175 150 125 100 75 50 25 0 350 325 300 275 P P 2500 2000 1500 1000 500 0 3500 3000 4000 5000 4500 bar psi E Q Technical Information PVG EX 32 Proportional Valve Group P...

Page 58: ...ort LS port PVLP PVLA T0 157B6203 G1 2 G1 4 157B6213 Yes 157B6233 Yes 157B6243 Yes Yes 157B6603 7 8 14 UNF 1 2 20 UNF 157B6613 Yes 157B6633 Yes 157B6643 Yes Yes Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules 58 Danfoss June 2019 BC290860493426en 000103 ...

Page 59: ...valve facility PVLP Optional T0 facility Compensated high flow PVB schematic 1 0 2 A B Technical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 130 l min 34 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 3...

Page 60: ...00 2000 1000 0 6000 0 0 Load Independent Fluid Flow Pressure Compensated PVB 10 20 30 40 50 60 70 80 90 100 l min US gal min 2 4 6 8 9 12 14 16 18 20 22 24 26 250 225 200 175 150 125 100 75 50 25 0 275 P 2500 2000 1500 1000 500 0 3500 3000 bar psi 110 28 AA B C D A E Q Q Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules 60 Danfoss June 2019 BC290860493426en 000103 ...

Page 61: ...28 26 24 22 P P 200 160 120 80 40 0 280 240 320 400 360 0 psi bar 0 Q 105 110 115 120 27 28 29 30 31 PVLP PVLA Part numbers for compensated high flow PVB Part number A B port PVLP PVLA LS A B shuttle T0 facility 11091947 7 8 14 UNF Yes Yes Yes 11119463 Yes 11126962 Yes 157B6938 Yes 157B6852 G Yes Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules Danfoss June 2019 BC2908604...

Page 62: ...tle valve for float spool usage External LSA B port connection Optional shock anti cavitation valve facility PVLP Optional T0 facility Compensated high flow PVB with LS A B schematic 1 0 2 A B B LSA LS Technical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 130 l min 34 US gal min Technical specification Parameter Mini...

Page 63: ...00 2000 1000 0 6000 0 0 Load Independent Fluid Flow Pressure Compensated PVB 10 20 30 40 50 60 70 80 90 100 l min US gal min 2 4 6 8 9 12 14 16 18 20 22 24 26 250 225 200 175 150 125 100 75 50 25 0 275 P 2500 2000 1500 1000 500 0 3500 3000 bar psi 110 28 AA B C D A E Q Q Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules Danfoss June 2019 BC290860493426en 000103 63 ...

Page 64: ...320 400 360 0 psi bar 0 Q 105 110 115 120 27 28 29 30 31 PVLP PVLA PVB pressure compensated for LS A B characteristics 10 20 30 40 50 60 70 80 90 100 l min US gal min 2 4 6 8 10 12 14 16 18 20 22 24 26 110 28 AA B C D A 250 225 200 175 150 125 100 75 50 25 0 350 325 300 275 P P 2500 2000 1500 1000 500 0 3500 3000 4000 5000 4500 bar psi E Q Technical Information PVG EX 32 Proportional Valve Group P...

Page 65: ...A B port PVLP PVLA LSA B shuttle T0 facility 157B6855 G G Yes 11059838 Yes 157B6854 Yes 11126963 7 8 14 UNF 20 UNF Yes 11126964 Yes Yes 11127277 Yes Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules Danfoss June 2019 BC290860493426en 000103 65 ...

Page 66: ...ool use Optional thermo relief valve Schematic A B 1 0 2 Technical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 100 l min 26 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 39 SUS 12 to 75 mm2 s 65 to 347...

Page 67: ...C LSA B shuttle Thermo relief 157B6251 G1 2 B port 157B6252 A B port 157B6261 B port Yes 157B6262 A B port Yes 157B6266 A B port Yes Yes 157B6960 A port 157B6651 7 8 14 UNF B port 157B6652 A B port 157B6661 A B port Yes 157B6662 A B port Yes 157B6666 A B port Yes Yes 157B6954 M22x1 5 mm A B port Yes Yes 157B6952 None machined top A B port Yes Yes 157B6958 None machined top A B port Yes Yes 1115708...

Page 68: ...acility Optional LSA B shuttle valve facility for float spool use Optional shock anti cavitation valve facility PVLP Schematic 1 0 2 A B Technical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 125 l min 33 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 6...

Page 69: ... 30 40 50 60 70 80 90 100 l min US gal min 2 4 6 8 9 12 14 16 18 20 22 24 26 250 225 200 175 150 125 100 75 50 25 0 275 P 2500 2000 1500 1000 500 0 3500 3000 bar psi 110 28 AA B C D A E Q Q Part numbers for high flow PVBZ with POC Part number A B port PVLP PVLA LS A B shuttle T0 facility 11119463 7 8 14 UNF Yes 11126962 Yes 157B6938 Yes 157B6852 G Yes Technical Information PVG EX 32 Proportional V...

Page 70: ...leed off Integrated POC T0 facility Integrated adjustable LSA B pressure relief valves Optional thermo relief valve Schematic 1 0 2 1 0 2 A B Technical specification for A B port Max continuous pressure Max intermittent pressure Max rated flow 350 bar 5076 psi 420 bar 6090 psi 125 l min 33 US gal min Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30...

Page 71: ... 22 24 26 250 225 200 175 150 125 100 75 50 25 0 275 P 2500 2000 1500 1000 500 0 3500 3000 bar psi 110 28 AA B C D A E Q Q Part numbers for PVBZ POC manifold interface Part number POC 157B6958 A B port 11005475 A B port 11032961 A B port Technical Information PVG EX 32 Proportional Valve Group PVB Basic Modules Danfoss June 2019 BC290860493426en 000103 71 ...

Page 72: ... from the tank to the work port to prevent cavitation Pressure settings range 32 400 bar 460 5801 psi The pressure setting of the PVLP must always be 20 bar 290 psi higher than LSA B setting in the same module PVLP schematic P109174 Port pressure PVLP shock valve characteristics l min US gal min P Q Q bar psi 20 40 60 80 100 120 140 5 10 15 20 25 30 35 40 45 400 350 300 250 200 150 100 50 0 5000 4...

Page 73: ...28 SUS Fluid cleanliness 23 19 16 according to ISO 4406 Operating temperature Ambient 30 to 60 C 22 to 140 F Part numbers for PVLP according to pressure settings Part number Pressure in bar psi Part number Pressure in bar psi 157B2032 32 464 157B2210 210 3045 157B2050 50 725 157B2230 230 3335 157B2063 63 913 157B2240 240 3480 157B2080 80 1160 157B2250 250 3626 157B2100 100 1450 157B2265 265 3844 1...

Page 74: ...20 21 20 18 16 14 12 10 8 6 4 2 0 85 90 95 100 22 23 24 25 26 Q 28 26 24 22 P P 200 160 120 80 40 0 280 240 320 400 360 0 psi bar 0 Q 105 110 115 120 27 28 29 30 31 PVLP PVLA Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 39 SUS 12 to 75 mm2 s 65 to 347 SUS 460 mm2 s 2128 SUS Fluid cleanliness ...

Page 75: ...to 140 F Flow Control Spools FC Flow control spools are for work sections where you want to control the speed flow of the work port Pressure Control Spools PC Pressure control spools are for work sections where you want to control the power pressure of the work port For more information on where to use flow control or pressure control spools see application guide AB00000079 Using flow or pressure ...

Page 76: ... 7 psi mm PVM in PVE PVH bar psi 11 13 73 218 130 100 160 190 0 5 0 75 0 6 0 55 0 65 0 7 0 1 2 0 0 04 0 08 3 0 12 4 5 6 7 0 16 0 20 0 24 0 28 15 5 11 13 9 7 218 73 160 190 130 100 0 25 0 5 0 35 0 3 0 4 0 45 s UDC 1 8 1 8 1 8 B C E A AA 1 8 1 8 1 8 1 8 B C D E A 8 1 AA U Spool types AA 5 l min A 10 l min B 25 l min C 40 l min D 65 l min E 100 l min 1 First PVB efter PVP 8 Eighth PVB after PVP Techn...

Page 77: ...18 130 100 160 190 0 5 0 75 0 6 0 55 0 65 0 7 0 1 2 0 0 04 0 08 3 0 12 4 5 6 7 0 16 0 20 0 24 0 28 15 5 11 13 9 7 218 73 160 190 130 100 0 25 0 5 0 35 0 3 0 4 0 45 s UDC 1 8 1 8 1 8 B C D E A 8 1 AA U Spool types AA 5 l min A 10 l min B 25 l min C 40 l min D 65 l min E 100 l min 1 First PVB after PVP 8 Eighth PVB after PVP s UDC U 1 8 1 8 1 8 B C D E A 8 1 AA Technical Information PVG EX 32 Propor...

Page 78: ... 5 bar 15 9 7 psi 11 13 73 218 130 100 160 190 15 5 11 13 9 7 218 73 160 190 130 100 PVH in Us UDC V PWM bar psi Linear fluid flow characteristic depending on spool type 10 0 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 20 30 40 50 60 70 80 90 100 l min 2 4 6 8 10 12 14 16 18 20 22 24 26 B P Q mm in mm in Us UDC bar psi B C D E 1 8 1 8 1 8 A P US gal min 2 4 6 8 10 12 14 16 18 20 22 24 26 US gal min 0 75 0 5 0...

Page 79: ...in D 65 l min E 100 l min C D E B C D E B Progressive fluid flow characteristic of spool with B float 10 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 20 30 40 50 60 70 80 90 100 l min 2 4 6 8 10 12 14 16 18 20 22 24 26 B P Q mm in mm in Us UDC bar psi A P US gal min 2 4 6 8 10 12 14 16 18 20 22 24 26 US gal min 0 75 0 5 0 65 0 7 0 6 0 55 PVM PVE 0 5 0 75 0 6 0 55 0 65 0 7 PVH 5 73 5 73 15 9 11 13 218 130 9 130...

Page 80: ...0 40 50 l min US gal min 2 4 6 8 10 12 14 200 160 120 80 40 0 P P 2400 1600 800 0 0 psi 0 Q Q AA D B A C 5 15 25 35 45 55 E T A B 60 bar Pressure drop A B to T in float position 120 l min US gal min 140 20 16 12 8 4 Q ΔP 240 160 80 0 psi bar 0 Q 20 40 60 80 100 120 l min 140 8 8 16 16 24 24 32 32 Q Q US gal min 0 0 T A T B 20 40 60 80 100 Technical Information PVG EX 32 Proportional Valve Group PV...

Page 81: ... 4 100 26 4 100 26 4 157B9503 PVE 2 100 26 4 100 26 4 100 26 4 157B70061 PVE 130 34 3 130 34 3 130 34 3 130 34 3 11137391 PVE Yes 1 0 26 1 0 26 1 0 26 1 0 26 157B7025 PVE Yes 5 1 3 5 1 3 5 1 3 5 1 3 157B7020 PVE Yes 10 2 6 10 2 6 10 2 6 10 2 6 11225588 PVE Yes 15 4 0 15 4 0 15 4 0 15 4 0 157B7021 PVE Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B7022 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B7023 PVE Yes ...

Page 82: ...rt Part numbers for Asymmetric Flow Control Spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157B9524 PVE 5 1 3 5 1 3 10 2 6 10 2 6 11004213 PVE 5 1 3 5 1 3 65 17 2 65 17 2 157B9092 PVE 10 2 6 10 2 6 5 1 3 5 1 3 157B9514 PVE 10 2 6 10 2 6 15 4 0 15 4 0 157B9579 PVE 10 2 6 10 2 6 65 17 2 65 17 2 157B9579 PVE 65 17 2 10 2 6 65 17 2 65 17 2 157B9856 PVE 15 4 0...

Page 83: ...2 6 10 2 6 11066371 PVH PVHC 20 5 3 20 5 3 15 4 0 15 4 0 11130928 PVH PVHC 25 6 6 25 6 6 15 4 0 15 4 0 11130924 PVH PVHC 40 10 6 40 10 6 25 6 6 25 6 6 11130831 PVH PVHC 75 19 8 75 19 8 65 17 2 65 17 2 11094986 PVH PVHC 2 100 26 4 100 26 4 2 11219179 PVH PVHC Yes 40 10 6 40 10 6 25 6 6 25 6 6 157B9084 PVH PVHC Yes 50 13 2 50 13 2 5 1 3 5 1 3 111457411 PVH PVHC Yes 130 34 3 130 34 3 65 17 2 65 17 2 ...

Page 84: ...100 26 4 100 26 4 100 26 4 157B9932 PVE 100 26 4 100 26 4 100 26 4 40 10 6 11129528 PVE Yes 5 1 3 15 4 0 20 5 3 10 2 6 157B9827 PVE Yes 10 2 6 20 5 3 20 5 3 10 2 6 157B9863 PVE Yes 5 1 3 25 6 6 25 6 6 5 1 3 11100489 PVE Yes 5 1 3 25 6 6 40 10 6 20 5 3 157B9946 PVE Yes 25 6 6 25 6 6 10 2 6 10 2 6 157B9858 PVE Yes 10 2 6 40 10 6 40 10 6 10 2 6 157B9639 PVE Yes 25 6 6 40 10 6 40 10 6 25 6 6 157B9906 ...

Page 85: ...ymmetric Flow Control Spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 11020293 PVE Yes 100 26 4 65 17 2 Fully opened no flow restriction notch Technical Information PVG EX 32 Proportional Valve Group PVBS Main Spools Part Numbers Danfoss June 2019 BC290860493426en 000103 85 ...

Page 86: ...bo on A and B port Part numbers for Asymmetric Flow Control Spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157B9911 PVE Yes 30 7 9 30 7 9 65 17 2 65 17 2 157B95181 PVE Yes 100 26 4 100 26 4 65 17 2 100 26 4 1 Turbo on A port Part numbers for Back pressure Flow Control Spools A B T flow track smaller than P A B Part Number Actuation PVB with shuttle valve ...

Page 87: ...157B98241 PVE Yes 100 26 4 100 26 4 100 26 4 100 26 4 1 Turbo on A and B port Flow Control Spools Closed Neutral Position with B float for PVMF Schematic for PVBS with shuttle valve Part numbers for Symmetric Flow Control Spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157B9821 PVE Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B9822 PVE Yes 40 10 6 40 10 6 40 10 6 40...

Page 88: ...701 PVE 25 6 6 25 6 6 25 6 6 25 6 6 157B9702 PVE 40 10 6 40 10 6 40 10 6 40 10 6 157B9703 PVE 65 17 2 65 17 2 65 17 2 65 17 2 157B9704 PVE 100 26 4 100 26 4 100 26 4 100 26 4 157B9725 PVE Yes 5 1 3 5 1 3 5 1 3 5 1 3 157B9720 PVE Yes 10 2 6 10 2 6 10 2 6 10 2 6 157B9721 PVE Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B9722 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B9723 PVE Yes 65 17 2 65 17 2 65 17 2 65 1...

Page 89: ... 2 6 10 2 6 11055532 PVE Yes 35 9 2 35 9 2 65 17 2 65 17 2 11025812 PVE Yes 50 13 2 50 13 2 75 19 8 75 19 8 Back pressure Flow Control Spools A B T flow track smaller than P A B Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 11094317 PVE Yes 2 0 5 5 1 3 5 1 3 2 0 5 11051992 PVE Yes 5 1 3 18 4 8 18 4 8 5 1 3 11027284 PVE Yes 6 1 6 25 6 6 25 6 6 6 1 6 11117573 PVE...

Page 90: ...100 26 4 100 26 4 100 26 4 100 26 4 Part numbers for Asymmetric Flow Control Spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 11201798 PVE Yes 100 26 4 100 26 4 65 17 2 65 17 2 Technical Information PVG EX 32 Proportional Valve Group PVBS Main Spools Part Numbers 90 Danfoss June 2019 BC290860493426en 000103 ...

Page 91: ...00 26 4 100 26 4 100 26 4 11144269 PVE 100 26 4 100 26 4 100 26 4 3 157B90982 PVE 130 34 3 130 34 3 130 34 3 130 34 3 157B71061 PVE 130 34 3 130 34 3 130 34 3 130 34 3 157B9675 PVE Yes 3 0 8 3 0 8 3 0 8 3 0 8 157B7125 PVE Yes 5 1 3 5 1 3 5 1 3 5 1 3 157B7120 PVE Yes 10 2 6 10 2 6 10 2 6 10 2 6 157B9647 PVE Yes 15 4 0 15 4 0 15 4 0 15 4 0 157B9594 PVE Yes 20 5 3 20 5 3 20 5 3 20 5 3 157B7121 PVE Ye...

Page 92: ...21 PVH PVHC Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B9122 PVH PVHC Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B9123 PVH PVHC Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B91242 PVH PVHC Yes 100 26 4 100 26 4 100 26 4 100 26 4 157B91261 PVH PVHC Yes 130 34 3 130 34 3 130 34 3 130 34 3 11201697 PVH PVHC Yes 40 40 40 40 3 Fully opened no flow restriction notch 2 Dead band 0 8 mm 0 03 in 1 Turbo on A and B port Part...

Page 93: ...125125 PVE Yes 40 10 6 40 10 6 65 17 2 65 17 2 157B9505 PVE Yes 40 10 6 40 10 6 100 26 4 100 26 4 11096423 PVE Yes 50 13 2 50 13 2 65 17 2 65 17 2 157B9681 PVE Yes 55 14 5 55 14 5 30 7 9 30 7 9 157B9814 PVE Yes 65 17 2 65 17 2 40 10 6 40 10 6 11217660 PVE Yes 1 80 21 1 80 21 1 1 11202615 PVH PVHC 25 6 6 25 6 6 25 6 6 40 10 6 157B9847 PVH PVHC 30 7 9 30 7 9 20 5 3 20 5 3 157B9546 PVH PVHC 40 10 6 2...

Page 94: ...ure Flow Control Spools A B T flow track smaller than P A B Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 11034321 PVE 3 0 79 3 0 79 10 2 6 1 0 26 11074918 PVE 5 1 3 10 2 6 5 1 3 10 2 6 11006879 PVE 25 6 6 25 6 6 65 17 2 25 6 6 11097891 PVE Yes 40 10 6 100 26 4 40 10 6 40 10 6 157B9684 PVH PVHC 25 6 6 30 7 9 30 7 9 25 6 6 157B9687 PVH PVHC 25 6 6 35 9 2 35 9 2 ...

Page 95: ...00 26 4 100 26 4 100 26 4 100 26 4 157B97161 PVE 130 34 3 130 34 3 130 34 3 130 34 3 157B9735 PVE Yes 5 1 3 5 1 3 5 1 3 5 1 3 157B9730 PVE Yes 10 2 6 10 2 6 10 2 6 10 2 6 157B9731 PVE Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B9732 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B9733 PVE Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B9734 PVE Yes 100 26 4 100 26 4 100 26 4 100 26 4 1 Turbo on A and B port Part numb...

Page 96: ... 157B7421 PVE Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B7422 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B7423 PVE Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B7424 PVE Yes 100 26 4 100 26 4 100 26 4 100 26 4 157B7404 PVH PVHC 100 26 4 100 26 4 100 26 4 100 26 4 157B7424 PVH PVHC Yes 100 26 4 100 26 4 100 26 4 100 26 4 1 Turbo on A and B port 2 Fully opened no flow restriction notch Part numbers for Asymmetri...

Page 97: ...7522 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B7523 PVE Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B7524 PVE Yes 100 26 4 100 26 4 100 26 4 100 26 4 11202731 PVH PVHC Yes 25 6 6 25 6 6 25 6 6 25 6 6 1 Turbo on A and B port Part numbers for Asymmetric Flow Control Spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157B9948 PVE Yes 25 6 6 25 6 6 10 2 6 10 2 6 110...

Page 98: ...26 4 100 26 4 100 26 4 11107159 PVH PVHC Yes 10 2 6 10 2 6 10 2 6 10 2 6 11107222 PVH PVHC Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B9080 PVH PVHC Yes 65 17 2 65 17 2 65 17 2 65 17 2 11083650 PVH PVHC Yes 2 85 17 2 85 17 2 2 1 Dead band 1 1 mm 0 04 in 2 Fully opened no flow restriction notch Part numbers for Asymmetric Flow Control Spools Part Number Actuation PVB with shuttle valve Flow l min US ga...

Page 99: ...40 10 6 40 10 6 40 10 6 40 10 6 11080984 PVH PVHC 65 17 2 65 17 2 65 17 2 65 17 2 11153567 PVH PVHC 100 26 4 40 10 6 40 10 6 100 26 4 112182481 PVH PVHC 130 34 3 130 34 3 130 34 3 130 34 3 157B9806 PVH PVHC Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B9079 PVH PVHC Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B9081 PVH PVHC Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B9082 PVH PVHC Yes 100 26 4 100 26 4 100 26 4 100 ...

Page 100: ...spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 11077423 PVE 5 1 3 5 1 3 157B7200 PVE 10 2 6 10 2 6 157B7201 PVE 25 6 6 25 6 6 157B7202 PVE 40 10 6 40 10 6 157B7203 PVE 65 17 2 65 17 2 157B7204 PVE 100 26 4 100 26 4 11015830 PVE 130 34 3 130 34 3 157B9200 PVH PVHC 10 2 6 10 2 6 157B9201 PVH PVHC 25 6 6 25 6 6 157B9202 PVH PVHC 40 10 6 40 10 6 157B9203 PVH ...

Page 101: ... B T flow track smaller than P A B Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157B9912 PVE 65 17 2 25 6 6 11098878 PVE 25 6 6 5 1 3 11104486 PVH PVHC 25 6 6 5 1 3 Single Acting Cylinder Linear Flow Control Spools Neutral B port Position Schematic for PVBS without shuttle valve Back pressure Flow Control Spool A B T flow track smaller than P A B Part Number A...

Page 102: ...00 26 4 157B9052 PVH PVHC 40 10 6 40 10 6 40 10 6 40 10 6 157B9053 PVH PVHC 65 17 2 65 17 2 65 17 2 65 17 2 157B9054 PVH PVHC 100 26 4 100 26 4 100 26 4 100 26 4 157B9072 PVH PVHC Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B9073 PVH PVHC Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B9074 PVH PVHC Yes 100 26 4 100 26 4 100 26 4 100 26 4 Part numbers for Asymmetric FC PC Spools Part Number Actuation PVB with ...

Page 103: ...7 9 30 7 9 30 7 9 30 7 9 157B7172 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B7173 PVE Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B7174 PVE Yes 100 26 4 100 26 4 100 26 4 100 26 4 11107242 PVH PVHC Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B9173 PVH PVHC Yes 65 17 2 65 17 2 65 17 2 65 17 2 Part numbers for Asymmetric FC PC Control Spools Part Number Actuation PVB with shuttle valve Flow l min US gal min ...

Page 104: ... 2 6 10 2 6 10 2 6 157B7151 PVE 25 6 6 25 6 6 25 6 6 25 6 6 157B7152 PVE 40 10 6 40 10 6 40 10 6 40 10 6 157B7153 PVE 65 17 2 65 17 2 65 17 2 65 17 2 11122525 PVE Yes 10 2 6 10 2 6 10 2 6 10 2 6 157B7562 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B7563 PVE Yes 65 17 2 65 17 2 65 17 2 65 17 2 Part numbers for Asymmetric FC PC Control Spools Part Number Actuation PVB with shuttle valve Flow l min US...

Page 105: ... 6 25 6 6 157B7452 PVE 40 10 6 40 10 6 40 10 6 40 10 6 157B7453 PVE 65 17 2 65 17 2 65 17 2 65 17 2 157B7470 PVE Yes 10 2 6 10 2 6 10 2 6 10 2 6 157B7471 PVE Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B7472 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B7473 PVE Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B9083 PVH PVHC Yes 65 17 2 65 17 2 65 17 2 65 17 2 Part numbers for Asymmetric FC PC Control Spools Part Numb...

Page 106: ...en Closed in Neutral Position All spools have flow control on port A pressure control on port B and a dead band on 1 0 mm 0 04 in Schematic for PVBS without shuttle valve Part number for Back pressure FC PC Spools A B T flow track smaller than P A B Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 11067514 PVE 40 10 6 40 10 6 25 6 6 25 6 6 Flow Pressure Control Sp...

Page 107: ... 8 18 4 8 18 4 8 157B7031 PVE Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B7032 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B7033 PVE Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B9683 PVE Yes 100 26 4 100 26 4 100 26 4 100 26 4 157B9015 PVH PVHC 5 1 3 5 1 3 5 1 3 5 1 3 157B9010 PVH PVHC 10 2 6 10 2 6 10 2 6 10 2 6 157B9540 PVH PVHC 18 4 8 18 4 8 18 4 8 18 4 8 157B9011 PVH PVHC 25 6 6 25 6 6 25 6 6 25 6 6 157B901...

Page 108: ...6 6 25 6 6 25 6 6 25 6 6 157B7132 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B7133 PVE Yes 65 17 2 65 17 2 65 17 2 65 17 2 157B7134 PVE Yes 100 26 4 100 26 4 100 26 4 100 26 4 11057575 PVH PVHC 5 1 3 5 1 3 5 1 3 5 1 3 157B9110 PVH PVHC 10 2 6 10 2 6 10 2 6 10 2 6 157B9112 PVH PVHC 40 10 6 40 10 6 40 10 6 40 10 6 157B9113 PVH PVHC 65 17 2 65 17 2 65 17 2 65 17 2 11057314 PVH PVHC Yes 5 1 3 5 1 3 5 ...

Page 109: ...ls Throttled A to T in Neutral Position Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157B9646 PVE Yes 15 4 15 4 15 4 15 4 157B9199 PVE Yes 10 2 6 10 2 6 40 10 6 40 10 6 Technical Information PVG EX 32 Proportional Valve Group PVBS Main Spools Part Numbers Danfoss June 2019 BC290860493426en 000103 109 ...

Page 110: ...PVH PVHC 25 6 6 25 6 6 25 6 6 25 6 6 157B9042 PVH PVHC 40 10 6 40 10 6 40 10 6 40 10 6 157B9043 PVH PVHC 65 17 2 65 17 2 65 17 2 65 17 2 157B9044 PVH PVHC 100 26 4 100 26 4 100 26 4 100 26 4 157B9062 PVH PVHC Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B9063 PVH PVHC Yes 65 17 2 65 17 2 65 17 2 65 17 2 Part numbers for Asymmetric PC FC Spools Part Number Actuation PVB with shuttle valve Flow l min US g...

Page 111: ... with shuttle valve Flow l min US gal min A T P A P B B T 11122564 PVE 10 2 6 10 2 6 10 2 6 10 2 6 157B7141 PVE 25 6 6 25 6 6 25 6 6 25 6 6 157B7142 PVE 40 10 6 40 10 6 40 10 6 40 10 6 157B7143 PVE 65 17 2 65 17 2 65 17 2 65 17 2 157B7144 PVE 100 26 4 100 26 4 100 26 4 100 26 4 157B7161 PVE Yes 25 6 6 25 6 6 25 6 6 25 6 6 157B7162 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 157B7163 PVE Yes 65 17 2 65...

Page 112: ...0 6 40 10 6 Pressure Flow Control Spools Open Closed A and Closed B Position Schematic for PVBS with shuttle valve Part numbers for Symmetric PC FC Control Spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 11213571 PVE Yes 40 10 6 40 10 6 40 10 6 40 10 6 11198095 PVE Yes 65 17 2 65 17 2 65 17 2 65 17 2 Technical Information PVG EX 32 Proportional Valve Group...

Page 113: ...7 2 65 17 2 65 17 2 11019635 PVE Yes 100 26 4 100 26 4 100 26 4 100 26 4 11105665 PVH PVHC 5 1 3 5 1 3 5 1 3 5 1 3 11105445 PVH PVHC 10 2 6 10 2 6 10 2 6 10 2 6 11105446 PVH PVHC 25 6 6 25 6 6 25 6 6 25 6 6 11125900 PVH PVHC 100 26 4 100 26 4 100 26 4 100 26 4 11140563 PVH PVHC Yes 25 6 6 25 6 6 25 6 6 25 6 6 11140564 PVH PVHC Yes 65 17 2 65 17 2 65 17 2 65 17 2 Part numbers for Back pressure Flow...

Page 114: ...100 26 4 100 26 4 100 26 4 Part numbers for Back pressure Flow Control Spools A B T flow track smaller than P A B Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 11085128 PVE Yes 2 0 5 10 2 6 10 2 6 5 1 3 Part number Flow Control Spools for PVML Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 11128843 PVE Yes 40 10 6 40 10 6 40 ...

Page 115: ...00 26 4 100 26 4 100 26 4 100 26 4 PVBZ Flow Control Spools Throttled Open Neutral Position with B float Schematic for PVBZ with shuttle valve Part number for Symmetric Flow Control Spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157B9690 PVE Yes 15 4 15 4 15 4 15 4 Part number Flow Control Spools for PVML Part Number Actuation PVB with shuttle valve Flow ...

Page 116: ...in US gal min A T P A P B B T 11130939 PVE Yes 25 6 6 40 10 6 40 10 6 25 6 6 Part numbers for Flow Control Spools for PVML Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157B9866 PVE Yes 25 6 6 40 10 6 40 10 6 25 6 6 PVBZ Single Acting Cylinder Flow Control Spools Closed Neutral A port Position Schematic for PVBS without shuttle valve Symmetric flow control spoo...

Page 117: ...ontrol spools Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157B9859 PVE 25 6 6 25 6 6 PVBZ HS Single Acting Cylinder Flow Control Spools Closed Neutral Position Schematic for PVBS with or without shuttle valve Back pressure Flow Control Spools B T flow track smaller than P B Part Number Actuation PVB with shuttle valve Flow l min US gal min A T P A P B B T 157...

Page 118: ...part numbers on electrical EX actuators please see the following documents AN00000349 PVE EX Installation Guide eb mb version Group II AN00000351 PVE EX Installation Guide db version Group I II AN00000365 PVE EX Installation Guide Aex d version BC00000393 PVE EX Technical Information db version eb mb version Technical Information PVG EX 32 Proportional Valve Group PVG EX 32 Actuation 118 Danfoss J...

Page 119: ...VM cover PVM dimensions 185 2 7 29 85 3 35 60 2 36 13 0 51 44 1 73 54 3 2 14 Control lever data No lever position Standard control range Control lever range Control lever range float position 2 x 6 13 4 19 5 22 3 PVM versions torque data Spool displacement PVM PVMD PVM PVE PVM PVH PVM PVMR PVM PVMF From neutral position 2 2 0 2 N m 19 5 1 8 lb in 2 5 0 2 N m 22 1 1 8 lb in 17 N m 3 8 lb in 22 N m ...

Page 120: ... Adjustment screws Lever base Lever base and lever Weight 157B3161 Cast iron Yes Yes 0 4 kg 0 88 lb Technical Information PVG EX 32 Proportional Valve Group PVG EX 32 Actuation 120 Danfoss June 2019 BC290860493426en 000103 ...

Page 121: ...on Covers detailed information Technical data Spool displacement Torque dependent on spool From neutral position PVM PVMD 2 2 0 2 N m 19 5 1 8 lbf in Max spool travel PVM PVMD 2 8 0 2 N m 24 8 1 8 lbf in Part numbers for PVMD F R covers Part number Type Material 157B0021 PVMD Cast iron Technical Information PVG EX 32 Proportional Valve Group PVG EX 32 Actuation Danfoss June 2019 BC290860493426en 0...

Page 122: ... psi Proportional control pressure range 5 15 bar 75 220 psi Operating torque from neutral 2 5 0 2 N m 22 1 1 8 lbf in Operating torque max spool position 6 9 0 2 N m 61 0 1 8 lbf in Part numbers for PVH Hydraulic Actuation Part number Material Weight 157B0014 Cast iron 9 16 18 UNF 157B0016 Cast iron G1 4 Technical Information PVG EX 32 Proportional Valve Group PVG EX 32 Actuation 122 Danfoss June...

Page 123: ...on PVSI The PVSI Start Plates features Integrated LS pressure relief valve to tank Optional integrated thermal orifice Optional version without seals PVSI module PVSI dimensions 109 4 4 31 111 4 37 95 3 74 23 0 91 Weight 0 47 kg 1 05 lb PVSI schematic See part number table for details on maximum pressure capacity Technical data Max rated pressure P port continuous 300 350 bar 4351 5075 psi P port ...

Page 124: ...eals Thermal orifice Mounting 157B2004 350 bar 5076 psi Cast iron 1 745 3 85 Yes 5 16 18 UNC 157B2008 350 bar 5076 psi Cast iron 1 745 3 85 no M8 157B2018 350 bar 5076 psi Cast iron 1 745 3 85 no M8 157B2014 350 bar 5076 psi Cast iron 1 745 3 85 Yes M8 157B2902 350 bar 5076 psi Cast iron 1 745 3 85 Yes Yes 0 8mm M8 For use when using a mid inlet Technical Information PVG EX 32 Proportional Valve G...

Page 125: ...075 psi P port intermittent 400 bar 5800 psi T port static dynamic 25 40 bar 365 580 psi Oil temperature Recommended 30 60 C 86 140 F Minimum 30 C 22 F Maximum 90 194 F Ambient temperature Recommended 30 60 C 22 140 F Oil viscosity Operating range 12 75 mm2 s 65 347 SUS Minimum 4 mm2 s 39 SUS Maximum 460 mm2 s 2128 SUS Oil contamination acc to ISO 4406 Maximum 23 19 16 Part numbers for PVSI with L...

Page 126: ... the PVG EX 32 valve group enables a full flow cut off of the entire valve group by placing the PVSKM right after the PVP inlet module or only a part of the valve group by placing the PVSKM elsewhere in the valve group The PVSKM module variants are based on a generic platform with a wide selection of additional features enabling you to tailor the valve stack to comply with Category 2 or 3 safety s...

Page 127: ...si 400 bar 5800 psi 25 40 bar 365 580 psi Technical specification Parameter Minimum Recommended range Maximum Fluid temperature 30 C 22 F 30 to 60 C 86 to 140 F 90 194 F Fluid viscosity 4 mm2 s 39 SUS 12 to 75 mm2 s 65 to 347 SUS 460 mm2 s 2128 SUS Technical Information PVG EX 32 Proportional Valve Group PVSKM Full Flow Cut Off Modules Danfoss June 2019 BC290860493426en 000103 127 ...

Page 128: ... Operating temperature Ambient 30 to 60 C 22 to 140 F Part number for PVSKM module Part number P port HPCO port T0 Facility Mounting 11099469 G3 4 yes M8 11107369 1 1 16 12 UN yes 11117252 G3 4 Technical Information PVG EX 32 Proportional Valve Group PVSKM Full Flow Cut Off Modules 128 Danfoss June 2019 BC290860493426en 000103 ...

Page 129: ...00 80 60 40 20 0 140 120 0 0 Q Q bar psi Pressure drop from P to HPCO characteristics 2 5 5 7 5 10 12 5 15 bar psi 17 5 20 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 150 135 120 105 90 75 60 45 30 15 0 Q 1500 1200 900 600 300 0 2100 1800 0 US gal min l min 0 P to HPCO 150 l min spool 40 l min spool 100 l min spool Technical Information PVG EX 32 Proportional Valve Group PVSKM Full Flow Cut Off Modules Danfoss ...

Page 130: ...150 l min 39 6 US gal min PVE 11116733 40 l min 10 6 US gal min 11116734 100 l min 26 4 US gal min 11111293 150 l min 39 6 US gal min PVH PVHC Technical Information PVG EX 32 Proportional Valve Group PVSKM Full Flow Cut Off Modules 130 Danfoss June 2019 BC290860493426en 000103 ...

Page 131: ...G valve stack The nuts are tightened at the pump side and at the end plate To find the PVAS kit that fits your PVG EX 32 valve stack you need to go to the table PVG EX 32 modules total length on page 132 and find the length Then go to the table PVAS Part Numbers on page 132 and find the matching part number Technical Information PVG EX 32 Proportional Valve Group PVAS Stay Bolts Danfoss June 2019 ...

Page 132: ...157B8029 205 216 8 07 8 50 157B8003 529 540 20 83 21 26 11188198 217 228 8 54 8 98 11188211 541 552 21 30 21 73 157B8010 229 240 9 02 9 45 157B8023 553 564 21 77 22 20 11188197 241 252 9 49 9 92 11188210 565 576 22 24 22 68 157B8030 253 264 9 96 10 39 157B8004 577 588 22 72 23 15 11188196 265 276 10 43 10 87 11188209 589 600 23 19 23 62 157B8061 277 288 10 91 11 34 157B8024 601 612 23 66 24 09 111...

Page 133: ...U declaration of conformity page 1 EU declaration of conformity page 1 Technical Information PVG EX 32 Proportional Valve Group EU declaration of conformity Danfoss June 2019 BC290860493426en 000103 133 ...

Page 134: ...U declaration of conformity page 2 EU declaration of conformity page 2 Technical Information PVG EX 32 Proportional Valve Group EU declaration of conformity 134 Danfoss June 2019 BC290860493426en 000103 ...

Page 135: ...U declaration of conformity page 3 EU declaration of conformity page 3 Technical Information PVG EX 32 Proportional Valve Group EU declaration of conformity Danfoss June 2019 BC290860493426en 000103 135 ...

Page 136: ...U declaration of conformity page 4 EU declaration of conformity page 4 Technical Information PVG EX 32 Proportional Valve Group EU declaration of conformity 136 Danfoss June 2019 BC290860493426en 000103 ...

Page 137: ...U declaration of conformity page 5 EU declaration of conformity page 5 Technical Information PVG EX 32 Proportional Valve Group EU declaration of conformity Danfoss June 2019 BC290860493426en 000103 137 ...

Page 138: ...Technical Information PVG EX 32 Proportional Valve Group 138 Danfoss June 2019 BC290860493426en 000103 ...

Page 139: ...Technical Information PVG EX 32 Proportional Valve Group Danfoss June 2019 BC290860493426en 000103 139 ...

Page 140: ...Technical Information PVG EX 32 Proportional Valve Group 140 Danfoss June 2019 BC290860493426en 000103 ...

Page 141: ...0 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New District Shanghai China 201206 Phone 86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material Danfos...

Reviews: