![Danfoss PVG 16 PVAS Technical Information Download Page 32](http://html.mh-extra.com/html/danfoss/pvg-16-pvas/pvg-16-pvas_technical-information_507221032.webp)
Open/Closed center PVPM
The Open Center/Closed Center PVPM mid-inlet acts as a simple manifold and is intended for use with
fixed or variable displacement pumps. The PVPM features no logic other than a PVLP shock/anti-
cavitation valve facility for pressure peak protection and anti-cavitation prevention.
The PVPM module must be configured together with an Open Center PVP module for fixed
displacement pumps and for variable displacement pumps can be configured together with a PVSI
start plate or a Closed Center PVP/PVPV module.
The Open center/closed center PVPM features:
•
Integrated shock/anti-cavitation valve facility (PVLP)
•
Threaded ports for P/T
•
Pilot pressure and T0 lines through module
Hydraulic schematic
T
P
Technical specification for PVP
Max. P-port continuous
Max. P-port intermittent
Max. T-port static/
dynamic
Max. rated flow
350 [5076 psi]
400 bar [5800 psi]
25/40 bar [365/580 psi]
140 l/min [37 US gal/min]
Technical specification
Parameter
Minimum
Recommended range
Maximum
Fluid temperature
-30°C [-22°F]
30 to 60°C [86 to 140°F]
90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS]
12 to 75 mm
2
/s [65 to 347 SUS]
460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Part numbers for Open Center/Closed Center PVPM
Part number
P-, T-port
Mounting
PVLP
11093682
1 5/16-12 UN
5/16-18 UNC
Yes
11093684
G1”
M8
Yes
Technical Information
PVG 16 Proportional Valve Group
PVP Inlet Modules
32 |
©
Danfoss | December 2018
BC00000211en-000901