![Danfoss PVG 16 PVAS Technical Information Download Page 20](http://html.mh-extra.com/html/danfoss/pvg-16-pvas/pvg-16-pvas_technical-information_507221020.webp)
Closed Center PVP
The basic Closed Center PVP inlet is intended for use with variable displacement pumps in applications
where a valve group with mechanically controlled work sections is desired, or where the pilot pressure to
the valve group is supplied externally.
The Closed Center PVP features:
•
Integrated LS pressure relief valve
•
Threaded ports for P/T/LS and M measuring gauge
•
Optional LS unloading valve, PVPX
•
Optional T0 facility and external T0 port
Closed center PVP schematic
LS
T
P
M
Technical specification for PVP
Max. P-port continuous
Max. P-port intermittent
Max. T-port static/
dynamic
Max. rated flow
350 [5076 psi]
400 bar [5800 psi]
25/40 bar [365/580 psi]
140 l/min [37 US gal/min]
Technical specification
Parameter
Minimum
Recommended range
Maximum
Fluid temperature
-30°C [-22°F]
30 to 60°C [86 to 140°F]
90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS]
12 to 75 mm
2
/s [65 to 347 SUS]
460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Technical Information
PVG 16 Proportional Valve Group
PVP Inlet Modules
20 |
©
Danfoss | December 2018
BC00000211en-000901