To order the unit, use the following ordering number:

Model

Ordering number

PTU 025, 4 inputs

134B5925

Table 1.2 Ordering Numbers

NOTICE

The PTU 025 unit can be installed in IP55 and IP66
enclosures, and can be connected with the frequency
converter using the C-option interface. This instruction is
applicable for a frequency converter in a standard configu-
ration without any modifications.

Safety Instructions

For important information about safety precautions for installation, refer to the product-specific 

operating guide

.

WARNING

DISCHARGE TIME

The frequency converter contains DC-link capacitors, which can remain charged even when the frequency converter is not
powered. High voltage can be present even when the warning LED indicator lights are off. Failure to wait the specified time
after power has been removed before performing service or repair work can result in death or serious injury.

Stop the motor.

Disconnect AC mains and remote DC-link power supplies, including battery back-ups, UPS, and DC-link connections to
other frequency converters.

Disconnect or lock PM motor.

Wait for the capacitors to discharge fully. The minimum duration of waiting time is specified in 

Table 1.3

.

Before performing any service or repair work, use an appropriate voltage measuring device to make sure that the
capacitors are fully discharged.

Voltage [V]

Minimum waiting time (minutes)

4

7

15

20

30

40

200–240

1.1–3.7 kW

(1.50–5 hp)

5.5–45  kW

(7.5–60 hp)

380–480

1.1–7.5 kW

(1.50–10 hp)

11–90 kW

(15–121 hp)

315–1000 kW

(450–1350 hp)

400

90–315 kW

(121–450 hp)

500

110–355 kW

(150–500 hp)

525

75–315 kW

(100–450 hp)

525–600

1.1–7.5 kW

(1.50–10 hp)

11–90 kW

(15–121 hp)

690

90–315 kW

(100– 350 hp)

525–690

1.1–7.5 kW

(1.50–10 hp)

11–90 kW

(15–121 hp)

400–1400  kW

(500–1550 hp)

450–1400 kW

(600–1550 hp)

Table 1.3 Discharge Time, VLT

®

 HVAC Drive FC 102

Installation Instructions

Pressure Transmitter Unit PTU 025
VLT

®

 HVAC Drive FC 102

2

Danfoss A/S © 12/2017 All rights reserved.

MI08A102

Summary of Contents for PTU 025

Page 1: ...r connection 6 Tube relief plate 3 M25 star washer 7 Interface cable for the C option port 4 M25 gasket 8 Cable binders Table 1 1 Illustration 1 1 Pressure Transmitter Unit PTU 025 and Items Supplied...

Page 2: ...t in death or serious injury Stop the motor Disconnect AC mains and remote DC link power supplies including battery back ups UPS and DC link connections to other frequency converters Disconnect or loc...

Page 3: ...ween the PTU 025 unit and the enclosure This is necessary for the IP55 66 rating 2 Inside the enclosure place the star washer the ground connection and the nut See Illustration 1 3 3 Put the ground wi...

Page 4: ...1 5 2 Wire the outputs for the related signals and statuses 3 Mount the front cover of the frequency converter 4 Power up the frequency converter Ensure that the frequency converter identifies the PT...

Page 5: ...l and relay outputs Perform the configuration in parameter group 5 Main Menu Digital In Out and parameter group 6 Main Menu Analog In Out See the wiring diagram in Illustration 1 6 Illustration 1 6 Wi...

Page 6: ...stration 1 7 Illustration 1 7 Mounting Pressure Tubes NOTICE Put a tube connection on all pressure transmitter taps to minimize the amount of dirt entering the unit The minimum tube length is 80 mm 3...

Page 7: ...fic messages warnings and alarms For more information see the programming guide 31 Pressure Sensor Option Parameters related to the PTU 025 option 31 2 Configuration Each pressure related status has i...

Page 8: ...Sensor 3 Range Function 0 Pa 1000 1000 Pa Shows the readout of pressure sensor 3 31 29 Pressure Sensor 4 Range Function 0 Pa 2500 2500 Pa Shows the readout of pressure sensor 4 31 30 Press Sens Cmp St...

Page 9: ...ors and their Functions Integrating pressure signals into a system solution The pressure values can be read as analog values on the analog output or as pulses on digital outputs Use parameter 5 30 Ter...

Page 10: ...tice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this mat...

Reviews: