The PR-OCTO device is an IoT Enabler specifically designed for cooling applications like bottle coolers, 

ice cream cabinets and other refrigeration type of equipment. This Enabler allows connectivity and 

access to the Alsense™ Cloud solutions from Danfoss.

Electronic thermostats, in general, by monitoring the temperatures and states related to the 

equipment, control the compressor and fan relays and generate warnings and alarms. By means of 

a wired connection, PR-OCTO can obtain from the thermostats diagnostic and alarm data relating 

to the equipment, or create new ones. Thanks to the presence of a modem and an M2M SIM on 

board, PR-OCTO communicates with the Alsense™ monitoring platform through the mobile network, 

transmitting the collected data. PR-OCTO also scans the mobile network and nearby WiFi HotSpots to 

determine its position and transmit it to Alsense™.

If in Alsense™ the refrigeration system is located in a position other than that transmitted by PR-OCTO, 

an alarm is notified on the monitoring platform. Authorized personnel can access Alsense™ to view 

active alarms and decide if PR-OCTO has to lock the operation of the refrigeration system.

Danfoss guarantees a continuous after-sales maintenance of the PR-OCTO devices as they can be 

updated remotely (FOTA) or on site via the mobile app.

1. Introduction

Figure 1 and Figure 2 illustrate the layout of the PR-OCTO device.

See Table 1 for details on the operation.

Fig. 1: Side A

2. Layout

1. Introduction .......................................................................................................................................................................2
2. Layout ..................................................................................................................................................................................2
3. Compatibility .....................................................................................................................................................................4
4.  Connections and wires ..................................................................................................................................................4
5.  Choosing the position in the cooler .........................................................................................................................5
6.  Installation in the coolers .............................................................................................................................................7
7.  Prosa mandatory settings .............................................................................................................................................8
8.  Technical specification ...................................................................................................................................................8
9. Dimensions ........................................................................................................................................................................9
10. Warnings .......................................................................................................................................................................... 10

Content

G

R

Danf

os

s

80G8251

Red LED:

Status of the power supply and the
communication with the electronic thermostat.

Green LED:

Green LED: Status of the mobile connection and
the connection with the Alsense Platform.

Summary of Contents for PR-OCTO

Page 1: ...User Guide Monitoring unit Type PR OCTO IoT Enabler for remote control and tracking of refrigeration equipment...

Page 2: ...WiFi HotSpots to determine its position and transmit it to Alsense If in Alsense the refrigeration system is located in a position other than that transmitted by PR OCTO an alarm is notified on the m...

Page 3: ...is registered to the network The PR OCTO device gives the possibility to execute the lock command and to collect the diagnostic information only in conjunction with an electronic thermostat The curre...

Page 4: ...standard fast on connectors are included in the PR OCTO package Note If the power supply cable is not double insulated it must be physically separated from the COMM cable Concerning the COMM Cable the...

Page 5: ...steps Step 1 Download the VBCTKSignalTester application from this URL http area riservata it vbctksignaltester 1 0 0 setup x86_32 exe Step 2 Install the VBCTKSignalTester application in a Windows PC...

Page 6: ...connector side of the electronic thermostat hence a piece of plastic with an appropriate shape can be used If a piece of plastic is not available a metallic plate can be used but the covered area of...

Page 7: ...detect and manage the door sensor itself For any clarification ask to your local Danfoss agent For the installation the following steps have to be performed Step 1 While the cooler is off put the OCTO...

Page 8: ...to ship the equipment to the final customer Any shipment to the final customer must be notified with an e mail containing the equipment codes and the customer s warehouse address to support prosa dan...

Page 9: ...R OCTO has to be embedded in the cooler and not accessible In case of installation on the back side of the cooler the PR OCTO has to be protected with an additional box to protect people from electric...

Page 10: ...Danfoss Climate Solutions 2022 04 BC391624209008en 000201 10 ADAP KOOL...

Reviews: