Parameter Overview
[22] Ready, no thermal warning
[23] Remote, ready, no thermal
warning
[24] Ready, Voltage OK
[25] Reverse
[26] Bus OK
[35] External Interlock
[45] Bus Control
[60] Comparator 0
[61] Comparator 1
[62] Comparator 2
[63] Comparator 3
[64] Comparator 4
[65] Comparator 5
[70] Logic rule 0
[71] Logic rule 1
[72] Logic rule 2
[73] Logic rule 3
[74] Logic rule 4
[75] Logic rule 5
[80] SL digital output A
[81] SL digital output B
[82] SL digital output C
[83] SL digital output D
[160] No alarm
[161] Running reverse
[165] Local ref. active
[166] Remote ref. active
[167] Start command activ
[168] Drive in hand mode
[169] Drive in auto mode
[193] Sleep Mode
[194] Broken Belt Function
[196] Fire Mode
[198] Drive Bypass
[200] Full capacity
[201] Pump 1 running
[202] Pump 2 running
[203] Pump 3 running
[204] Pump 4 running
[205] Pump 5 running
[211] Cascade Pump 1
[212] Cascade Pump 2
[213] Cascade Pump 3
[214] Cascade Pump 4
[215] Cascade Pump 5
6-93 Terminal 42 Output Min Scale
0.00 - 200.00%, * 0.00
6-94 Terminal 42 Output Max Scale
0.00 - 200.00%, * 100.00
6-96 Terminal 42 Output Bus
Control
0.00 - 100.00%, * 0.00
8-** Comm. and Options
8-0* Comm. General Settings
8-01 Control Site
*[0] Digital and ctrl.word
[1] Digital only
[2] Controlword only
8-02 Control Source
[0] None
*[1] FC Port
8-03 Control Timeout Time
0.1 - 6500.0s, * 1.0
8-04 Control Timeout Function
*[0] Off
[1] Freeze output
[2] Stop
[3] Jogging
[4] Max. speed
[5] Stop and trip
[20] N2 Override Release
8-06 Reset Control Word Timeout
*[0] No function
[1] Do reset
8-3* FC Port Settings
8-30 Protocol
*[0] FC
[2] Modbus RTU
[3] Metasys N2
[4] FLN
[5] BACNet
8-31 Address
1 - 247 , * 1
8-32 FC Port Baud Rate
[0] 2400 Baud
[1] 4800 Baud
*[2] 9600 Baud
[3] 19200 Baud
[4] 38400 Baud
[5] 57600 Baud
[6] 76800 Baud
[7] 115200 Baud
8-33 FC Port Parity
*[0] Even Parity, 1 Stop Bit
[1] Odd Parity, 1 Stop Bit
[2] No Parity, 1 Stop Bit
[3] No Parity, 2 Stop Bits
8-35 Minimum Response Delay
0.001 - 0.500s, * 0.010
8-36 Max Response Delay
0.100 - 10.000s, *5.000
8-37 Max Inter-char delay
0.025 - 0.025s, * 0.025
8-5* Digital/Bus
8-50 Coasting Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-51 Quick Stop Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-52 DC Brake Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-53 Start Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-54 Reversing Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-55 Set-up Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-56 Preset Reference Select
[0] Digital input
[1] Bus
[2] Logic AND
*[3] Logic OR
8-7* Bacnet
8-70 BACnet Device Instance
0 - 0x400000UL
* 1
8-72 MS/TP Maxmaster
0 - 127, * 127
8-73 MS/TP Max Info Frames
1 - 65534, * 1
8-74 "I am" Service
*[0] Send at power-up
[1] Continuously
8-75 Intialisation Password
8-8* FC Port Diagnostics
8-80 Bus Message Count
0 - 65536, * 0
8-81 Bus Error Count
0 - 65536, * 0
8-82 Slave Message Rcvd
0 - 65536, * 0
8-83 Slave Error Count
0 - 65536, * 0
8-84 Slave Message Sent
0 - 65536, * 0
8-85 Slave Timeout Errors
0 - 65536, * 0
8-88 Reset FC port Diagnostics
*[0] Do not reset
[1] Reset counter
8-9* Bus Feedback
8-94 Bus feedback 1
-32768 - 32767, * 0
13-** Smart Logic
13-0* SLC Settings
13-00 SL Controller Mode
*[0] Off
[1] On
13-01 Start Event
[0] False
[1] True
[2] Running
[3] In range
[4] On reference
[7] Out of current range
[8] Below I
low
[9] Above I
high
[16] Thermal warning
[17] Mains out of range
[18] Reversing
[19] Warning
[20] Alarm (trip)
[21] Alarm (trip lock)
[22] Comparator 0
[23] Comparator 1
[24] Comparator 2
[25] Comparator 3
[26] Logic rule 0
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[33] Digital input 18
[34] Digital input 19
[35] Digital input 27
[36] Digital input 29
*[39] Start command
[40] Drive stopped
[41] Reset trip
[42] Auto reset trip
[43] Key Ok
[44] Key Reset
[47] Key Up
[48] Key Down
[50] Comparator 4
[51] Comparator 5
[60] Logic rule 4
[83] Broken belt
13-02 Stop Event
See par. 13-02, *[40] Drive stopped
13-03 Reset SLC
*[0] Do not reset
[1] Reset SLC
13-1* Comparators
13-10 Comparator Operand
*[0] Disabled
[1] Reference