background image

B

K

2

4

3

B

N

B

N

B

N

B

N

1

N2

3A

1

2

-F3

21

22

-K1

95

96

97

98

N1

A1

A2

-K1

8

5

6

11

B

N

*

G

NY

E

B

N

B

K

B

U

B

N

B

K

B

U

P

1

2

PE

-B1*

A1

A2

PE

-Y1

10

MG73BF 

SM500

16 18 15

L1

L2

L3

P

N

26 28 25

-A1

PE

-X1

2

1

-E1*

M

1~

-M2

setting/Einstellung/ajustage -F2

Code

B

K

B

N

G

Y

PE

-X1

M

1~

S

C

R

-M1

-C2

WH

-C1 -R1

R

D

5

2

1

5

-K2

230V1N~/50Hz

L

PE

N

B

N

-F1

B

U

Option

*:

1

2

3

4

5

6

-K1

xxA

5

6

3

4

1

2

-F2

B

U

B

N

B

U

114X7038

OP-

....NTW04

G

114X7049

114X7051

114X7040

114X7073

-R2*

B

N

value

Wert

valeur

Bereich

range

domaine

type/Typ/type

16-24A

19A

20A

16-24A

22A

16-24A

23-32A

25A

26A

23-32A

9-13A

16-24A

11A

17A

OP-MPUE034MLW04G

OP-MPUE046MLW04G

OP-MPME048MTW04G

OP-MPUE057MLW04G

OP-MPME060MTW04G

OP-LPHE048NTW04G

OP-LPHE068NTW04G

114X7053

114X7055

P<

P>

B

C

A

D

PE

-B2

PE

-X1

7

B

N

B

N

B

U

B

U

BK

2

4

3

BN

BN

BN

BN

1

N2

3A

1

2

-F3

21

22

-K1

95

96

97

98

N1

A1

A2

-K1

8

5

6

11

BN

*

G

NYE

BN

BK

BU

BN

BK BU

P

1

2

PE

-B1*

A1

A2

PE

-Y1

10

MG73BF 

SM500

16 18 15

L1

L2

L3

P

N

26 28 25

-A1

PE

-X1

2

1

-E1*

M

1~

-M2

setting/Einstellung/ajustage -F2

Code

BK

BN

GY

PE

-X1

M

1~

S

C

R

-M1

-C2

WH

-C1 -R1

RD

5

2

1

5

-K2

230V1N~/50Hz

L

PE

N

BN

-F1

BU

1

2

3

4

5

6

-K1

xxA

5

6

3

4

1

2

-F2

BU

BN

BU

-R2*

BN

value

Wert

valeur

Bereich

range

domaine

type/Typ/type

P<

P>

B

C

A

D

PE

-B2

PE

-X1

7

BN

BN

BU

BU

S

C

R

114X7042

114X7044

114X7046

OP-MPUE068MLW04G

OP-MPUE080MLW04G

OP-MPUE093MLW04G

23-32A

30-38A

30-40A

32A

38A

40A

Option

*:

Code G  (version W04): OP-MPUE034 - 046 - 057 & OP-MPME048 - 060 & LPHE048 - 068

Code G (version W04): OP-MPUE068 - 080 - 093

Legend
BK black
BU blue
BN brown 
GY grey

RD red
WH white

A1 

Supply & phase reversal protection relay

B1* 

Fan Speed Controller

B2 

DUAL Pressure Switch 

C1 

Start capacitor compressor

C2 

Run capacitor compressor

E1* 

Crankcase heater

F1 

Main switch

F2 

Overload relay

F3 

Fuse control circuit

M1 Compressor
M2 

Fan motor

K1 Contactor

K2 

Start relay

R1, R2 

Bleeder resistor

S1* 

Room thermostat 

X1 Terminals 
Y1* 

Solenoid valve

Instructions

6 |  © Danfoss | DCS (CC) | 2018.07

FRCC.PI.022.B0.02

Summary of Contents for Optyma Slim Pack OP-MPME048

Page 1: ...switch compressors contactor overload relay Crankcase heater OP LPHE units only 2 Handling and storage It is recommended not to open the packaging before the unit is at the final place for installation Handle the unit with care The packaging al lows for the use of a forklift or pallet jack Use appropriate and safe lifting equipment Storeandtransporttheunitinanuprightposition Store the unit between...

Page 2: ...e protection sheet has been re moved from the backside of condenser Balance the High Pressure Low Pressure Energize the unit It must start promptly If the compressor does not start check wiring conformity voltage on terminals and sequence phase Eventual reverse rotation of a 3 phase com pressor can be detected by following phe nomena unit doesn t start the compressor doesn t build up pressure it h...

Page 3: ...OP LPHE067 084 098 OP MPUE068 080 093 099 108 OP LPHE048 068 OP MPUE034 046 057 OP MPME048 060 OP MPZE060 Instructions Danfoss DCS CC 2018 07 3 FRCC PI 022 B0 02 ...

Page 4: ...o LP auto LP man HP man HP man HP auto HP auto P H t e s e r n a m P L t e s e r t u a P L AC1 16 A DC 11 LR 112A AC3 16 A 400 V 12 W AC1110 A 220 V When used acc to UL regulations 1 bar Pe 30in Hg Convertible reset KP 15 15A 17W 17B KP 17B 060 539366 060 539466 LP auto LP auto HP man HP auto Instructions 4 Danfoss DCS CC 2018 07 FRCC PI 022 B0 02 ...

Page 5: ...PRESSOR M T1 T3 T2 3 M1 BU 11 FAN SPEED CONTROLLER P 2 1 B3 BN 12 BN 034 046 069 081 cm 3 DISPLACEMENT 108 048 061 SOLENOID VALVE A1 A2 Y1 BK GY MLZ compr CRANKCASE HEATER MT compr BN BU BN BU 2 1 E1 2 1 E1 Option Q1 F1 K3 K2 S1 T T S2 K3 K2 BN BU P P HIGH PRESSURE LOW PRESSURE B C A D PE B2 MODEL COMPRESSOR MLZ015T4LP9 MLZ021T4LP9 MLZ030T4LC9 MLZ038T4LC9 MLZ048T4LC9 MLZ045T4LC9 MT28 4VM MT36 4VM ...

Page 6: ...2 PE B1 A1 A2 PE Y1 10 MG73BF SM500 16 18 15 L1 L2 L3 P N 26 28 25 A1 PE X1 2 1 E1 M 1 M2 setting Einstellung ajustage F2 Code BK BN GY PE X1 M 1 S C R M1 C2 WH C1 R1 RD 5 2 1 5 K2 230V1N 50Hz L PE N BN F1 BU 1 2 3 4 5 6 K1 xxA 5 6 3 4 1 2 F2 BU BN BU R2 BN value Wert valeur Bereich range domaine type Typ type P P B C A D PE B2 PE X1 7 BN BN BU BU S C R 114X7042 114X7044 114X7046 OP MPUE068MLW04G ...

Page 7: ...eversal protection relay B1 Fan Speed Controller B2 DUAL Pressure Switch B3 Low pressure switch C1 Start capacitor compressor C2 Run capacitor compressor E1 Crankcase heater F1 Main switch F2 Overload relay F3 Fuse control circuit M1 Compressor M2 Fan motor K1 Contactor K2 Start relay R1 R2 Bleeder resistor S1 Room thermostat X1 Terminals Y1 Solenoid valve S1 Instructions Danfoss DCS CC 2018 07 7 ...

Page 8: ...r M2 Fan motor K1 Contactor K2 Start relay R1 R2 Bleeder resistor S1 Room thermostat X1 Terminals Y1 Solenoid valve 8 Danfoss DCS CC 2018 07 FRCC PI 022 B0 02 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alt...

Reviews: