background image

3

8510198 P03-A     © Danfoss Commercial Compressors 03/05

Manual test

Convertible reset
KP 15 060-1154, 060-1220, 060-1261, 060-1263, 060-1 283

LP-man.

LP-auto.

LP-auto.

LP-man.

HP-man.

HP-man.

HP-auto.

HP-auto.

P

H

t

e

s

e

r

 .

n

a

m

 ,

P

L

t

e

s

e

r

 .

t

u

a

 ,

P

L

AC1 16 A

DC 11

LR 112A AC3 16 A 400 V 

12 W

AC1110 A

220 V 

When used acc. to UL regulations

-1 bar (Pe)(30in.Hg)

Convertible reset

KP 15, 15A, 17W, 17B

KP 17B 060-539366, 060-539466 

LP-auto.

LP-auto.

HP-man.

HP-auto.

Instructions

4 |  © Danfoss | DCS (CC) | 2018.07

FRCC.PI.022.B0.02

Summary of Contents for Optyma Slim Pack OP-MPME048

Page 1: ...switch compressors contactor overload relay Crankcase heater OP LPHE units only 2 Handling and storage It is recommended not to open the packaging before the unit is at the final place for installation Handle the unit with care The packaging al lows for the use of a forklift or pallet jack Use appropriate and safe lifting equipment Storeandtransporttheunitinanuprightposition Store the unit between...

Page 2: ...e protection sheet has been re moved from the backside of condenser Balance the High Pressure Low Pressure Energize the unit It must start promptly If the compressor does not start check wiring conformity voltage on terminals and sequence phase Eventual reverse rotation of a 3 phase com pressor can be detected by following phe nomena unit doesn t start the compressor doesn t build up pressure it h...

Page 3: ...OP LPHE067 084 098 OP MPUE068 080 093 099 108 OP LPHE048 068 OP MPUE034 046 057 OP MPME048 060 OP MPZE060 Instructions Danfoss DCS CC 2018 07 3 FRCC PI 022 B0 02 ...

Page 4: ...o LP auto LP man HP man HP man HP auto HP auto P H t e s e r n a m P L t e s e r t u a P L AC1 16 A DC 11 LR 112A AC3 16 A 400 V 12 W AC1110 A 220 V When used acc to UL regulations 1 bar Pe 30in Hg Convertible reset KP 15 15A 17W 17B KP 17B 060 539366 060 539466 LP auto LP auto HP man HP auto Instructions 4 Danfoss DCS CC 2018 07 FRCC PI 022 B0 02 ...

Page 5: ...PRESSOR M T1 T3 T2 3 M1 BU 11 FAN SPEED CONTROLLER P 2 1 B3 BN 12 BN 034 046 069 081 cm 3 DISPLACEMENT 108 048 061 SOLENOID VALVE A1 A2 Y1 BK GY MLZ compr CRANKCASE HEATER MT compr BN BU BN BU 2 1 E1 2 1 E1 Option Q1 F1 K3 K2 S1 T T S2 K3 K2 BN BU P P HIGH PRESSURE LOW PRESSURE B C A D PE B2 MODEL COMPRESSOR MLZ015T4LP9 MLZ021T4LP9 MLZ030T4LC9 MLZ038T4LC9 MLZ048T4LC9 MLZ045T4LC9 MT28 4VM MT36 4VM ...

Page 6: ...2 PE B1 A1 A2 PE Y1 10 MG73BF SM500 16 18 15 L1 L2 L3 P N 26 28 25 A1 PE X1 2 1 E1 M 1 M2 setting Einstellung ajustage F2 Code BK BN GY PE X1 M 1 S C R M1 C2 WH C1 R1 RD 5 2 1 5 K2 230V1N 50Hz L PE N BN F1 BU 1 2 3 4 5 6 K1 xxA 5 6 3 4 1 2 F2 BU BN BU R2 BN value Wert valeur Bereich range domaine type Typ type P P B C A D PE B2 PE X1 7 BN BN BU BU S C R 114X7042 114X7044 114X7046 OP MPUE068MLW04G ...

Page 7: ...eversal protection relay B1 Fan Speed Controller B2 DUAL Pressure Switch B3 Low pressure switch C1 Start capacitor compressor C2 Run capacitor compressor E1 Crankcase heater F1 Main switch F2 Overload relay F3 Fuse control circuit M1 Compressor M2 Fan motor K1 Contactor K2 Start relay R1 R2 Bleeder resistor S1 Room thermostat X1 Terminals Y1 Solenoid valve S1 Instructions Danfoss DCS CC 2018 07 7 ...

Page 8: ...r M2 Fan motor K1 Contactor K2 Start relay R1 R2 Bleeder resistor S1 Room thermostat X1 Terminals Y1 Solenoid valve 8 Danfoss DCS CC 2018 07 FRCC PI 022 B0 02 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alt...

Reviews: