For repair, place the unit in a stable position with the shaft pointing downward. It will be necessary to
secure the pump while removing and torquing end covers, controls, and valves.
Safety Precautions
Always consider safety precautions before beginning a service procedure. Protect yourself and others
from injury. Take the following general precautions whenever servicing a hydraulic system.
Unintended Machine Movement
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders.
Secure the machine or disable/disconnect the mechanism while servicing to protect against unintended
movement.
Flammable Cleaning Solvents
Some cleaning solvents are flammable.
Do not use cleaning solvents in an area where a source of ignition may be present to avoid possible fire.
Fluid Under Pressure
Escaping hydraulic fluid under pressure can have sufficient force to penetrate your skin causing serious
injury and/or infection. This fluid may also be hot enough to cause burns.
Relieve pressure in the system before removing hoses, fittings, gauges, or components. Never use your
hand or any other body part to check for leaks in a pressurized line. Use caution when dealing with
hydraulic fluid under pressure. Seek medical attention immediately if you are cut by hydraulic fluid.
Personal Safety
Protect yourself from injury whenever servicing a hydraulic system.
Use proper safety equipment, including safety glasses, at all times.
Hazardous Material
Hydraulic fluid contains hazardous material.
Avoid prolonged contact with hydraulic fluid. Always dispose of used hydraulic fluid according to state,
and federal environmental regulations.
Symbols used in Danfoss literature
WARNING may result in injury
Tip, helpful suggestion
CAUTION may result in damage to product or
property
Lubricate with hydraulic fluid
Reusable part
Apply grease / petroleum jelly
Non-reusable part, use a new part
Apply locking compound
Non-removable item
Inspect for wear or damage
Option - either part may exist
Clean area or part
Superseded - parts are not interchangeable
Be careful not to scratch or damage
Measurement required
Note correct orientation
Service Manual
MP1
Introduction
©
Danfoss | April 2019