background image

DESCRIPTION

The MCV105C Electrical Displacement Control (EDC) is a
two-stage electrohydraulic pump stroke control which uses
mechanical feedback to establish closed loop control of the
swashplate angle of Danfoss 46 cc Medium Duty
Pumps.

The first stage is a MCV116A torque-motor actuated, double-
nozzle  flapper  valve  that  produces  a  differential  output
pressure proportional to the applied electrical signal.  The
second  stage  uses  the  differential  pressure  to  drive  its
double spool arrangement and port oil to the pump servo
pistons.  The second-stage rotary spool configuration allows
a null deadband (for machine safety) in the pump’s output
while  maintaining  optimum  dynamic  response  to  control
commands.

Single  command  source  can  be  used  to  control  both

hydrostatic pump and motor.

Servo  control  deadband  independent  of  signal  null

deadband:  offers  safety  combined  with  accurate  and
responsive control.

Resistance to the environment:  silicone oil filled torque

motor prevents moisture condensation, environmentally
sealed  first/second  stage  interface,  full  environmental
testing.

Minimum long term null shift.

Pilot  supply  screens  in  series.  Upstream  screen  is

externally serviceable.

Plugged first stage orifice will not drive pump towards full

stroke.

First and second stages can be individually replaced in

the field.

Single or dual coil torque motor.

FEATURES

The standard EDC is a single coil (one input to the torque
motor) Packard connector device.  The first option is a dual
coil, which allows two command sources to be compared at
the torque motor, the resulting signal being the algebraic sum
between  the  two.  Connectors  are  the  second  connector
option  available.  Dual  pilot  coils  are  available  with  both
connector types.  See Wiring, page 8.

All  MCV105C  orifices  will  be  provided  through 
Danfoss, Ames, Iowa.

Order the EDC either factory installed on pumps or as an
individual control.

Order  replacement  parts  through Danfoss,
Minneapolis, MN.  See Table C and D - Service Parts , page
3  to  4,  for  item  number,  part  number  and  description
correspondence.

MCV105C  directly  replaces  MCV105B.  The  MCV105C
housing  is  designed  to  firmly  maintain  the  O-rings  while
mounting. All MCV105C models are factory shipped with O-
rings installed, while the MCV105Bs were not. See Table C

ORDERING INFORMATION

TABLE  A  -  INFORMATION  NECESSARY  TO  SPECIFY
THE EDC.

PILOT STYLE

DESCRIPTION

Single coil, 23 ohm,

22

Packard Weather Pack connector

Dual coil,

23

Packard Weather Pack connector

Single coil, 23 ohm

26

MS connector

Dual coil, 23 ohm

27

MS connector

Single coil, 643 ohm,

46

Packard Weather Pack connector

MCV105C 3 0

XX

STANDARD  EDC CASTING

PILOT STYLE

- Service Parts, page 3, for the appropriate installation kit if
required.

MCV105C

Electrical Displacement Control - MDT

© Danfoss, 2014-05 

11152452 • Rev AA • May 2014

1

Summary of Contents for MCV105C

Page 1: ...ly replaced in the field Single or dual coil torque motor FEATURES The standard EDC is a single coil one input to the torque motor Packard connector device The first option is a dual coil which allows two command sources to be compared at thetorquemotor theresultingsignalbeingthealgebraicsum between the two Connectors are the second connector option available Dual pilot coils are available with bo...

Page 2: ... drive the pilot to full stroke Table B SuggestedVoltageDrives below demonstratesthis relationship and lists the suggested voltage drives for two coil temperatures MAXIMUM CONTINUOUS VOLTAGE THAT WILL NOT DAMAGE THE DEVICE 6 0 Vdc 200 F 93 3 C dual coil 7 5 Vdc 200 F 93 3 C single coil 23 ohm 30 Vdc 200 F 93 3 C single coil 643 ohm COIL INDUCTANCE 0 085 Henries single coil 23 ohm 0 062 Henries A B...

Page 3: ...umber K21436 which includes instructions ITEM PART 1 MCV116A3102 1 PILOT STYLE 22 1 MCV116A3204 1 PILOT STYLE 23 1 MCV116A3101 1 PILOT STYLE 26 1 MCV116A3201 1 PILOT STYLE 27 1 MCV116A3501 1 PILOT STYLE 46 2 K13340 1 LINK COVER 3 K13341 1 COVER GASKET 4 9004101 1190 1 O RING 93 I D X 103 5 K07057 2 SOC HD CAP SCREW 1 4 20 X 5 8 6 K11615 1 HEX SEAL NUT 5 16 24 7 K04064 4 SOC HD CAP SCREW 10 32 X 5 ...

Page 4: ... Silicone Oil Kit 4000 cs 8 K04196 1 Connector Gasket 9 K08687 4 Connector Screw for MS 10 K01314 1 Connector MS 11 K08688 4 Connector Screw for Packard 12 K08106 1 Mating Electrical Connector MS 13 K08014 1 Feed Through Assy Cover Plate 14 K07533 1 Feed Through Assy 4 pin Packard W P 15 K03384 1 Mating Electrical Packard W P 16 K00829 2 O ring control port 17 K00830 1 O ring return port 18 K08573...

Page 5: ...s to 12 15 in lb 16 20 N m 6 Verify that wire to pin connections are correct before soldering wires Also ensure that the connector gasket see Table D Service Parts Item 3 page 4 is in place before soldering 7a For the MS style connector ensure that the cups have sufficient solder approximately level If additional solder is required place solder iron against the base of thecupandaddsolder Whilesold...

Page 6: ...DIA HOLES 002 DRILLED THROUGH 90 APART 5625 18 SAE STR THD O RING BOSS SYSTEM PRESSURE GAUGE PORT A 5625 18 SAE STR THDO RINGBOSS CHARGE PRESSURE GAUGEPORT 5625 18 SAE STR THD O RING BOSS SYSTEM PRESSURE GAUGE PORT B 273 05 10 75 9 65 0 38 72 64 2 86 101 60 4 0 78 23 3 08 79 76 3 14 CAUTION DO NOT ADJUST NULL ON PILOT STAGE USE SECOND STAGE NULL ADJUST DIMENSIONS Dimensions of the MCV105C EDC in m...

Page 7: ... the pilot a stand alone closed loop pressure control valve The second stage of the EDC uses a piston and rotary valve arrangementthatservestoseparatethenulldeadbandfrom the feedback giving both safety against null drift and quick dynamic response to command changes The second stage s null adjust is set with the modulating spring compressed to the equivalent of 12 psi which is the amountofdifferen...

Page 8: ...sed A and B for single coil devices Note device MS connector is not field replaceable Its mate is part number K08106 bag assembly MS3106E 14S 2S See MS Con nectorPinOrientation page9 forproperpinlocations With both designs phasing is such that a positive voltage on the Red wire Pin B will cause a pressure rise at the C2 port for single coil valves The mating Packard connector is part number K03383...

Page 9: ...Crimp location and distance from tang to third rib of Packard Weather Pack Connector Packard Weather Pack interlocked connector halves with parts identified Two wire connector shown CABLE SEALS SIDE B RED BLACK SHROUD CONNECTOR SIDE A DOUBLE PLUG SEAL TOWER CONNECTOR MOUNTING Danfoss Danfoss If there isamanual control mountedonthe pump it must be removed before the MCV105B is mounted To do so Danf...

Page 10: ...uce erratic results 5 Putthe2shortscrews 1 4 20x3 4 throughthebosses onthesideofthevalve Putthetwolongscrews 1 4 20 x 2 5 through the valve body See Dimensions page 6 Torquethefourscrews inacrosspatternstartingwith the bolt closest to the pilot to 10 11 ft lbs Note Impropertorqueingmaycausecontroltobindand produce erratic results 6 If needed install control orifices under both servo covers SLEEVE ...

Page 11: ...lure mode is likely to be one of the following six 1357 Location of one of the servo gauge ports on the pump WARNING Electrical actuation of the valve and or hydraulic jogging of the valve may cause pump output and movement by the driven machine Take precautions to ensure that no personnel are in a position to be injured by the machine if it should move TROUBLESHOOTING FAILURE MODES A NO PUMP OUTP...

Page 12: ...current drive is high enough jog the manual operator on the pilot If full output is attained replacethepilot Ifpumpoutputislowonbothsides ofnull thefiltermaybepluggedinthesecondstage Ifthepumpoutputisfullononesideandlowonthe other replace the pilot F PUMP NULL DEADBAND IS ASYMMETRICAL 1 Adjust the second stage null using the null adjust procedure described previously 2 Iftheproblempersistsandtheno...