MCD Soft Starter Remote Operator

2

MG.17.E2.02 – VLT is a registered Danfoss trademark

Introduction

„

 

Important User Information

Observe all necessary safety precautions

when controlling the soft starter remotely.

Alert personnel that machinery may start

without warning.

It is the installer’s responsibility to follow all

instructions in this manual and to follow correct

electrical practice.

Use all internationally recognised standard practice for

RS485 communications when installing and using this

equipment.

Users are cautioned that the information contained in this

manual is subject to change at any time and without prior

notice. In no event will responsibility or liability be accepted

for direct, indirect or consequential damages resulting from

the use or application of this equipment.

„

 

General Description

The Remote Operator allows remote operation of

MCD 3000

 



 and MCD 200 Series soft starters, and

offers the following functionality:

 

Operational Control (Start, Stop, Quick Stop and

Reset)

 

Starter Status Monitoring (Start, Run and Trip)

 

Performance Monitoring (Motor Current and

Motor Temperature)

 

Trip Code Display

 

4-20 mA Analogue Output (Motor Current)

 

Optional RS485 Network Connection  





The Remote Operator is compatible for use with

MCD 3000 starters with serial numbers

xxxx06-482 or greater.



The Remote Operator can act as a gateway

device for connection to an RS485 serial

communications network, allowing remote

control of a motor from an RS485 serial

communications network using Modbus RTU or

standard AP ASCII communications protocol.

For details, please contact Danfoss and request

a copy of the Modbus Module Operating

Instructions.

„

 

Manual Description

This manual describes the installation, connection,

configuration and operation of the Remote Operator

for use with MCD 3000 and MCD 200 soft starters.

The MCD 200 Series comprises two separate ranges,

MCD 201 and MCD 202. This manual uses the

designation MCD 200 when referring to

characteristics common to both the MCD 201 and

MCD 202 ranges.  In all other cases the text refers to

the specific range MCD 201 or MCD 202.

NB!:

Indicates something to be noted by
the reader.

Indicates a general warning

Summary of Contents for MCD Series

Page 1: ...t User Information 2 General Description 2 Manual Description 2 Installation Installation 3 Mounting 3 Connection 3 Specifications General Technical Data 5 Dimensions 5 Operation Functionality Range 6...

Page 2: ...Stop and Reset Starter Status Monitoring Start Run and Trip Performance Monitoring Motor Current and Motor Temperature Trip Code Display 4 20 mA Analogue Output Motor Current Optional RS485 Network C...

Page 3: ...cutout is 92 x 92 mm Place the Remote Operator through the cutout and locate the mounting bracket at the rear of the panel onto the four studs Use the four fasteners to tighten the mounting bracket up...

Page 4: ...0 Series soft starters a Remote Operator Module must first be installed to the starter using the following steps 1 Remove control power and mains supply from the starter 2 Attach the Remote Operator M...

Page 5: ...ction Terminals B1 B2 B3 3 pole spring clamp connector terminals Analogue Output Motor Current Monitoring Interface 4 20 mA max burden 200 Connection Terminals B10 B11 2 pole spring clamp connector te...

Page 6: ...e Status LEDs Indicate the status of the starter and of the RS485 link between the Remote Operator and the starter Display Mode Denotes the parameter shown on the display Motor Current Motor Temperatu...

Page 7: ...sed in conjunction with MCD 3000 starters with serial numbers between xxxx06 482 and xxxx07 xxx Trip Codes C Communications Failure L FLC Out of Range and Y Incorrect Main Control Module are displayed...

Page 8: ...erator s Motor FLC and Analogue Output 4 mA Offset parameters Parameters 6 and 7 must be set to suit the application Programming can only be carried out while the soft starter is not running Programmi...

Page 9: ...on If communication is restored before the soft starter registers a Communications Failure the display will return to active status and the RS485 LED will illuminate If communication is restored after...

Page 10: ...MCD Soft Starter Remote Operator 10 MG 17 E2 02 VLT is a registered Danfoss trademark Notes...

Page 11: ...MCD Soft Starter Remote Operator MG 17 E2 02 VLT is a registered Danfoss trademark 11 Notes...

Page 12: ...MCD Soft Starter Remote Operator 12 MG 17 E2 02 VLT is a registered Danfoss trademark Notes...

Reviews: