MCD Soft Starter Remote Operator

MG.17.E2.02 – VLT is a registered Danfoss trademark

5

Specifications

„

 

General Technical Data

Enclosure

Front Panel Height   ...................................................................................................................................... 120 mm

Front Panel Width   .....................................................................................................................................   120 mm

Inside Panel Depth (when mounted)   ............................................................................................................   30 mm

Panel Cutout  ..............................................................................................................................................   92 mm

2

Weight   ..........................................................................................................................................................   450 g

Power Supply

Voltage  ..................................................................................................................   18 – 30 VDC or VAC (50/60 Hz)

Consumption   ....................................................................................................................................   250 mA (max)

RS485 Serial Network Port (Optional)

RS485 Network Interface  ................................................................   AP ASCII or Modbus RTU protocol (selectable)

Connection (Terminals B6, B7, B8)  ...........................................................   3 pole spring clamp connector terminals

RS485 Serial Starter Port

RS485 Soft Starter Interface  ....................................................................................   AP ASCII Protocol as standard

Connection (Terminals B1, B2, B3)  ...........................................................   3 pole spring clamp connector terminals

Analogue Output

Motor Current Monitoring Interface  .........................................................................   4 – 20 mA (max burden 200 

)

Connection (Terminals B10, B11) ..............................................................   2 pole spring clamp connector terminals

Environment

Enclosure Rating  ....................................................................................   IP54 or NEMA 12 when correctly installed

Pollution Degree  ........................................................................................................................... Pollution Degree 3

Operating Temperature   ...................................................................................................................  - 5 

o

C / + 60 

o

C

Relative Humidity   ..................................................................................................   5 to 95% (max non condensing)

This product has been designed for Class A equipment. Use of the product in domestic environments may cause

radio interference, in which case the user may be required to employ additional mitigation methods.

Standards Approvals

C

9

   .................................................................................................................................................   IEC 60947-4-2

UL / C-UL   ....................................................................................................................................................  UL 508

CE   ..................................................................................................................................................   IEC 60947-4-2

„

 

Dimensions

177HA266.

11

120

12

0

37.5

7.0

85.0

SOFT STARTER

START

STOP

DATA
PROG

+

RESET

START

RUN

TRIP

RS485

AMPS

TEMP

CODE

Summary of Contents for MCD Series

Page 1: ...t User Information 2 General Description 2 Manual Description 2 Installation Installation 3 Mounting 3 Connection 3 Specifications General Technical Data 5 Dimensions 5 Operation Functionality Range 6...

Page 2: ...Stop and Reset Starter Status Monitoring Start Run and Trip Performance Monitoring Motor Current and Motor Temperature Trip Code Display 4 20 mA Analogue Output Motor Current Optional RS485 Network C...

Page 3: ...cutout is 92 x 92 mm Place the Remote Operator through the cutout and locate the mounting bracket at the rear of the panel onto the four studs Use the four fasteners to tighten the mounting bracket up...

Page 4: ...0 Series soft starters a Remote Operator Module must first be installed to the starter using the following steps 1 Remove control power and mains supply from the starter 2 Attach the Remote Operator M...

Page 5: ...ction Terminals B1 B2 B3 3 pole spring clamp connector terminals Analogue Output Motor Current Monitoring Interface 4 20 mA max burden 200 Connection Terminals B10 B11 2 pole spring clamp connector te...

Page 6: ...e Status LEDs Indicate the status of the starter and of the RS485 link between the Remote Operator and the starter Display Mode Denotes the parameter shown on the display Motor Current Motor Temperatu...

Page 7: ...sed in conjunction with MCD 3000 starters with serial numbers between xxxx06 482 and xxxx07 xxx Trip Codes C Communications Failure L FLC Out of Range and Y Incorrect Main Control Module are displayed...

Page 8: ...erator s Motor FLC and Analogue Output 4 mA Offset parameters Parameters 6 and 7 must be set to suit the application Programming can only be carried out while the soft starter is not running Programmi...

Page 9: ...on If communication is restored before the soft starter registers a Communications Failure the display will return to active status and the RS485 LED will illuminate If communication is restored after...

Page 10: ...MCD Soft Starter Remote Operator 10 MG 17 E2 02 VLT is a registered Danfoss trademark Notes...

Page 11: ...MCD Soft Starter Remote Operator MG 17 E2 02 VLT is a registered Danfoss trademark 11 Notes...

Page 12: ...MCD Soft Starter Remote Operator 12 MG 17 E2 02 VLT is a registered Danfoss trademark Notes...

Reviews: