Index, Sub-Index
Meaning
1048h 0
Number of sub-index supported
1048h 1
Delta speed
1048h 2
Delta time
Table 7.18 6048h vl_velocity_acceleration
7.4.9 6049h vl_velocity_deceleration
The vl_ velocity_deceleration index specifies the slope of
the deceleration ramp. It is generated as the quotient of
the delta_speed and delta_time. The Delta time is stored
in
3-42 Ramp 1 Ramp Down Time
, and the Delta speed is
stored locally in the options non volatile memory. After a
power down the delta speed will be generate from the
frequency converter
1-25 Motor Nominal Speed
. This can
give a different readout from the frequency converter, but
the slope value is maintained.
Index, Sub-Index
Meaning
1049h 0
Number of sub-index supported
1049h 1
Delta speed
1049h 2
Delta time
Table 7.19 6049h vl_velocity_deceleration
7.4.10 604Ch vl_dimension_factor
The vl_dimension_factor configures the numerator and
denominator of the factor. The vl_dimension_factor serves
to include gearing in calculation or serves to scale specific
units of the user. It influences the vl_target_velocity,
vl_velocity_indexes.
Index, Sub-Index
Meaning
104Ch 0
Number of sub-index supported
104Ch 1
Numerator
104Ch 2
Denomerator
Table 7.20 604Ch vl_dimension_factor
7.4.11 6060h Modes of Operation
This index is used for selection the Danfoss FC profile,
MCO profile or the DS 402 profile. The index links directly
to
8-10 Control Word Profile
. If this value is changed while
in operation, the option enters the “Error PREOP” state.
Index, 6060h Value Meaning
-2
MCO profile (only possible if MCO305 is
mounted)
-1
FC Profile
2
DS 402 profile
Table 7.21 6060h Modes of Operation
7.4.12 6061h Modes of Operation Display
This index is used to display which mode the frequency
converter is in. The mode can be changed via index 6060.
The values are the same as used for index 6060.
Index, 6061h Value
Meaning
-1
Default display operation
Table 7.22 6061h Modes of Operation Display
7.4.13 6502h Supported Frequency
Converter Mode
This index informs the user of which operating mode the
frequency converter is capable of. Bit 1 is set, indicating
that the frequency converter can run DS 402 velocity
mode, bit 16 FC profile and 17 indicates MCO profile.
7.4.14 6504h Frequency Converter
Manufacturer
The data is coded as a string.
Emergency Object
This section describes the general layout of the EtherCAT
emergency object. The emergency object is used to signal
error states in the frequency converters to the master. The
frequency converter can be programmed automatically to
send the EMCY object if an alarm or warning is activated.
The frequency converter resends the EMCY object if one of
the alarms or warnings is removed.
Communication Object Overview
The EMCY object always consists of 8 bytes data, see
Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7
EMCY code
Object
1001h
Vendor specific information
See
Reser-
ved
Reser-
ved
Reser-
ved
Reser-
ved
Table 7.23 Communication Object Overview
This index does readout the name of the drive
manufacturer. Data is coded as a string.
Index, sub-index
Meaning
6504Ch 0
Manufacturer “DANFOSS DRIVES”
Table 7.24 6504h Drive Manufacturer (read only)
Communication Profile Area
MCA 124 EtherCAT Operating Instruction
30
MG92A302 - VLT
®
is a registered Danfoss trademark