11
VIIOS202 © Danfoss 07/2017
Installation Guide
Danfoss Link™
DBR
Installation Guide
Danfoss Link™
DBR
Configure settings of the
Danfoss Link
TM
DBR
Setpoint Limits
Configure the Minimum
Temperature and Maximum
temperature for Return Line
setpoint temperatures for
Danfoss Link™
DBR here.
(Note: You can only set these
setpoint limits within the
Dynamic mode.)
The recommended Maximum Temperature is below 54 degrees to
ensure maximum efficiency with condensing boilers.
If Maximum Temperature is set too low, there is a risk of not reaching
the desired temperature.
NL
UK
Green LED OFF
Relay OFF/Standby
Green LED ON
Relay ON/Heating
Green LED fast flash
Adding or link test
Green LED short flash
Ready for adding
Red LED slow flash
Adding not OK
Link test not OK
Safe State Active
Status indicator
Turn off the power to the device, then press and hold the install
button in front of the device for approx. 5 sec. while the power
is switched on again. The button must be held until LED gives a
red flash.
Factory reset
Once the
Danfoss Link™
DBR and all other devices in the system
have been registered and the
Danfoss Link™
CC is placed in
its final position, perform a
network test
(see
separate
Danfoss Link™
CC manual).
Note: If the connection to the Danfoss Link™ CC is
lost for more than 1½ hour, the Danfoss Link™
DBR will go into safety mode. In this mode the
boiler will be turned ON continuously.
Perform network test
FR
Summary of Contents for Link DBR
Page 1: ...Danfoss Heating DanfossLink DynamicBoilerRelay Installation Guide...
Page 13: ...13 VIIOS202 Danfoss 07 2017 Installation Guide Danfoss Link DBR...
Page 34: ...34 VIIOS202 Danfoss 07 2017 Installation Guide Danfoss Link DBR...
Page 35: ...35 VIIOS202 Danfoss 07 2017 Installation Guide Danfoss Link DBR...