22. Mount two bolts in the adapter flange.
23. Mount all bolts in the adapter flange.
Tighten the bolts to a torque of 60±6 Nm.
24. Turn the pump with shaft upwards.
Lubricate the shaft and shaft seal with
clean filtered water. Mount the shaft seal
with the carbon ring upwards.
25. Using the shaft tool provided, carefully
press down the shaft seal to the shoulder of
the shaft.
27. Mount a new O-ring on the flange for shaft
seal and assemble the minor flange on top
of the flange. Tighten bolts to a torque of
30 ±3 Nm.
26. Lubricate and press new ceramic ring into the
shaft seal cover by using the press bush tool.
WARNING:
Ensure that the face with rubber seal is
positioned against shoulder in shaft seal
flange.