16. Assemble the new O-ring on the port
plate-in.
17. Position the port flange in on the adapter
flange and position the two guide pins.
19. Position the guide pin in the adapter
flange.
18. Assemble the new O-ring on the correct
sealing plate.
It is important to lubricate to ensure the
O-ring does not drop out.
20. Position the sealing plate over the guide
pin.
21. Carefully position the adapter flange
assembly into the two guide pin holes.