Options T1D1, T2D2 – electric two-position control with PCOR and electric BPD
T1 – electric two-position 12 V / de-energized = min. displacement
D1 – with PCOR / with electric 12 V BPD, de-energized BPD = PCOR active at port A
T2 – electric two-position 24 V / de-energized = min. displacement
D2 – with PCOR / with electric 24 V BPD, de-energized BPD = PCOR active at port A
A
B
n
min
max
C5
C6
M4
MB
M5
P003435
L1
L1
N
MA
Where:
A, B
Main pressure lines
L1, L2
Drain lines
M4, M5
Gauge port servo pressure
MA, MB
Gauge port system pressure
N
Speed sensor (optional)
Options T1D1, T2D2
Solenoid C6
De-energized = min. displacement
Full-energized = max. displacement
Displacement versus control signal versus PCOR pressure
P003 409
12 V/24 V
6°
32°
PCOR
160 bar
[2321 psi]
300 bar
[4351 psi]
2
1
3
Where:
1
Maximum displacement
2
Minimum displacement
3
Start setting range
Solenoid Data C5 (BPD) and C6 (Two-Position Control)
Description
12 V
24 V
Min. supply voltage
9.5 V
DC
19 V
DC
Max. supply voltage (continuous)
14.6 V
DC
29 V
DC
Nominal coil resistance @ 20 °C [68 °F]
8.4 Ω
34.5 Ω
Recommended input current
1050 mA
500 mA
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
58 |
©
Danfoss | December 2016
11037153 | BC00000043en-US1103