Shaft rotation direction
Shaft rotation direction is determined with a view from the shaft end.
Rotation direction of the motor will be dependent on the control option used as illustrated below.
Controls L1, L2, D1, D2, LH, DH
Direction of rotation
CCW
CW
P006030
B
A
Flow into port A = Clockwise
Flow into port B = CounterClockwise
Controls M1, M2, K1, K2, KH, MH
Direction of rotation
CCW
CW
P006031
B
A
Flow into port A = CounterClockwise
Flow into port B = Clockwise
Controls E1, E2, F1, F2, P1, P2, T1, T2, TA, TH, HE, HF
Direction of rotation
CCW
CW
P006032
B
A
Flow into port A = CounterClockwise
Flow into port B = Clockwise
1)
1 means 12 V
DC
and 2 means 24 V
DC
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Operation
©
Danfoss | December 2016
11037153 | BC00000043en-US1103 | 19