background image

© Danfoss

 

FT1380 Crimp Machine Operator’s Manual

10 | © Danfoss FT1380 Crimp Machine Operator’s Manual | 2022.12. 

 

AQ435955684211en-000101

Troubleshooting Tips

Remember: 

The electric motor only runs during the crimping process. The motor energizes when the crimp switch is pressed and de-energizes when the 

crimp switch is released or when the crimp cycle is completed. While retracting, the hydraulic dump valve is energized. When the valve is energized, oil 
flow is directed from the pump to the cylinder. When the valve is de-energized, oil flows from the cylinder back to the reservoir.

If the symptom appears to be solely pump or cylinder related, refer to the ENERPAC Repair Parts Sheets.  
Any electrical checks must be performed by a qualified electrician.

Symptom

Possible

Cause Corrective Action

Pump will not start

• 

No power or wrong voltage

• 

Make sure that the unit is plugged in.

• 

Make sure that the power source is on.

• 

Make sure that the power voltage is correct.

• 

Check for loose wires on the circuit board.

• 

Check for loose wires on the CRIMP switch.

Motor stalls under load

• 

Low voltage

• 

Verify that the branch circuit conforms to the electrical 
schematics on Page 13 of this manual.

• 

Remove any extension cords.

Electric valve will not operate

• 

No power or wrong voltage

• 

Low voltage

• 

Check for loose wires on the circuit board.

• 

Check for loose wires on the CRIMP switch.

• 

Make sure that the power voltage is correct.

Pump fails to build pressure

• 

External leak in system

• 

Internal leak in pump

• 

Internal leak in valve

• 

Internal leak in system component

• 

Wipe away spilled oil, and locate the source of leak. If 
the hose assembly is leaking, tighten or replace it. If 
the pump or cylinder is leaking, refer to the ENERPAC 
Repair Parts Sheets. Slight oil seepage of the cylinder 
is normal.

Pump builds less than full pressure

• 

Relief valve set low

• 

External system leak

• 

Internal leak in pump

• 

Internal leak in valve

• 

Internal leak in system component

• 

Refer to the ENERPAC Repair Parts Sheets for possible 
adjustment or leakage repair.

Pump builds full pressure, but cylinder 
does not move

• 

Tie rods may be binding

• 

Flow to cylinder blocked

• 

Replace the tie rods.

• 

Refer to the ENERPAC Repair Parts Sheets.

Cylinder will not return

• 

Valve malfunction

• 

Restricted/blocked

• 

Tie rods may be binding

• 

Die cage may be binding

• 

Refer to the ENERPAC Repair Parts Sheet for valve or 
cylinder repair. 

• 

Replace the tie rods.

• 

Check the die cage and crimp ring for damage, and 
repair or replace them if necessary.

• 

Lubricate the die cage per the maintenance 
procedures on Page 9.  

• 

Lubricate the tie rod bushings per the maintenance 
procedures on Page 9.

Crimp diameters change

• 

Incorrect hose/fitting combination

• 

Incorrect die cage

• 

Die cage or crimp insert damage

• 

Transducer is loose

• 

Loose crimp machine components

• 

External damage to crimp machine  

• 

Insufficient lubrication on dies  

• 

Verify the correct hose/fitting combination.

• 

Verify the correct die cage.

• 

Repair or replace the damaged components.

• 

Tighten the transducer and brackets, and then 
recalibrate them if necessary.

• 

Tighten any loose bolts or screws.

• 

Lubricate the die cage per the maintenance 
procedures on Page 9.

• 

Lubricate the tie rod bushings per the maintenance 
procedures on Page 9.

DISPLAY blinks

• 

Loose or broken wires

• 

Tighten any wires that may have become loose on 
the circuit board, pump electrical enclosure, or CRIMP 
switch.

Summary of Contents for FT1380

Page 1: ...Operator s Manual Danfoss FT1380 Crimp Machine CAUTION It is recommended this booklet be read prior to set up then used as a guide during actual assembly Retain for reference purposes...

Page 2: ...Instructions 5 Loading and Unloading Die Cages 5 Operating the Keypad 5 6 Entering a Number into the Display 6 Storing a Number from the Display 6 Recalling a Number from the Display 6 Crimping Proced...

Page 3: ...ke hose assemblies using only Danfoss hose and fittings specified for this assembly equipment 6 Verify correct crimp diameters Check and verify correct crimp diameters of all fittings after crimping D...

Page 4: ...unit 3 CAUTION Failure to do so will cause cavitation and damage to the pumping mechanism Hand tighten the vent cap CAUTION Provide electrical service with a dedicated circuit per the crimp machine e...

Page 5: ...ched the setting entered on the keypad this is when crimp is complete Operating the Keypad 1 The DISPLAY shows the three digit setting that will determine the crimp diameter The ratio of the crimp dia...

Page 6: ...ENTER button will illuminate 3 Press three numerical buttons in less than five seconds If more than five seconds elapse the display reverts back to its previous setting After the third number is enter...

Page 7: ...at any point by momentarily depressing the RETRACT switch and then resumed by depressing and holding the RETRACT switch 5 Verify correct crimp diameter Reminder Full retraction is required for changi...

Page 8: ...g since the numbers are a direct ratio Part II 1 Enter in the value of 400 using the keypad Don t hit enter 2 Center a TTC Z Series 12 fitting without a hose in the die cage holding the socket or fitt...

Page 9: ...ge maintenance should be performed at 1000 crimp intervals or every six months whichever occurs first Die cages should be free of grease and debris and inspected for worn or damaged components a The s...

Page 10: ...ate the source of leak If the hose assembly is leaking tighten or replace it If the pump or cylinder is leaking refer to the ENERPAC Repair Parts Sheets Slight oil seepage of the cylinder is normal Pu...

Page 11: ...rew 8 32 x 3 8 SHCS 8 13 ET4020C 0002 Main Guard 1 14 FT1380 3 5 Transducer Assembly 1 15 FT1380 3 17 Bracket Transducer Rod 1 16 FT1380 3 16 Bracket Transducer 1 17 FT1380 3 21 Nut 2 Detail Part Numb...

Page 12: ...d 1 FT1330 2 9 21 FT1330 2 9 2 FT1330 2 9 21 Die Spring 8 or 16 2 FT1380 2 9 3 FT1380 2 9 2 FT1381 2 9 3 Front Plate 1 3 FT1330 2 9 13 FT1330 2 9 3 FT1330 2 9 13 Spring Plate 1 4 FT1330 2 9 55 FT1330...

Page 13: ...achine Operator s Manual AQ435955684211en 000101 Danfoss FT1380 Crimp Machine Operator s Manual 2022 12 13 Electrical Schematics Electrical Schematic for FT1380 115 115V model Electrical Schematic for...

Page 14: ...ires Black To work light TB2 2 0V AC White From transformer 2 wires White To work light TB1 3 None Green To earth ground TB2 1 4 04V DC Orange To transducer TB2 2 4 04 to 0 04V DC Red To transducer TB...

Page 15: ...s Manual AQ435955684211en 000101 Danfoss FT1380 Crimp Machine Operator s Manual 2022 12 15 Hydraulic Schematic SEQUENCE 1 Pump on Cylinder advances 2 Valve energized Cylinder retracts 3 Pump and valv...

Page 16: ...ss hoses fittings and tooling provide the ultimate fluid conveyance solutions for a variety of equipment and applications around the world We proudly engineer to support a sustainable future for tomor...