Die type
266
Electrical connection
Voltage variant
230 V 50/60 Hz, 3 phases
380 - 420 V 50 Hz, 3 phases
380 - 480 V 60 Hz, 3 phases
Power rating
4 kW
Back-up fuse
230 V: 20 A delayed,
380 - 480 V: 16 A delayed,
preferably thermal fuses, if circuit
breakers are used these should be
of the class C type.
Hydraulic system
Oil volume
approx. 70 l
Oil type
HM 46 or HLP 46, ISO 11158 / ISO
6743-4, 10
filtered
The oil type can be adapted for
specific applications
Viscosity class 68 mm²/s for high-
temperature operating conditions.
Viscosity class 32 mm²/s for low-
temperature operating conditions.
System pressure
max. 330 bar
We recommend industrial flooring meeting the following structu-
ral requirements
Permanent floor loading
Approx. 0.07 kg/mm
2
Floor carrying capacity
Min. 2500 kg/m
2
Floor quality
B25
Evenness
Max. unevenness 5 mm/m
Inclination
max. 5 mm/m