ERC 112
Output
Input
Application
ERC type
DO1
DO2
DO3
DO4
S1
S2
S3
S4
Di
Standard beverage
cooler
ERC 112C
Comp
Fan
Lamp
Control
Defrost
Condenser or Ambient
Light or Motion detection
Door or Motion
detection
Sub-zero beverage
cooler
ERC 112D
Comp
Heater
Fan
Lamp
Control
Defrost
Condenser or Ambient
Light or Motion detection
Door or Motion
detection
Out-door beverage
cooler
ERC 112D
Comp
Heater
Fan
Lamp
Control
Condenser
Ambient Light or Motion
detection
Door or Motion
detection
Nofrost freezer
w. glassdoor
ERC 112D
Comp
Heater
Fan
Lamp
Control
Evaporator
Condenser or Ambient
Light or Motion detection
Door or Motion
detection
CFF refrigerator
ERC 112C
Comp
Fan
Lamp
Control
Defrost
Condenser
Door
CFF freezer
ERC 112D
Comp
Heater
Fan
Lamp
Control
Defrost
Condenser
Door
S: connector position
NOTE:
• Select only one function per input, e.g. condenser sensor or ambient light sensor.
• Make sure that the accessory you select has a matching connector to the input, e.g. a sensor for input "
S2
" must have "
S2
" connector.
• Condenser sensor or light sensor are optional and can be omitted.
• Defrost sensor is mandatory when electrical heater is used for defrost. For natural defrost it can be omitted.
Application Matrix
User Guide | ERC 112 Refrigeration Controller
28 | BC200686422115en-000802